Hioki IM7581-02 Impedance Analyzer with 2 m Cable

Brand
Hioki
Model number
IM7581-02

RF impedance analyzer, 100 kHz to 300 MHz, using the RF I-V method with ±0.72% rdg. basic accuracy and 0.5 ms fastest test speed. Supplied with a 2 m connection cable.

Price and availability on request

Request a quote

Sent with the product details: Hioki IM7581-02 Impedance Analyzer with 2 m Cable.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 100 kHz to 300 MHz testing source frequency
  • Fastest test speed of 0.5 msec (Analog measurement time)
  • ±0.72% rdg. basic accuracy
  • RF I-V method
  • Half-rack size body and palm-sized test head
  • Comprehensive contact check (via DCR testing, Hi-Z reject or waveform judgment)
  • Make frequency sweeps, level sweeps and time interval measurements in Analyzer Mode

Specifications

Specifications
Measurement modesLCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
Measurement parametersZ, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
Measurable range100 mΩ to 5 kΩ
Display rangeZ: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ) Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99) θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF) D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS) G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %)
Basic accuracyZ: ±0.72 % rdg. θ: ±0.41°
Measurement frequency100.00 kHz to 300.00 MHz (5 digits resolution)
Measurement signal levelPower: -40.0 dBm to +7.0 dBm Voltage: 4 mV to 1001 mVrms Current: 0.09 mA to 20.02 mArms User-configured power, voltage, and current
Output impedance50 Ω
Display8.4-inch color TFT with touch screen
Measurement speedsFAST: 0.5 ms / MED: 0.9 ms / SLOW: 2.1 ms / SLOW2: 3.7 ms Analog measurement time
FunctionsContact check, Comparator, BIN measurement (classification), Panel loading/saving, Memory function, Equivalent circuit analysis, Correlation compensation
InterfacesHandler, USB, LAN, GP-IB (optional), RS-232C (optional)
Power supply100 to 240 V AC, 50/60 Hz, 70 VA max.
Dimensions and massMain unit: 215 mm (8.46 in) W × 200 mm (7.87 in) H × 268 mm (10.55 in) D, 6.5 kg (229.3 oz) Test head: 61 mm (2.40 in) W × 55 mm (2.17 in) H × 24 mm (0.94 in) D, 175 g (6.2 oz)
Supplied with
ContentsTest head ×1, Connection cable ×1, Power cord ×1, Instruction manual ×1
Ordering
Order codeIM7581-02 (Connection cable 2 m is bundled)
NoteThe instrument does not ship with a test fixture or probe. A test fixture designed specifically for use with the Impedance Analyzer is required.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.