Masibus LC12 iCAL Loop Calibrator

Brand
Masibus
Model number
LC12

Masibus LC12 iCAL loop calibrator. For loop check and calibration, calibration of transmitters and transducers.

Price and availability on request

Request a quote

Sent with the product details: Masibus LC12 iCAL Loop Calibrator.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Easy to read Color Graphical TFT LCD display
  • Available with EMI/EMC compliance
  • Rechargeable lithium ion battery with enhanced power control for prolonged battery life
  • Simultaneously Measure and Source: mA, mV and V with dual readings on display
  • 24 VDC Loop power Supply to power transmitters and loops
  • 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
  • Step/ Ramp functions with Auto/ Man selection
  • Switch test with condition (open/closed) indicator
  • Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
  • Data Logging to measure long time drift
  • Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off

Specifications

Measurement Range
mV0-250.00 mV / 0.01 mV / +0.02% of reading + 2 counts
V0-30.000 VDC / 0.001 V / +0.02% of reading + 2 counts
mA0-24.000 mA / 0.001 mA / +0.02% of reading + 2 counts
Source Range
mV0-250.00 mV / 0.01 mV / +0.02% of reading + 2 counts
V0-12.000 VDC / 0.001 V / +0.02% of reading + 2 counts
mA0-24.000 mA / 0.001 mA / +0.02% of reading + 2 counts
General Specifications
Display modeMeasure + Source, Measure only, Source only, Switch test + Source
Max. input voltage30 V DC
Temperature coefficient30 ppm
Input impedance MeasureV, mV >1MΩ mA =10 Ω
Response timeInput <100ms Output <100ms
Load impedance>10 KΩ for mV/V <750 Ω for mA
Display update rate10 readings / sec
Isolation500VDC between measure & source
Data loggingLogged data is stored in a user defined file in internal memory Periodic logging: 150000 readings max
Communication InterfaceUSB 2.0
Display and Keys
Display2.4" TFT LCD, 262K Color, Graphical, 42.72 mm x 60.26 mm, 240x320 pixels, White LED backlight
Keys6 Membrane keys
Special Features
Loop power output24V DC, +10% (24mA maximum)
HART mA loop resistor250 Ω + 20%
Special functionStep/Ramp functions: Automatic/Manual, x, x2: for measure & source
Switch testPotential free contacts Trigger level : 24V, 24mA (2V) Voltage level detection Trigger level : 0 to 30V in 1V steps Input impedance : >1 MΩ
Power supply
Battery typeRechargeable Li-ion battery pack, 2300mAh 3.7V
Charging time<5 hours max
Charger supply100-240 VAC, 50/60 Hz; Output 5V DC@1A
Battery life on full charge>18 hours max for mA, mV, V measurement with minimum backlight brightness. > 8 hours max for 12mA generation with minimum backlight brightness
Battery status indicationBattery symbol displayed with % power remaining
Physical
Dimensions (in mm)161.7 (L) x 82.1 (W) x 39.5 (H)
Housing materialABS plastic
Electrical terminalsFour nos., 2 mm safety sockets
Weight<300 grams
ProtectionIP20
Environmental
Operating temperature0 to 55 °C
Operating temperature while charging batteries0 to 45 °C
Storage temperature-200 to 60 °C
Relative humidity30% to 90% non-condensing
Warm-up time15 minutes
En 61326-12013 2014/30/Eu > Low Voltage Directive 2014/68/EU: EN 61010-1:2010 *(Applicable only for CE marked)
Product
ApplicationsLoop Check and calibration, Calibration of Transmitters and Transducers, Switch Test and calibration, Drift test of Transmitters and Transducer, Calibration service provider, Test and maintenance
IndustriesCalibration Lab, Process plant, Dairy plant, Cement Industries, Chemical Industries, Paper Industries, Engineering laboratories, Electronics Industries

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.