Sound level meter with 3 ranges from 30 to 130 dB, A and C weighting, fast/slow response to IEC 61672 class 2 and AC/DC outputs.

Price and availability on request

Request a quote

Sent with the product details: Lutron SL-4001 Sound Level Meter, IEC 61672 Class 2, AC/DC Output.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Large LCD display, easy to read.
  • Frequency weighting networks are designed to meet the IEC 61672 CLASS 2.
  • A & C weighting networks are conformity to standards.
  • Time weighting(FAST & SLOW) dynamic characteristic modes.
  • AC/DC output for system expansion.
  • Build in adj. VR is available for easy calibration.
  • Condenser microphone for high accuracy & long-term stability.

Specifications

Specifications
Display18mm (0.7") LCD (Liquid Crystal Display), 3 1/2 digits.
Measurement Range3 ranges, 30 to 130 dB, input signal only.
Resolution0.1 dB.
FunctiondB (A & C frequency weighting), Time weighting(Fast, Slow), Max. hold, AC & DC output.
AccuracyFrequency weighting meet IEC 61672-1-2013 class 2, calibrating input signal on 94 dB(31.5 Hz to 8; (23 ± 5 °C) kHz), then the accuracy of frequency weighting is specified as following: 31.5 Hz -reading ± 3.0 dB, 63 Hz -reading ± 2.0 dB, 125 Hz -reading ± 1.5 dB; 250 Hz -reading ± 1.5 dB, 500 Hz -reading ± 1.5 dB, 1 kHz -reading ± 1.0 dB; 2 kHz -reading ± 2.0 dB, 4 kHz -reading ± 3.0 dB, 8 kHz -reading ± 5.0 dB
Frequency Weighting NetworkCharacteristics of A & C.; A weighting - The characteristic is simulated as "Human Ear Listening" response. Typical, if making; the environmental sound level measurement, always select to A weighting.; C weighting - The characteristic is near the "FLAT" response. Typical, it is suitable for checking the; noise of machinery (Q.C. check) & knowing the sound pressure level of the tested; equipment.
Time weightingFast - t= 125 ms, Slow - t = 1 sec.; * "Fast" range is simulated the human ear response time weighting.; "Slow" range is easy to get the average values of vibration sound level.
Range selector30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step; with over & under range indicating.
Frequency31.5 Hz to 8,000 Hz.
Microphone typeElectric condenser microphone.
Microphone size1/2 inch standard size.
CalibratorB & K (Bruel & kjaer), multi-fuction acoustic calibrator, model : 4226.
Operating Temperature0 °C to 50 °C ( 32 °F to 122 °F ).
Operating HumidityLess than 80% RH
Power Supply006P DC 9V battery(heavy duty type).
Weight220 g/0.48 LBS (without battery).
Dimension245 x 80 x 35 mm ( 9.6 x 3.2 x 1.4 inch).
Accessories
Supplied withInstruction Manual: 1 PC; Calibration Screw Driver: 1 PC
Optional94 dB Sound Calibrator, Model : SC-941.; 94 dB/114 dB Sound Calibrator, Model : SC-942.; Hard carrying case, Model : CA-06.
Output Signal
AC output0.5 Vrms corresponding to each range step.
DC output0.3 to 1.3 VDC, 10 mV per dB.
Output impedance600 ohm.
Output terminal3.5 mm phone output terminal.
Technical details
Power ConsumptionApprox. DC 9.5 mA