Proton 1P ACPM AC Power Monitor, Single Phase
- Brand
- Proton
- Model number
- 1P ACPM
- Category
- Power and Energy Meters
Meter for measuring and showing electrical parameters (Proton 1P ACPM).
Price and availability on request
Key features
- CT Ratio/Gain Configurable
- All Menus are Password Protected
- Different Passwords for each menu set points
- 16 x 2 Line LCD display with Bakelite on controller front panel
- Simple 4 Key keypad for on site programming
- Automatic display of AC Voltages, Current parameters one by one in Run Mode
- Separate contact for DG
- Direct display of Line voltage & actual current drawn by Load
- Run hours for Total Main KWH, Total DG KWH
- D.G. sensing
- Communication with PC given, separate contact for communication TX & RX
- The AC Power Monitor is a solid state Power Meter
- Monitoring of single phase AC supply including all types of energies. The AC Power Monitor is based on Microchip, with a high degree of programmability
- The Meter has been programmed to operate as an intelligent front end measuring and storing device & serial port connectivity qualifies model AC Power Meter
- The Meter’s supplied preprogrammed for operation and can be directly installed. The Meter can be read manually or through a RS-485 MODBUS RTU Protocol.(Optional)
Specifications
| Nominal Voltage Input | -: 1] Standard Voltage offered Single Phase 230 V AC Power supply 2] Accuracy Range : 50 – 115 % of nominal voltage. 3] Burden < 2.5 VA per phase. 4] Overload 1.2x nominal continuous |
|---|---|
| Nominal Input Current | 5 Amp 1] Accuracy Range: For 5 Amps = 120 % nominal. 2] Burden: < 0.5 VA per phase. 3] Overload: 4.0x nominal continuous 4] Starting current: 0.2% of nominal current. |
| Terminals | 1) separate contact for DG. 2) Separate communication terminal. |
| Frequency | 50 Hz / 60 Hz range (±5 Hz). |
| Measured Parameters | 1] RMS Voltage (Volt) Phase – Neutral measured. 2] RMS Current (Amps) Phase current. 3] Frequency. 4] Power Factor. 5] Active Power (KVA). 6] Apparent Power (KW). 7] Main’s KWH. 8] DG KWH. 9] DG Run hour. 10] Mains Run hour. |
| Auxiliary Power | No External power is required (Draws power from the voltage signal |
| Accuracy | 1] Volt: 0.25% ± 1 dgts. 2] Current : 0.25% ± 1 dgts. 3] Frequency: 0.1% Hz ± 1 dgts. 4] Power Factor: 0.25% ± 1 dgts. (For 0.5 Lag – 1.0 - 0.8 Lead) 5] Active Power: 0.5% rdg ± 1 dgts. 6] Apparent Power: 0.25% rdg ± 1 dgts. 7] Active Energy: Class 1.0 |
| Communication Output | 1] Serial port : RS 485 2] Baud rate : Configurable 1200, 2400, 4800, 9600, 19200. (Default: 9600) 3] Unit No : Configurable 1-32 (Default 17) 4] Start bit : 1 5] Stop bit : 1 6] Protocol : MODBUS - RTU |
| Environmental | 1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity : 0 – 95 % non-condensive 4] Warm up time : 30 Sec |
| Enclosure | 1] Mounting : Panel mounting. 2] Position : Panel. 3] Enclosure : 96 X 96 X 110 mm. 4] Terminal : Screw ON Terminals. |
| Key | SET : This key is used to change the controller from RUN mode to FUNCTION mode for parameter setting ENTER: To save the new parameter value INC : Up scroll the parameter & parameter value. DEC : Down scroll the parameter & parameter value. |
| Note | To Load default parameter Press INC key On power ON. |
| Optional features | MODBUS RS-485 RTU protocol connectivity.; GSM Communication to know working status of unit Runflow and fault if any.; Customised sprm can be offerd. |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.