Hioki RM3545A-1 Resistance Meter Single Channel

Brand
Hioki
Model number
RM3545A-1

Resistance meter with 1 nΩ resolution and 1 A testing current, measuring 1 nΩ to 1200 MΩ with OVC and temperature correction; probe sold separately. Single-channel model.

Price and availability on request

Request a quote

Sent with the product details: Hioki RM3545A-1 Resistance Meter Single Channel.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 0.045% basic accuracy, 1 nΩ max. resolution, 1A max. testing current
  • Measure from 1 nΩ (testing current 1 A) to 1200 MΩ
  • Equipped with advanced features, ensuring precise resistance measurement (OVC, temperature measurement, and correction function)
  • High path resistance tolerance allows seamless integration into an automatic test system, eliminating concerns about wiring or contact resistance
  • Advanced contact-check, comparator function, control, and communications features

Specifications

Specifications
Resistance range (13 ranges)[Range, Maximum display value, Resolutions, Testing current (Measurement current) ] 1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A 10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A 100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A 1000 mΩ: 1200.000 mΩ, 1 μΩ, 100 mA 10 Ω: 12.000 00 Ω, 10 μΩ, 10 mA 100 Ω: 120.000 0 Ω, 100 μΩ, 10 mA 1000 Ω: 1200.000 Ω, 1 mΩ, 1 mA 10 kΩ: 12.000 00 kΩ, 10 mΩ, 1 mA 100 kΩ: 120.000 0 kΩ, 100 mΩ, 100 μA 1000 kΩ: 1200.000 kΩ, 1 Ω, 10 μA 10 MΩ 12.000 00 MΩ, 10 Ω, 1 μA 100 MΩ (100 MΩ range high-precision mode): 120.000 0
Representative accuracy(High mode, OVC function enabled, SLOW2, no zero adjustment) 1000 μΩ range: ±0.045% rdg ±0.010 % f.s. 10 mΩ range: ±0.045% rdg ±0.001 % f.s. 100 mΩ range: ±0.045% rdg ±0.001 % f.s. 1000 mΩ range: ±0.012% rdg ±0.001 % f.s. 1000 Ω range: ±0.006% rdg ±0.001 % f.s.
Testing current (Measurement current)High mode: 1000μΩ (1 A) to 1000 MΩ (up to 1 μA) Low mode: 100 mΩ (100 mA) to 100 Ω (1 mA) Low power mode (LP): Low power measurement with measurement current and open circuit voltage down to 20 mV LP1000 mΩ (1 mA) to LP1000 Ω (5 μA)
Measurement speedRepresentative value: FAST (2.3 ms) / MED (50 Hz: 22 ms, 60 Hz: 19 ms) / SLOW1 (102 ms) / SLOW2 (202 ms) PR10 mΩ range*: FAST (21 ms) / MED (50 Hz: 41 ms, 60 Hz: 37 ms) / SLOW1 (121 ms) / SLOW2 (221 ms)
Path resistance tolerance(reference values) Path resistance between SOURCE B and SOURCE A (other than measurement target) Range: 100 mΩ or less (PR* mode off) : 2.6 Ω Range: 100 mΩ or less (PR* mode on) : 3.5 Ω Range: 1000 mΩ: 15 Ω Range: 10 Ω : 150 Ω Range: 100 Ω : 100 Ω Range: 10 kΩ : 500 Ω Range: 100 kΩ or greater: 1 kΩ
Maximum open-terminal voltageRange: 1000 Ω or less: 8.0 V Range: 10 kΩ or greater: 20 V
Temperature measurementTemperature Sensor (Z2001[included accessories]): -10.0℃ to 99.9℃ Analog input (Ex: Infrared thermometer): DC 0 V to 2.0 V
Multiplexer (built-in option)* *RM3545A-2 onlyMultiplexer unit Z3003 Number of installable units:Max. 2 Maximum number of channels : 20 channels (4-wire method), 42 channels (2-wire method) Switching time : 30 ms
Multiplexer (external option)Switch Mainframe Maximum number of channels (SW1001): 33 channels (4-wire method) Maximum number of channels (SW1002): 132 channels (4-wire method) Switching time:11 ms
Communication interfacesLAN (TCP/IP, 10BASE-T/100BASE-TX), RS-232C (Max. 115200 bps, also used as printer interface), USB, EXT I/O (D-sub 37-pin, Analog output (D/A output voltage range: DC 0 V to 1.5 V )
FunctionsContact check, Zero adjustment (within each range ±50% f.s.), Zero-adjustment-free accuracy guaranteed, OVC function, Contact improvement function (max. applied voltage: 5V; max. applied current: 10 mA), Low-power mode (maximum open voltage: 20 mV), Auto-hold function, Comparator, Temperature measurement function, Temperature correction (TC) function, Temperature conversion (ΔT) function, Statistical calculation function, Delay function, Averaging function, Saving panels (saving of measurement c
Power supply100 V to 240 V AC, 50 Hz/60 Hz, Rated power consumption: 40 VA max.
Normal power consumption (Reference value)16 W (Testting current 1 A, LCD on)
Dimensions and massRM3545A-1: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D, 2.7 kg (95.2 oz) RM3545A-2: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D, 3.4 kg (119.9 oz)
Supplied with
ContentsPower cord ×1, Temperature sensor Z2001 ×1, Male EXT I/O connector ×1, EXT. I/O connector cover ×1, Spare fuse (F1.6AH 250 V)×1, Start up guide ×1, Operating Precautions ×1, Instruction manual ×1
Ordering
Order codeRM3545A-1 (Single-channel model)
NoteMeasurement probe is not included with the unit, purchase separately if required.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.