Masibus PDA / PDV Programmable AC Current / Voltage Transducer

Brand
Masibus
Model number
PDA / PDV

Masibus PDA / PDV programmable AC current / voltage transducer: input True RMS, accuracy 0.2, output 4-20mA, 0-20mA, 0-10V, 0-5V, 1-5V DC. For generating/transmission distribution stations, building management.

Price and availability on request

Request a quote

Sent with the product details: Masibus PDA / PDV Programmable AC Current / Voltage Transducer.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • High accuracy class 0.2
  • Confirms to IEC 60688
  • True RMS measurement
  • Long range, site-configurable inputs & outputs
  • Onsite selectable output type (DC current / DC voltage)
  • Load-independent accuracy on all outputs
  • Available in single or dual output type
  • Programming port for easy configuration
  • Fast response
  • Excellent long-term stability
  • Good isolation & impulse resistance
  • Transient protected
  • DIN-Rail mounting

Specifications

Specifications
ConfigurationSingle phase
AC Voltage
Nominal Input (Un) (PT Secondary)57.7 V to 415 V
Measuring Voltage Range0 to 130 % Un
Measurement MethodTrue RMS
Burden<0.3VA at Un
PT Ratio1 to 9999.999 programmable on site
Maximum Overload Voltage1.3 x Un continuously 2 x Un for 1 s, with up to 10 repetitions at 10 s intervals
AC Current
Nominal Input (In) (CT Secondary)0 to 1A / 0 to 5A
Measuring Current Range0 to 150 % In
Measurement MethodTrue RMS
Burden<0.2VA at In
CT Ratio1 to 9999.999 programmable on site
Maximum Overload Current2 x In continuously 20 x In for 1 s, with up to 10 repetitions at 100 s intervals
Frequency45 to 65Hz
Analogue output
Accuracy Class0.2
No. of Outputs2
Output Type4-20mA, 0-20mA, 0-10V, 0-5V, 1-5V DC
Maximum Load Resistance≤750 Ω for 20 mA, ≥ 2 k Ω for 10 V (for each output)
Response Time<500mS
Ripple<0.4% peak to peak
Usage GroupI
Standards compliance
StandardsAccuracy as per IEC 60688
Environmental
Operating Temperature0 to +55 C
Storage Temperature-40º to 85°C
Relative Humidity25-95% non-condensing
Warm up Time15 minutes
Installation CategoryCAT III for < 300V AC
Protection ClassII
Pollution Degree2
Ingress ProtectionHousing : IP40, terminals : IP20
Mechanical
Mounting TypeDIN-Rail
Dimension (in mm)71H x 61W x 112D
Case MaterialABS
Weight0.4 Kg
Connector TypeMetal screw
Conductor Size for Terminals ≤ 4 mm2
Communication Ports
Mini USB type For on-site configuration
Product
ApplicationsGenerating/transmission distribution stations, Building management, Load dispatch center, Power equipment's OEMs, HT/LT panels, Substation automation, SCADA, Local and central monitoring systems
IndustriesPower Distribution industries, Cement Industries, Chemical Industries, Metal Industries, Paper Industries, Sugar Industries, Ceramics Industries, Paper and Pulp Industries, Panel Builders

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.