Proton 3P ACPM AC Power Monitor, Three Phase
- Brand
- Proton
- Model number
- 3P ACPM
- Category
- Power and Energy Meters
Meter for measuring and showing electrical parameters (Proton 3P ACPM).
Price and availability on request
Key features
- Fully Programmable
- Complete protection for all unhealthy condition
- All Set points programmable from keypad
- Password Protection for controller
- Different password for each menu set points
- LCD Display (2X16 Char) with Back Light
- Good stability, high reliability, and good quality of load
- Simple 4 keys keypad for on side programming
- Separate contact for DG
- Direct display of Line voltage & actual current drawn by load
- CT Ratio Settable
- All faults Auto reset
- D.G. Sensing
- Fault log History.(last 10Faults)
- All Menus are Password Protected
- The AC Power Monitor is a solid state Power Meter
- Monitoring of single phase AC supply including all types of energies. The AC Power Monitor is based on Microchip, with a high degree of programmability
- The Meter has been programmed to operate as an intelligent front end measuring and storing device qualifies model AC Power Meter
- The Meter’s supplied preprogrammed for operation and can be directly installed
Specifications
| Nominal Voltage Input | 1] Standard Voltage offered 415 V 3Ph AC(R,Y,B,N) Power supply 2] Accuracy Range: 50 – 115 % of nominal voltage. 3] Burden : < 2.5 VA per phase. 4] Overload: 1.2x nominal continuous |
|---|---|
| Nominal Input Current | 5 Amp 1] Accuracy Range for 5 Amps = 120 % nominal. 2] Burden < 0.5 VA per phase. 3] Overload 4.0x nominal continuous 4] Starting current 0.2% of nominal current. |
| Frequency | 50 Hz / 60 Hz range (±5 Hz) |
| Measured Parameters | 1] RMS Voltage (Volt) (R, Y, B Phase) Phase – Neutral measured. 2] RMS Current (Amps) (R, Y, B Phase) Phase current 3] Frequency (R, Y, B Phase) 4] Power Factor (R, Y, B Phase) 5] Active Power (KVA) (R, Y, B Phase) 6] Apparent Power (KW) (R, Y, B Phase) 7] Main’s KWH 8] DG KWH 9] DG Run hour 10] Mains Run hour |
| Protection | 1] Over Voltage Protection (Settable) 2] Under Voltage Protection (Settable) 3] Over Load Protection (Settable) 4] Under Load Protection (Settable) 5] Unbalance voltage/current (Settable) 6] Over Frequency (settable) 7] Over Frequency (settable) 8] Total KW Protection. (Settable) 9] Phase failure protection. (Settable) |
| Auxiliary Power | No External power is required (Draws power from the voltage signal Inputs) |
| Accuracy | 1] Volt 0.25% ± 1 dgts. 2] Current 0.25% ± 1 dgts. 3] Frequency 0.1% Hz ± 1 dgts. 4] Power Factor 0.25% ± 1 dgts. (for 0.5 Lag – 1.0 - 0.8 Lead) 5] Active Power 0.5% ± 1 dgts. 6] Apparent Power 0.25% ± 1 dgts. 7] Active Energy Class 1.0 |
| Communication Output | 1] Serial port : RS 485 2] Baud rate : Selectable 1200, 2400, 4800, 9600, 19200. (Default: 9600) 3] Unit No : 1-32 (Default 1) 4] Start bit : 1 5] Stop bit : 1 6] Protocol : MODBUS - RTU |
| Environmental | 1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity : 0 – 95 % non-condensive 4] Warm up time : 30 Sec |
| Enclosure | 1] Mounting : Panel mounting. 2] Position : Panel. 3] Enclosure : 96 X 96 X 110 mm. 4] Terminal : Screw ON Terminals. |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.