Masibus LC5296-DC Dual Channel Indicator cum Controller

Brand
Masibus
Model number
LC5296-DC

Masibus LC5296-DC dual channel indicator cum controller: input RTD (Pt100), Current, Voltage. For condition monitoring, heat treatment furnaces.

Price and availability on request

Request a quote

Sent with the product details: Masibus LC5296-DC Dual Channel Indicator cum Controller.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Input (RTD, Volts, mA)
  • Fail-safe Design protecting the process in case of system malfunctioning
  • Bright Red seven segment LED Display
  • Display brightness control
  • Status Indication LEDs
  • Relay Output (optional)
  • Retransmission output (optional)
  • RS485 Modbus Communication (optional)
  • Transmitter Power Supply
  • Relay/ retransmission output mapping with respect to input no

Specifications

Input
Input TypeRTD (Pt100), Current, Voltage
Display RangeRefer Table-1
ADC Resolution16 bits
Display Resolution0.1 / 1.0 °C
Sampling Rate2 Samples/Sec
Sensor openAll inputs except 0-5V
Sensor Burnout current0.25uA
RTD excitation current0.166mA (Approx)
NMRR> 40dB
CMRR> 120dB
Temp-co< 150ppm/°C
Input Impedance> 1MΩ
Max Voltage20VDC
Display and Keys
Process Value 1 & 20.56", 7 segment, Red LED, 4 digits
Status LEDsRelay & Communication
KeysSET1, SET2, Increase, Decrease
Control Output
Relays2 Nos.
Rating5A @ 230VAC / 30VDC
Retransmission Output (Optional)
Current0/4-20mA @500Ω Max
Voltage0/1-5V, 0-10V @2KΩ Min
InterfaceRS485
ProtocolModbus-RTU
Baud Rate9600, 19200, 38400
Transmitter Supply*24VDC (±10%) @60mA
Power Supply
Standard85-265VAC/ 125-300VDC
Optional18-36VDC
Physical
Dimensions (mm)96(H) x 96(W) x 75(D)
Front Bezel (mm)96(H) x 96(W)
Panel Cutout (in mm)92 x 92
Depth behind Panel (in mm)65
Weight300g approx.
Enclosure MaterialMolded ABS
Enclosure ProtectionIP20
Terminal Cable Size2.5mm2
Environmental
Operating temperature0-55 °C
Storage temperature0-80 °C
Humidity20-95 %RH non-condensing Table 1: Display Range
InputInput Type / Range
RTDPT-100 (3 wire) / -200 to 850 °C, -199.0 to 850.0 °C
Linear1-5V/0-5V/ 0-10V DC# 0/4-20mA (Ext 250 Ω) / -1999 to 99
Product
ApplicationsCondition Monitoring, Heat treatment furnaces, Water heating boilers, Chillers, Oven control
IndustriesMetal, Cement, Paper, Food Pharma, Power, Oil & Gas, Water

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.