Masibus UC12 uCAL Universal Calibrator
- Brand
- Masibus
- Model number
- UC12
- Category
- Process Calibrators
Masibus UC12 uCAL universal calibrator. For laboratory and site calibration purpose, drift test of transmitters and transducers.
Price and availability on request
Key features
- Compact, handheld, User friendly menu
- Available with EMI/EMC compliance
- Easy to read Color Graphical TFT LCD display
- Rechargeable lithium Ion battery with enhanced power control for prolonged battery life
- Measure: mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse
- Source: mA/ V/ mV/ mA(2W)/ Resistance/ RTD/ TC/ Frequency/ Pulse
- 24 VDC Loop power Supply to power transmitters and loops
- Step/Ramp functions with Auto/Man selection
- Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
- Data Logging to measure long time drift
- Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), glance screen mode
- Continuity Test
- Pulsed RTD transmitter compatible
- HART loop resistor
Specifications
| V | 0 to 30.00 VDC / 0.001 V ; 0 to 12.000 VDC / 0.001 V |
|---|---|
| mA | 0 to 24.000 mA / 0.001 mA Electrical Simulation Parameters and Accuracy ; 0 to 24.000 mA / 0.001 mA Thermocouple/mV Measurement /Simulation Resolution and Accuracy |
| TC Type | Range / Resolution |
| E | -200.0 to 1000.0 °C / 0.1 °C |
| J | -200.0 to 1200.0 °C / 0.1 °C |
| K | -200.0 to 1372.0 °C / 0.1 °C |
| T | -200.0 to 400.0 °C / 0.1 °C |
| B | 450.0 to 1800.0 °C / 0.1 °C |
| R | 0.0 to 1750.0 °C / 0.1 °C |
| S | 0 to 1750.0 °C / 0.1 °C |
| N | -200.0 to 1300.0°C / 0.1 °C |
| mV | -10.000 to 80.000 m / V 0.001 mV; -10.00 to 250.00 m V 0.01mV Note: temperature standard ITS-90 |
| Resistance (Ohms) | 0 to 400 Ω; 400 to 4000Ω # |
|---|---|
| Pt10 to Pt1000 | -200 to 200 °C; 200 to 600 °C; 600 to 850 °C |
| Ni100 | -60 to 180 °C |
| Ni120 | -80 to 260 °C |
| Pt10 (385) | Pt400 (385) |
|---|---|
| Pt50 (385) | Pt500 (385) |
| Pt100 (385) | Pt1000 (385) |
| Pt200 (385) | Pt100 (3926) www.masibus.com sales.masibus@soneparindia.com |
| Ni100 (672) | Cu10 (427) |
|---|---|
| Ni100 (618) | Cu50 (427) |
| Ni120 (672) | Cu100 (427) |
| Applications | Laboratory and Site calibration purpose, Drift test of Transmitters and Transducers, Simulation of resistance for position indicators, Sources mV signals for load cell amplifiers, Check flow measurement instruments vide frequency/ pulse parameters |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.