Hioki RM3542C-2 Resistance Meter Standard Model with GP-IB

Brand
Hioki
Model number
RM3542C-2

DC resistance meter for in-line testing of chip resistors and ferrite beads: 100 mΩ to 100 MΩ ranges, 0.9 ms FAST mode and jumper resistor support; probes and fixtures sold separately. Standard model with GP-IB.

Price and availability on request

Request a quote

Sent with the product details: Hioki RM3542C-2 Resistance Meter Standard Model with GP-IB.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Jumper Resistance Measurement Support
  • Takt time× repeatability
  • Low-stress testing
  • Noise immunity

Specifications

Specifications
Resistance range[at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ* resolution) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 16 steps *Additional range for RM3542C-3: 10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) [at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 6 steps
DisplayMonochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy[with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. 90-day accuracy (RM3542C-3 only) [with SLOW mode, at 100 mΩ range] ±0.012 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 Ω range] ±0.005 % rdg. ±0.001 % f.s.
Testing current[at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC
Open-terminal voltage20 V DC max. (with applied voltage limit function enabled: max. 5 V DC)
Sampling rateFAST, MEDIUM, SLOW, 3 settings
Measurement times[at 100 Ω /300 Ω/1000 Ω ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time)
Integration time0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period)
Other functionsComparator (set-value vs. measured-value comparison), BIN Measurement (RM3542C-3), Low-power Resistance Measurement, Delay Setting, Offset Voltage Compensation (OVC), Integration Time Setting, Average (RM3542C-3), Faulty Measurement Detection, Probe Short-Circuit Detection, Contact Improvement, Current Mode Setting, Stage Mismatch Prevention, Scaling, Retry, Applied Voltage Limiter Function, Jumper Resistance Measurement Support, Preset, ΔR (RM3542C-3), Memory, Statistical Calculation, Settings
InterfacesRS-232C, Printer (RM-232C), GP-IB (Model RM3542C-2)
External I/OTrigger, Hold input, Comparator output and other, Settings monitor terminal
Power supply100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions and mass260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz)
Supplied with
ContentsPower cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1
Ordering
Order codeRM3542C-2 (Standard model (GP-IB compatible))
NoteProbes and test fixtures are not included with the main unit. Please purchase them separately as needed