Masibus UC12 uCAL Universal Calibrator

Brand
Masibus
Model number
UC12

Masibus UC12 uCAL universal calibrator. For laboratory and site calibration purpose, drift test of transmitters and transducers.

Price and availability on request

Request a quote

Sent with the product details: Masibus UC12 uCAL Universal Calibrator.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Compact, handheld, User friendly menu
  • Available with EMI/EMC compliance
  • Easy to read Color Graphical TFT LCD display
  • Rechargeable lithium Ion battery with enhanced power control for prolonged battery life
  • Measure: mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse
  • Source: mA/ V/ mV/ mA(2W)/ Resistance/ RTD/ TC/ Frequency/ Pulse
  • 24 VDC Loop power Supply to power transmitters and loops
  • Step/Ramp functions with Auto/Man selection
  • Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
  • Data Logging to measure long time drift
  • Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), glance screen mode
  • Continuity Test
  • Pulsed RTD transmitter compatible
  • HART loop resistor

Specifications

Specifications
V0 to 30.00 VDC / 0.001 V ; 0 to 12.000 VDC / 0.001 V
mA0 to 24.000 mA / 0.001 mA Electrical Simulation Parameters and Accuracy ; 0 to 24.000 mA / 0.001 mA Thermocouple/mV Measurement /Simulation Resolution and Accuracy
TC TypeRange / Resolution
E-200.0 to 1000.0 °C / 0.1 °C
J-200.0 to 1200.0 °C / 0.1 °C
K-200.0 to 1372.0 °C / 0.1 °C
T-200.0 to 400.0 °C / 0.1 °C
B450.0 to 1800.0 °C / 0.1 °C
R0.0 to 1750.0 °C / 0.1 °C
S0 to 1750.0 °C / 0.1 °C
N-200.0 to 1300.0°C / 0.1 °C
mV-10.000 to 80.000 m / V 0.001 mV; -10.00 to 250.00 m V 0.01mV Note: temperature standard ITS-90
Measurement & Simulation Range
Resistance (Ohms)0 to 400 Ω; 400 to 4000Ω #
Pt10 to Pt1000-200 to 200 °C; 200 to 600 °C; 600 to 850 °C
Ni100-60 to 180 °C
Ni120-80 to 260 °C
Compatible RTD Types
Pt10 (385)Pt400 (385)
Pt50 (385)Pt500 (385)
Pt100 (385)Pt1000 (385)
Pt200 (385)Pt100 (3926) www.masibus.com sales.masibus@soneparindia.com
Hz, KHz, cph, cpm, sec, msec, usec
Ni100 (672)Cu10 (427)
Ni100 (618)Cu50 (427)
Ni120 (672)Cu100 (427)
Product
ApplicationsLaboratory and Site calibration purpose, Drift test of Transmitters and Transducers, Simulation of resistance for position indicators, Sources mV signals for load cell amplifiers, Check flow measurement instruments vide frequency/ pulse parameters

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.