Fluke 1664 FC Multifunction Installation Tester

Brand
Fluke
Model number
1664 FC

Multifunction installation tester with Auto Test, insulation pre-test, EV charger RCD tests and Fluke Connect sharing.

Price and availability on request

Request a quote

Sent with the product details: Fluke 1664 FC Multifunction Installation Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Includes "Insulation Pre-test" that detects when appliances are connected to the system and stops the test
  • Runs seven installation tests automatically in one sequence with a single connection through Auto Test
  • Allows you to share test results in real time over your smartphone via Fluke Connect Measurements
  • 6 mA RDC-DD testing for EV charging stations

Specifications

AC voltage measurement
Range500 V
Resolution0.1 V
Accuracy 45 Hz – 66 Hz0.8% + 3
Input impedance360 kΩ
Overload protection660 V rms
Continuity testing (RLO)
Range (autoranging)20 Ω; 200 Ω; 2000 Ω
Resolution0.01 Ω; 0.1 Ω; 1 Ω
Open Circuit Voltage>4 V
Insulation resistance measurement (RISO)
Test voltages50-100-250-500-1000 V
Accuracy of test voltage (at rated test current)+10%, -0%
Test voltage50 V; 100 V; 250 V; 500 V; 1000 V
Insulation resistance range20 MΩ; 50 MΩ; 20 MΩ; 100 MΩ; 20 MΩ; 200 MΩ; 20 MΩ; 200 MΩ; 500 MΩ; 20 MΩ; 200 MΩ; 1000 MΩ
Resolution0.01 MΩ; 0.1 MΩ; 0.01 MΩ; 0.1 MΩ; 0.01 MΩ; 0.1 MΩ; 0.01 MΩ; 0.1 MΩ; 1 MΩ; 0.01 MΩ; 0.1 MΩ; 1 MΩ
Test current1 mA @ 50 kΩ; 1 mA @ 100 kΩ; 1 mA @ 250 kΩ; 1 mA @ 500 kΩ; 1 mA @ 1 MΩ
Loop and line impedance (ZI)
Range10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω
Resolution0.001 Ω/ 0.01 Ω/ 0.1 Ω/1 Ω
Prospective earth fault current, PSC test
Range1000 A; 10 kA (50 kA)
Resolution1 A; 0.1 kA
ComputationProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD testing, RCD types tested
RCD TypeAC¹; G²,S³
Model 1663A4, AC¹, G²,S³
Model 1664 FCA, AC, B5, S
Notes¹Responds to AC; ²General, no delay; ³Time delay; ⁴Responds to pulsed signal; ⁵Responds to smooth DC signal
Tripping speed test (ΔT)
Current settings¹10-30-100-300-500-1000 mA – VAR; 10-30-100 mA
Multiplierx ½, x 1; x 5; VAR Mode Type B - 6, 60, 200 mA
Measurement range, RCD Type G310 ms; 50 ms
Measurement range, RCD Type S510 ms; 160 ms
Measurement range, EV, RDC-DD6 mA - 10s; 60 mA - 0.3s; 200 mA - 0.1s
Notes¹1000 mA type AC only; 700 mA maximum type A in VAR mode; The VAR Mode at RCD type B (smooth DC currents) generates the test currents acc. to IEC 62955 for RCD type A-EV or RDC-DD (6/60/200 mA and ramp <2 to 6 mA).
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current range30% to 110% of RCD rated current¹; <2 mA to 6 mA smooth DC³
Step size10% of IΔN²; Linear rising within 30 s
Dwell time, RCD Type G300 ms/step
Dwell time, RCD Type S500 ms/step
Measurement accuracy±5%
Specified trip current ranges (EN 61008-1)50% to 100% for Type AC; 35% to 140% for Type A (>10 mA); 35% to 200% for Type A (≤10 mA); 50% to 200% for Type B
Notes¹30% to 150% for Type A IΔN > 10 mA; 30% to 210% for Type A IΔN = 10 mA; 20% to 210% for Type B; ²5% for Type B; ³For RCD type A-EV/RDC-DD acc. to IEC 62955
Earth Resistance Test (RE)
Range200 Ω; 2000 Ω
Resolution0.1 Ω; 1Ω
Frequency128 Hz
Output Voltage25 V
Phase Sequence Indication
IconPhase Sequence indicator is active.
General Specifications
Size (L x W x H)10 x 25 x 12.5 cm
Weight (incl. batteries)1.3 Kg
Battery size, quantityType AA, 6 ea.
SealingIP-40
SafetyComplies with EN/IEC 61010-1 and EN/IEC 61010-2-034
OvervoltageCAT III; 500V; CAT IV 300V
PerformanceEN61557-1 to EN61557-7 and EN61557-10
Supplied with
Contents6x AA (IEC LR6) cell batteries; C1600 hard carrying case; Zero adapter; Heavy duty mains cord; STD standard test lead set; Padded carrying and waist strap; Quick reference guide; TP165X remote control probe and lead

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 1664 FC

The Fluke 1664 FC runs seven installation tests automatically with one connection (Auto Test), and its insulation pre-test stops the test if appliances are connected. It can test EV charging station protection devices and shares results in real time through the Fluke Connect app.