Metrel MD 9050 TRMS Heavy Duty Industrial Digital Multimeter
- Brand
- Metrel
- Model number
- MD 9050
- Category
- Digital Multimeters
Heavy-duty TRMS multimeter rated CAT IV 1000 V: AC, AC+DC and DC voltage and current, autocheck, resistance, conductance, capacitance, K-type temperature and frequency to 1 MHz; backlit dual display.
Price and availability on request
Key features
- TRMS AC, DC voltage measurement
- TRMS AC, DC current measurement
- Capacitance measurement
- Resistance measurement
- Diode test
- Mains supply frequency measurement
- Frequency of digital signals measurement
- Continuity test (acoustic signalling)
- Conductance measurement
- Electric field detection
- Temperature measurement
- TRMS: accurate readings on sinusoidal and non-sinusoidal signals
- Autocheck function: automatic detection of AC voltage, DC voltage or resistance
- Auto-ranging: user can switch between auto and manual ranging
- Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit
- EF detection: non-contact and probe-contact electric field detection
- Lead alert: incorrect lead connection alert
- Relative zero mode: relative function for comparing the difference between signals or removing background noise
- MAX/MIN/AVG: recording of maximum, minimum and average values
- Data Hold: data hold feature freezes the display for later view
- Peak Hold: Crest (instantaneous peak) cupture mode
- PC Link: test results can be downloaded to the computer via the optional PC software
Specifications
| TRMS AC and AC+DC voltage (40 Hz ... 20 kHz) | 60.00 mV ... 999.9 V; from ±(0.5 % of reading + 3 digits) |
|---|---|
| DC voltage | 60.00 mV ... 999.9 V; from ±(0.06 % of reading + 2 digits) |
| Autocheck | ACV / DCV 9.999 V ... 999.9 V; resistance 600.0 Ω ... 60.00 MΩ |
| DC / TRMS AC and AC+DC current | 600.0 µA ... 10.00 A |
| Resistance / conductance | 600.0 Ω ... 60.00 MΩ / 99.99 nS |
| Capacitance | 60.00 nF ... 25.00 mF |
| Temperature | -50 °C ... +1000 °C; ±(0.3 % of reading +2 °C) |
| Frequency (mains / digital) | 15.00 Hz ... 50.00 kHz / 5.00 Hz ... 1.000 MHz |
| Power supply | 9 V battery (NEDA1604G, JIS006P, or IEC6F22) |
|---|---|
| Overvoltage category | CAT IV / 1000 V |
| Dimensions / weight | 208 x 103 x 64.5 mm / 635 g |
| MD 9050 Standard set | Multimeter; MD 9050 with rubber holster; 2 test leads; Thermocouple probe, type K; Battery; User manual; Warranty |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.