Masibus MFT20 Multifunction Transducer
- Brand
- Masibus
- Model number
- MFT20
Masibus MFT20 multifunction transducer: accuracy Class 0.5 / , Class 0.2, output Open collector. For interface with PLC / SCADA / RTU, remote monitoring and indicating instruments.
Price and availability on request
Key features
- Available in accuracy class 0.5 or 0.2 as per IEC 60688 standard
- Field programmable CT/PT ratio
- True RMS, microcontroller based transducer
- 28 Electrical parameters can be mapped to analogue O/P
- Field programmable up to two analogue output
- Long range, site-configurable inputs and outputs
- Load-independent accuracy on all outputs
- Four quadrant measurement
- RS-485 Modbus-RTU communication protocol
- User assignable Modbus registers
- Energy pulse output
- Maximum demand & THD measurement up to 31st harmonics
- Old register to store the previously cleared energy values
- Last day energy & min. max. value measurement
- Finger touch proof terminals
Specifications
| Specification | Aux. - Powered Model / Self - Powered Model |
|---|---|
| Accuracy Class | Class 0.5 / , Class 0.2 |
| System Type | 3Ph4W / 3Ph3W (Site selectable) |
| Direct Measuring Voltage | 20VL-N to 300VL-N ( 34VL-L to 520VL-L) / 63.5VL-N to 240VL-N |
|---|---|
| PT Secondary (Nominal Voltage-Vn) | 63.5VL-N to 240VL-N |
| Burden | <0.2 VA per phase |
| PT Ratio | Programmable on site |
| Max. Continuous Input Voltage | 1.3 x Nominal value |
| Overload Withstand | 2 x Nominal value for 5 s |
| Accuracy Range | 10% - Vn - 120% [ Minimum voltage is 20V ] / 50% - Vn - 120% [ Minimum voltage is 57.8V ] |
| Direct Measuring Current | 0.01A to 6A |
|---|---|
| Secondary Current (Nominal Current-In) | 1A or 5A |
| Burden | <0.2VA per phase |
| CT Ratio | Programmable on site |
| Max. Continuous Input Current | 2 x Nominal value |
| Overload Withstand | 20 x Nominal value for 1 s |
| Accuracy Range | 10% -In-120% |
| Frequency | 45 to 65 / Hz |
| LED Display (Optional) | 1 line 4 digit 0.32" RED 7-s / egment LED display |
|---|---|
| LCD Display (Optional) | 16x2 Backlight LCD / - |
| Voltage | L1-L2, L2-L3, L1-L3 and average (3Ph3W & 3Ph4W) L1-N, L2-N, L3-N & average (1Ph & 3Ph4W) |
|---|---|
| Current | All phase currents, average, sum, neutral current (3P4W) |
| Frequency | System frequency |
| Power Factor | Phase wise PF & Average PF |
| Phase Angle | Phase wise |
| Power (Phase Wise & Total) | Active power (W, KW & MW) Reactive power (VAR, KVAR & MVAR) Apparent power (VA, KVA & MVA) |
| Energy (Phase Wise & Total) | Active energy for import & export (Separate) (KWh, MWh & GWh) Reactive energy for import & export (Separate) (KVARh, MVARh & GVARh) Reactive Energy Q1, Q2, Q3, Q4, Total Apparent energy (KVAh, MVAh & GVAh) |
| Demand | Maximum power demand on KW/KVA Maximum current demand (Block/Sliding for 15/30 minutes window) |
| Interface | RS-4 / 85 |
| Protocol | Modbus- / RTU |
| Baud Rate | 2400, 4800, 9600, 19200 / , 38400 (Selectable) |
| Parity Bit | None, with 1 or 2 stop bit Odd o / r Even, with 1 or 2 stop bit |
| Assigned Energy Parameter | WH/V / ARH/VAH |
|---|---|
| Pulse Duration | 20 mSec ± 10% |
| Output Type | Open collector |
| Ratings | 24VDC,20mA www.masibus.com sales.masibus@soneparindia.com |
| Applications | Interface with PLC / SCADA / RTU, Remote monitoring and Indicating Instruments, Energy monitoring management system (EMS), Process monitoring & control, Electric utility-generation, transmission and distribution, Control & relay panels, Motor control center panels, Power control center panels, Process control, DG set panels, Original equipment manufacturers (OEMs), HVAC & building management system, HV & LV switchgear panels |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.