Proton 1P ACPM AC Power Monitor, Single Phase

Brand
Proton
Model number
1P ACPM

Meter for measuring and showing electrical parameters (Proton 1P ACPM).

Price and availability on request

Request a quote

Sent with the product details: Proton 1P ACPM AC Power Monitor, Single Phase.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • CT Ratio/Gain Configurable
  • All Menus are Password Protected
  • Different Passwords for each menu set points
  • 16 x 2 Line LCD display with Bakelite on controller front panel
  • Simple 4 Key keypad for on site programming
  • Automatic display of AC Voltages, Current parameters one by one in Run Mode
  • Separate contact for DG
  • Direct display of Line voltage & actual current drawn by Load
  • Run hours for Total Main KWH, Total DG KWH
  • D.G. sensing
  • Communication with PC given, separate contact for communication TX & RX
  • The AC Power Monitor is a solid state Power Meter
  • Monitoring of single phase AC supply including all types of energies. The AC Power Monitor is based on Microchip, with a high degree of programmability
  • The Meter has been programmed to operate as an intelligent front end measuring and storing device & serial port connectivity qualifies model AC Power Meter
  • The Meter’s supplied preprogrammed for operation and can be directly installed. The Meter can be read manually or through a RS-485 MODBUS RTU Protocol.(Optional)

Specifications

Specifications
Nominal Voltage Input-: 1] Standard Voltage offered Single Phase 230 V AC Power supply 2] Accuracy Range : 50 – 115 % of nominal voltage. 3] Burden < 2.5 VA per phase. 4] Overload 1.2x nominal continuous
Nominal Input Current5 Amp 1] Accuracy Range: For 5 Amps = 120 % nominal. 2] Burden: < 0.5 VA per phase. 3] Overload: 4.0x nominal continuous 4] Starting current: 0.2% of nominal current.
Terminals1) separate contact for DG. 2) Separate communication terminal.
Frequency50 Hz / 60 Hz range (±5 Hz).
Measured Parameters1] RMS Voltage (Volt) Phase – Neutral measured. 2] RMS Current (Amps) Phase current. 3] Frequency. 4] Power Factor. 5] Active Power (KVA). 6] Apparent Power (KW). 7] Main’s KWH. 8] DG KWH. 9] DG Run hour. 10] Mains Run hour.
Auxiliary PowerNo External power is required (Draws power from the voltage signal
Accuracy1] Volt: 0.25% ± 1 dgts. 2] Current : 0.25% ± 1 dgts. 3] Frequency: 0.1% Hz ± 1 dgts. 4] Power Factor: 0.25% ± 1 dgts. (For 0.5 Lag – 1.0 - 0.8 Lead) 5] Active Power: 0.5% rdg ± 1 dgts. 6] Apparent Power: 0.25% rdg ± 1 dgts. 7] Active Energy: Class 1.0
Communication Output1] Serial port : RS 485 2] Baud rate : Configurable 1200, 2400, 4800, 9600, 19200. (Default: 9600) 3] Unit No : Configurable 1-32 (Default 17) 4] Start bit : 1 5] Stop bit : 1 6] Protocol : MODBUS - RTU
Environmental1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity : 0 – 95 % non-condensive 4] Warm up time : 30 Sec
Enclosure1] Mounting : Panel mounting. 2] Position : Panel. 3] Enclosure : 96 X 96 X 110 mm. 4] Terminal : Screw ON Terminals.
KeySET : This key is used to change the controller from RUN mode to FUNCTION mode for parameter setting ENTER: To save the new parameter value INC : Up scroll the parameter & parameter value. DEC : Down scroll the parameter & parameter value.
NoteTo Load default parameter Press INC key On power ON.
Options
Optional featuresMODBUS RS-485 RTU protocol connectivity.; GSM Communication to know working status of unit Runflow and fault if any.; Customised sprm can be offerd.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.