Proton 3P ACPM AC Power Monitor, Three Phase

Brand
Proton
Model number
3P ACPM

Meter for measuring and showing electrical parameters (Proton 3P ACPM).

Price and availability on request

Request a quote

Sent with the product details: Proton 3P ACPM AC Power Monitor, Three Phase.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Fully Programmable
  • Complete protection for all unhealthy condition
  • All Set points programmable from keypad
  • Password Protection for controller
  • Different password for each menu set points
  • LCD Display (2X16 Char) with Back Light
  • Good stability, high reliability, and good quality of load
  • Simple 4 keys keypad for on side programming
  • Separate contact for DG
  • Direct display of Line voltage & actual current drawn by load
  • CT Ratio Settable
  • All faults Auto reset
  • D.G. Sensing
  • Fault log History.(last 10Faults)
  • All Menus are Password Protected
  • The AC Power Monitor is a solid state Power Meter
  • Monitoring of single phase AC supply including all types of energies. The AC Power Monitor is based on Microchip, with a high degree of programmability
  • The Meter has been programmed to operate as an intelligent front end measuring and storing device qualifies model AC Power Meter
  • The Meter’s supplied preprogrammed for operation and can be directly installed

Specifications

Specifications
Nominal Voltage Input1] Standard Voltage offered 415 V 3Ph AC(R,Y,B,N) Power supply 2] Accuracy Range: 50 – 115 % of nominal voltage. 3] Burden : < 2.5 VA per phase. 4] Overload: 1.2x nominal continuous
Nominal Input Current5 Amp 1] Accuracy Range for 5 Amps = 120 % nominal. 2] Burden < 0.5 VA per phase. 3] Overload 4.0x nominal continuous 4] Starting current 0.2% of nominal current.
Frequency50 Hz / 60 Hz range (±5 Hz)
Measured Parameters1] RMS Voltage (Volt) (R, Y, B Phase) Phase – Neutral measured. 2] RMS Current (Amps) (R, Y, B Phase) Phase current 3] Frequency (R, Y, B Phase) 4] Power Factor (R, Y, B Phase) 5] Active Power (KVA) (R, Y, B Phase) 6] Apparent Power (KW) (R, Y, B Phase) 7] Main’s KWH 8] DG KWH 9] DG Run hour 10] Mains Run hour
Protection1] Over Voltage Protection (Settable) 2] Under Voltage Protection (Settable) 3] Over Load Protection (Settable) 4] Under Load Protection (Settable) 5] Unbalance voltage/current (Settable) 6] Over Frequency (settable) 7] Over Frequency (settable) 8] Total KW Protection. (Settable) 9] Phase failure protection. (Settable)
Auxiliary PowerNo External power is required (Draws power from the voltage signal Inputs)
Accuracy1] Volt 0.25% ± 1 dgts. 2] Current 0.25% ± 1 dgts. 3] Frequency 0.1% Hz ± 1 dgts. 4] Power Factor 0.25% ± 1 dgts. (for 0.5 Lag – 1.0 - 0.8 Lead) 5] Active Power 0.5% ± 1 dgts. 6] Apparent Power 0.25% ± 1 dgts. 7] Active Energy Class 1.0
Communication Output1] Serial port : RS 485 2] Baud rate : Selectable 1200, 2400, 4800, 9600, 19200. (Default: 9600) 3] Unit No : 1-32 (Default 1) 4] Start bit : 1 5] Stop bit : 1 6] Protocol : MODBUS - RTU
Environmental1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity : 0 – 95 % non-condensive 4] Warm up time : 30 Sec
Enclosure1] Mounting : Panel mounting. 2] Position : Panel. 3] Enclosure : 96 X 96 X 110 mm. 4] Terminal : Screw ON Terminals.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.