Hioki RM3542-50 Resistance Meter

Brand
Hioki
Model number
RM3542-50

Resistance meter for fast testing of small components: 100 mΩ to 100 MΩ ranges, 0.9 ms FAST mode, applied voltage limit and contact improvement functions; fixtures sold separately.

Price and availability on request

Request a quote

Sent with the product details: Hioki RM3542-50 Resistance Meter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Applied voltage limit function lets you switch the detection voltage to 5 V or less
  • Contact improvement function suppresses rush current to aid in probing of super-small components
  • Extensive selection of measurement ranges ensures the right detection voltage and delivers stable measurement
  • Scaling function corrects for mounting state and test stage differences

Specifications

Specifications
Resistance range[at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ resolution) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 16 steps [at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 6 steps
DisplayMonochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy[with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. (best case)
Testing current[at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC
Open-terminal voltage20 V DC max. (with applied voltage limit function enabled: max. 10 V DC)
Sampling rateFAST, MEDIUM, SLOW, 3 settings
Measurement times[at 100 Ω /1000 Ω ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time)
Integration time0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period)
Other functionsComparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), Applied Voltage Limit Function, Scaling Function, OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger fun
InterfacesRS-232C, Printer, GP-IB (Model RM3542-51)
External I/OTrigger, Hold input, Comparator output, Settings monitor terminal
Power supply100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions and mass260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz)
Supplied with
ContentsPower cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1
Ordering
Order codeRM3542-50
NoteTest fixtures are not supplied with the unit. Please select an optional test fixture when ordering.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.