Hioki IM3536 LCR Meter

Brand
Hioki
Model number
IM3536

LCR meter covering DC and 4 Hz to 8 MHz with ±0.05% rdg. representative accuracy, 1 ms fastest measurement and guaranteed accuracy from 1 mΩ.

Price and availability on request

Request a quote

Sent with the product details: Hioki IM3536 LCR Meter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • DC, 4 Hz to 8 MHz measurement frequency
  • High-speed measurement of 1 ms (fastest time)
  • High-precision measurement of ±0.05% rdg. (representative value)
  • Guaranteed accuracy range from 1 mΩ, low-impedance measurement with unmatched repeatability
  • DC bias function: Measure under conditions simulating actual use or in accordance with industry standards
  • Exceptional specifications and cost-performance for a wide range of applications, from R&D to production lines

Specifications

Specifications
Measurement modesLCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions)
Measurement parametersZ, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε
Measurement range100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Display rangeZ: 0.00 m to 9.99999 GΩ, Y: 0.000 n to 9.99999 GS, θ: ± (0.000° to 180.000°), Q: ± (0.00 to 9999.99), Rdc: ± (0.00 m to 9.99999 GΩ), D: ± (0.00000 to 9.99999), Δ%: ± (0.000 % to 999.999 %), or other
Basic accuracyZ ±0.05% rdg. θ: ±0.03° (representative value, Measurable range: 1 mΩ to 200 MΩ)
Measurement frequency4 Hz to 8 MHz (5 digits setting resolution, minimum resolution 10 mHz)
Measurement signal level[Normal mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 5 V rms (maximum 50 mA rms) 1.0001 MHz to 8 MHz: 10 mV to 1 V rms (maximum 10mA rms) [Low impedance high repeatability mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 1 V rms (maximum 100 mA rms) [Normal mode: CC mode] 4 Hz to 1.0000 MHz: 10 μA to 50 mA rms (maximum 5 V rms) 1.0001 MHz to 8 MHz: 10 μA to 10 mA rms (maximum 1 V rms) [Low impedance high repeatability mode: CC mode] 4 Hz to 1.0000 MHz: 10 μA to 100 mA rms (maximum 1 V rm
DC bias measurementGenerating range: DC voltage 0 V to 2.50 V (10 mV resolution) In low Z high repeatability mode: 0 V to 1 V (10 mV resolution)
Output impedanceNormal mode: 100 Ω, Low impedance high repeatability mode: 10 Ω
Display5.7-inch color TFT with touch panel
FunctionsComparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function
InterfacesEXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD
Power supply100 to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and mass330 mm (12.99 in.) W × 119 mm (4.69 in.) H × 230 mm (9.06 in.) D, 4.2 kg (148.1 oz.)
Supplied with
ContentsPower cord ×1, Instruction manual ×1
Ordering
Order codeIM3536 (LCR Meter, measurement frequency: DC, or 4 Hz to 8 MHz)
NoteThis product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.