Lutron CP-200 AC Current Probe, 200 A, for DW-6093 and DW-6095

Brand
Lutron
Model number
CP-200

Small clamp-on AC current probe with 20 A and 200 A ranges and a 19 mm jaw for the DW-6093 and DW-6095 power analyzers; no recalibration on change.

Price and availability on request

Request a quote

Sent with the product details: Lutron CP-200 AC Current Probe, 200 A, for DW-6093 and DW-6095.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Range: 20 A/200 A.
  • Output sensitivity: 10 mV/A, 1 mV/A.
  • Output voltage: 200 ACmV (20 A, 200 A).
  • Max. conductor size: 19 mm (0.75 inch) Dia.
  • Operation frequency: 50 Hz/60 Hz.
  • Optional current probe for DW-6093, DW-6095.
  • When change the new probe, the calibration procedures are not necessary to be executed.
  • Signal output use the banana plugs, durable and safety.

Specifications

Accessories
Supplied withOperating Manual (1 PC)
Measurement Ranges
Autorange20 A, 200 A
Technical details
Output Sensitivity10 mV/A, 1 mV/A
Output Voltage200 ACmV (20 A, 200 A)
Frequency Range45 to 400 Hz
Phase Error< ± 1° (50/60 Hz)
Max. Conductor Size19 mm (0.75 inches) diameter
Operating Frequency50 Hz / 60 Hz
Minimum Load100 K ohm for specified accuracy
Enclosure MaterialUL 94-V0 rated
Safety StandardIEC 1010, Categories III 600V
Power SupplySupplied from DW-6093/DW-6095 (DC 8V ± 1V)
Operating Temperature0°C to 50°C (32°F to 122°F)
HumidityLess than 80% RH
Dimensions179.9 x 66.9 x 40.1 mm (7.0 x 2.6 x 1.57 inches)
Cable Length4 meters (13.1 feet)
Weight330 g (0.73 lb)