Key features
- Available in Accuracy Class 1.0 & Class 0.5s
- True RMS measurement
- Field Programmable CT/PT Primary & Secondary
- Four Quadrant measurement with identification
- Isolated RS485 Modbus Communication (Modbus-RTU protocol)
- Available front Pulse LED for site calibration for selected type of energy
- THD measurement for voltage and current, up to 31st odd harmonics
- Current and power demand monitoring
- Display of minimum and maximum values
- ‘OLD' register to store the previously cleared energy value
- Monitors Run hours & On hours
- Auto Scaling from Kilo to Mega to Giga (LCD Display Only)
- Auto Scrolling feature for easy readability for all parameters
- Favourite page Store feature
- User programmable password protection for Setup mode
Specifications
| Type of Measurement | TRUE RMS |
|---|---|
| Sampling Rate | 82 Samples/Cycle |
| Connection Type | 3P4W / 3P3W / 1P2W (Site selectable) |
| Measuring Voltage Range | 20VL-N to 300VL-N ( 34VL-L to 520VL-L) |
|---|---|
| PT(VT) Primary | 100 V to 1000 KV AC (L-L) (Programmable) |
| Nominal Voltage range (Un) (PT/VT Secondary) | 57.5VL-N to 240VL-N (100VL-L to 415VL-L) |
| Burden | <0.2VA per phase |
| Over Voltage | 120% of Un Continuous |
| Measuring Current Range | 5mA to 6A |
|---|---|
| CT Ratings Primary | 1A/5A to 15000 A (Programmable) |
| Nominal Current range (In) (CT Secondary) | 1A or 5A |
| Burden | 1A: <0.1 VA per phase; 5A: <0.2VA per phase |
| Overload | 150% of In Continuous |
| Short-time Over Current | 20 x Imax for 1 sec., 10 x Imax for 3 sec., 7 x Imax for 10 sec. |
| Suppression Current | A minimum current detection threshold of 1 to 99 mA can be configured to ignore induced or insignificant current flowing in the circuit; 5 mA is the default |
| Frequency 45 to | 65Hz |
| Voltage | ±0.5% / ±0.2% |
|---|---|
| Current | ±0.5% / ±0.2% |
| Frequency | ±0.05% |
| Power Factor | ±0.01 / ± 0.005 |
| Active Power | ±1.0% / ± 0.5% / ± 0.2% |
| Reactive Power | ±1.0% / ± 0.5% |
| Apparent Power | ±1.0% / ± 0.5% / ± 0.2% |
| Active Energy | Class 1 As per IEC 62053-21 / Class 0.5s As per IEC 62053-22 / Class 0.2s As per IEC 62053-22 |
| Reactive Energy | Class 1 As per IEC 62053-24 / Class 0.5s As per IEC 62053-24 |
| Apparent Energy | Class 1.0 / Class 0.5s / Class 0.2s |
| LED Display | LED Display : 3 line 4-digit Red LED Display with 0.56" [ 14.2mm] height, LED Display - 12 digit for energy & 4 digit for Instantaneous parameters |
|---|---|
| Keypad | 3 buttons for navigation to performing configuration setup & Operation |
| Protection Features | Password protected for set-up & clearing energy and Min. / Max. data |
| Green LED Indication | RS485 Communication Activity |
| Red LED | Indication / Energy Pulse |
| Power Supply | Standard: 85-265VAC, 50/60Hz or 100-300VDC Optional: 20-60 VDC |
|---|---|
| Burden | < 3.5VA / <1.5W |
| Operating Temperature | -10°C to +60°C |
|---|---|
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | Up to 95% non-condensing |
| IP degree of Protection | IP51 front side, IP30 meter body |
| Isolation | 4 kV RMS, 1 minute |
| Impulse withstand | 6 kV |
| Pollution Degree | 2 |
| Mounting Type | Panel mount |
|---|---|
| Size | 100(W) x 100(H) x 55(D) mm |
| Panel Cut out | 92(W) x 92(H) mm |
| Material | ABS |
| Accessory | 2 Panel mount clamps |
| Weight | 0.4 kg (Approx.) |
| Terminal & Cable Size | Barrier type terminal U-type / ring-type termination: maximum up to 4 mm2 Cable |
| Interface & Protocol | RS485 Port and Modbus RTU: 2 Wires, Half-duplex |
|---|---|
| Baud Rate | 2400, 4800, 9600, 19200, 38400 bps (Default 9600 bps) |
| Parity Bit | None, Odd, Even with 1 or 2 stop bit |
| Firmware Update | Firmware update through communication port Energy Pulse Output - Optional for LCD Display only |
| Rating | 24VDC, 20mA |
| Pulse Rate | Programmable from 100 to 60000 pulses per Energy |
| Pulse Duration | 20 mSec ± 10% |
| Output Type | Open collector [External Excitation Required] |
| Total Active Power | Rising, Maximum and Maximum Demand Time Stamp* |
|---|---|
| Total Reactive Power | Rising, Maximum and Maximum Demand Time Stamp* |
| Total Apparent Power | Rising, Maximum and Maximum Demand Time Stamp* |
| Average Current | Rising, Maximum and Maximum Demand Time Stamp* |
| Demand Intervals | Programmable from 1 to 60 minutes |
| Demand Calculation Method | Block & Sliding Data Logging - Optional for LCD Display only |
| Method | Periodic Time Based, Load Profile based |
| Time Interval | 1min, 5min,10min,15min, 30min, 45min, 60min, 8h,12h, 24h. |
| Parameters (Programmable up to 34 Parameters) | Voltage, Current, Power Factor, Frequency, Total Power & Energy (Active, Reactive, Apparent) with Time stamp |
| No. of Records | 524288 / ((No of Parameters + 2) * 8) Electromagnetic compatibility (as per IEC 61326-1) |
| Electrostatic Discharge | IEC 61000-4-2 |
| Immunity to Fast transient | IEC 61000-4-4 |
| Immunity to surge waves | IEC 61000-4-5 |
| Immunity to magnetic fields | IEC 61000-4-8 |
| Immunity to voltage dips and interruptions | IEC 61000-4-11 |
| Conducted emissions | CISPR 11 |
| Radiated emissions | CISPR 11 |
| Applications | Commercial and industrial sub-metering, EMS & BMS applications, Electrical installation remote monitoring, High, medium and low-voltage switchgear panels, Panel instrumentation, Power control Centre (PCC) panels, Motor control Centre (MCC) panels, LV distribution panels, Control and relay panels, Automation and monitoring systems |
|---|