Metrel MD 9016 Electrical Field Service Multimeter
- Brand
- Metrel
- Model number
- MD 9016
- Category
- Digital Multimeters
Compact field-service multimeter: AC / DC voltage to 1000 V, current to 10 A, resistance to 60 MΩ, capacitance, K-type temperature to 1000 °C, frequency to 1 MHz, electric field detection and PC link; CAT IV 300 V.
Price and availability on request
Key features
- AC, DC voltage measurement
- AC, DC current measurement
- Capacitance measurement
- Resistance measurement
- Diode test
- Frequency measurement
- Continuity test (acoustic signalling)
- Electric field detection
- Temperature measurement
- Auto-ranging: user can switch between auto and manual ranging
- EF detection: non-contact and probe contact electric field detection
- Relative zero mode: relative function for comparing the difference between signals or removing background noise
- Hold: data hold function freezes the display for later view
- PC Link: test results can be downloaded to the computer via the optional PC software
- Safe: CAT II / 1000 V, CAT III / 600 V and CAT IV / 300 V overvoltage protection
Specifications
| DC voltage | 60.00 mV ... 1000 V; from ±(0.2% of reading + 3 digits) |
|---|---|
| AC voltage (50 Hz ~ 500 Hz) | 60.00 mV ... 1000 V; ±(1.0% of reading + 5 digits) |
| DC / AC current | 600.0 µA ... 10.00 A |
| Resistance | 600.0 Ω ... 60.00 MΩ; from ±(0.5% of reading + 4 digits) |
| Capacitance | 60.00 nF ... 3000 µF |
| Temperature | -50 °C ... 1000 °C; ±(0.3% of reading + 3 digits) |
| Frequency (digital / mains) | 5.00 Hz ... 1.000MHz / 10 Hz ... 50kHz |
| Diode test | Open-circuit voltage < 1.8 V DC, test current 0.56 mA |
| Power supply | 2 x 1.5 V batteries, type AAA |
|---|---|
| Overvoltage category | CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V |
| Dimensions / weight | 161 x 80 x 50 mm / 340 g |
| MD 9016 Standard set | Multimeter; MD 9016 with rubber holster; Test lead with probe, 2 pcs; Thermocouple probe, type K; 1.5 V battery, type AAA, 2 pcs; Instruction manual; Warranty |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.