Fluke 1587 FC Insulation Multimeter with Fluke Connect
- Brand
- Fluke
- Model number
- 1587 FC
- Category
- Insulation Multimeters
Insulation multimeter with Fluke Connect: watch and share insulation results on your phone from a safe distance.
Price and availability on request
Key features
- Safety first. Connect the insulation tester then keep yourself out of harm's way by monitoring your test measurements remotely
- Prove your job is done right by quickly seeing and sharing insulation resistance test results wirelessly with your smartphone
- Quickly find problems by saving and comparing measurements over time on a wireless device
Specifications
| 600.0 mV, Resolution | 0.1 mV |
|---|---|
| 600.0 mV, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) |
| 600.0 mV | Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts); ±(2% + 3) |
| 6.000 V, Resolution | 0.001 V |
| 6.000 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) |
| 6.000 V | Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts); ±(2% + 3) |
| 60.00 V, Resolution | 0.01 V |
| 60.00 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) |
| 60.00 V | Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts); ±(2% + 3) |
| 600.0 V, Resolution | 0.1 V |
| 600.0 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) |
| 600.0 V | Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts); ±(2% + 3)¹ |
| 1000 V, Resolution | 1 V |
| 1000 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(2% + 3) |
| 1000 V | Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts); ±(2% + 3)¹ |
| 600.0 mV, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 6.000 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 60.00 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 600.0 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 1000 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 6.000 V dc | Resolution 0.001 V; Accuracy ±(% of Rdg + Counts) ±(0.09% + 2) |
|---|---|
| 60.00 V dc | Resolution 0.01 V; Accuracy ±(% of Rdg + Counts) ±(0.09% + 2) |
| 600.0 V dc | Resolution 0.1 V; Accuracy ±(% of Rdg + Counts) ±(0.09% + 2) |
| 1000 V dc | Resolution 1 V; Accuracy ±(% of Rdg + Counts) ±(0.09% + 2) |
| Input impedance | 10 MΩ (nominal), <100 pF |
| Normal mode rejection ratio | >60 dB @ 50 Hz or 60 Hz |
| Common mode rejection ratio | >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) |
| 600.0 mVdc | Resolution 0.1 mV; Accuracy ±(% of Rdg + Counts) ±(0.1% + 1) |
|---|
| Range | 400 mA; 60 mA |
|---|---|
| Resolution | 0.1 mA; 0.01 mA |
| Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)¹ |
| Burden voltage (Typical) | 2 mV/mA |
| Range | 400 mA; 60 mA |
|---|---|
| Resolution | 0.1 mA; 0.01 mA |
| Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
| Burden voltage (Typical) | 2 mV/mA |
| Overload | 600 mA for 2 minutes maximum |
| Fuse protection for mA input | 0.44 mA, 1000 V, IR 10 kA |
| AC conversion | Inputs are ac-coupled and calibrated to the rms value of sine wave input |
| 600.0 Ω | Resolution 0.1 Ω; Accuracy +(% of Rdg+Counts)¹ ±(0.9% + 2) |
|---|---|
| 6.000 kΩ | Resolution 0.001 kΩ; Accuracy +(% of Rdg+Counts)¹ ±(0.9% + 2) |
| 60.00 kΩ | Resolution 0.01 kΩ; Accuracy +(% of Rdg+Counts)¹ ±(0.9% + 2) |
| 600.0 kΩ | Resolution 0.1 KΩ; Accuracy +(% of Rdg+Counts)¹ ±(0.9% + 2) |
| 6.000 MΩ | Resolution 0.001 MΩ; Accuracy +(% of Rdg+Counts)¹ ±(0.9% + 2) |
| 50.0 MΩ ² | Resolution 0.01 MΩ; Accuracy +(% of Rdg+Counts)¹ ±(1.5% + 3) |
| Overload protection | 1000 V rms or dc |
| Open circuit test voltage | <8.0 V dc |
| Short circuit current | <1.1 mA |
| Diode test indication | Display voltage drop: 0.6 V at1.0 mA nominal test current: |
|---|---|
| Accuracy | ±(2% + 3) |
| Continuity indication | Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω |
|---|---|
| Open circuit voltage | <8.0 V |
| Short circuit current | 1.0 mA typical |
| Overload protection | 1000 V rms |
| Response time | >1 m sec |
| 99.99 Hz | Resolution 0.01 Hz; Accuracy ±(% of Rdg+Counts) ±(0.1% + 1) |
|---|---|
| 999.9 Hz | Resolution 0.1 Hz; Accuracy ±(% of Rdg+Counts) ±(0.1% + 1) |
| 9.999 kHz | Resolution 0.001 kHz; Accuracy ±(% of Rdg+Counts) ±(0.1% + 1) |
| 99.99 kHz | Resolution 0.01 kHz; Accuracy ±(% of Rdg+Counts) ±(0.1% + 1) |
| 600.0 mV ac | V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 100.0 mV; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz; 150.0 mV |
|---|---|
| 6.0 V | V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 1.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz; 1.5 V |
| 6.0 V, DC Trigger Levels¹ to 20 kHz² | -400.0 mV and 2.5 V |
| 60.0 V | V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 10.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz; 36.0 V |
| 60.0 V, DC Trigger Levels¹ to 20 kHz² | 1.2 V and 4.0 V |
| 600.0 V | V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 100.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz |
| 600.0 V, DC Trigger Levels¹ to 20 kHz² | 12.0 V and 40.0 V |
| 1000.0 V | V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 300.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz |
| 1000.0 V, DC Trigger Levels¹ to 20 kHz² | 12.0 V and 40.0 V |
| 1000 nF | Resolution 1 nF; Accuracy ±(% of Rdg+Counts) ±(1.2% + 2) |
|---|---|
| 10.00 μF | Resolution 0.01 μF; Accuracy ±(% of Rdg+Counts) ±(1.2% + 2) |
| 100.0 μF | Resolution 0.1 μF; Accuracy ±(% of Rdg+Counts) ±(1.2% ±90 counts) |
| 9999 μF | Resolution 1 μF; Accuracy ±(% of Rdg+Counts) ±(1.2% ±90 counts) |
| -40 ° C to 537 ° C | Resolution 0.1 °C; Accuracy ±(% of Rdg+Counts)¹ ±(1% + 10 counts) |
|---|---|
| -40 ° F to 998 ° F | Resolution 0.1 °F; Accuracy ±(% of Rdg+Counts)¹ ±(1% + 18 counts) |
| Measurement range | 0.01 MΩ to 2 GΩ |
|---|---|
| Test voltages | 50, 100, 250, 500, 1000 V |
| Test voltage accuracy | +20%, -0% |
| Short-circuit test current | 1 mA nominal |
| Auto discharge | Discharge time <0.5 second for C = 1 μF or less |
| Live circuit detection | Inhibit test if terminal voltage > 30 V prior to initialization of test |
| Maximum capacitive load | Operable with up to 1 μF load |
| 50 V (0% to +20%), Display range | 0.01 to 6.00 MΩ; 6.0 to 50.0 MΩ |
|---|---|
| 50 V (0% to +20%), Resolution | 0.01 MΩ; 0.1 MΩ |
| 50 V (0% to +20%), Test current | 1 mA @ 50 kΩ |
| 50 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) |
| 100 V (0% to +20%), Display range | 0.01 to 6.00 MΩ; 6.0 to 60.0 MΩ; 60 to 100 MΩ |
| 100 V (0% to +20%), Resolution | 0.01 MΩ; 0.1 MΩ |
| 100 V (0% to +20%), Test current | 1 mA @ 100 kΩ |
| 100 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) |
| 250 V (0% to +20%), Display range | 0.1 to 60.0 MΩ; 60 to 250 MΩ |
| 250 V (0% to +20%), Resolution | 0.1 MΩ |
| 250 V (0% to +20%), Test current | 1 mA @ 250 kΩ |
| 250 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) |
| 500 V (0% to +20%), Display range | 0.1 to 60.0 MΩ; 60 to 500 MΩ |
| 500 V (0% to +20%), Resolution | 0.1 MΩ |
| 500 V (0% to +20%), Test current | 1 mA @ 500 kΩ |
| 500 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) |
| 1000 V (0% to +20%), Display range | 0.1 to 60.0 MΩ; 60 to 600 MΩ; 0.6 to 2.0 GΩ |
| 1000 V (0% to +20%), Resolution | 0.1 MΩ; 100 MΩ |
| 1000 V (0% to +20%), Test current | 1 mA @ 1 MΩ |
| 1000 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts); ±(10% + 3 counts) |
| Maximum voltage applied to any terminal and common | 1000 V |
|---|---|
| Storage temperature | -40 °C to 60 °C (-40 °F to 140 °F) |
| Operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) |
| Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) |
| Relative humidity | Noncondensing; 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F); 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F); 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F) |
| Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
| IEC 61010-1 | Pollution Degree 2 |
|---|---|
| IEC 61010-2-033 | CAT IV 600 V; CAT III 1000 V |
| Batteries | Four AA batteries (IEC LR6) |
| Battery life | Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| Size (H x W x L) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) |
| Weight | 550 g (1.2 lb) |
| Altitude, Operating | 2000 m |
| Altitude, Storage | 12,000 m |
| Over-range capability | 110% of range except for capacitance which is 100% |
| Frequency overload protection | <107 V Hz |
| Fuse protection for mA input | 0.44A, 1000 V, IR 10 kA |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 1587 FC
The Fluke 1587 FC combines an insulation tester and a true-rms multimeter, and works with the Fluke Connect app so you can monitor insulation tests from a distance and share results. A K-type thermocouple is supplied for temperature measurement.