Fluke 1587 FC Insulation Multimeter with Fluke Connect

Brand
Fluke
Model number
1587 FC

Insulation multimeter with Fluke Connect: watch and share insulation results on your phone from a safe distance.

Price and availability on request

Request a quote

Sent with the product details: Fluke 1587 FC Insulation Multimeter with Fluke Connect.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Safety first. Connect the insulation tester then keep yourself out of harm's way by monitoring your test measurements remotely
  • Prove your job is done right by quickly seeing and sharing insulation resistance test results wirelessly with your smartphone
  • Quickly find problems by saving and comparing measurements over time on a wireless device

Specifications

Range
600.0 mV, Resolution0.1 mV
600.0 mV, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±⁠(1% + 3)
600.0 mVAccuracy 60 Hz to 5000 Hz ±⁠(% of Rdg + Counts); ±⁠(2% + 3)
6.000 V, Resolution0.001 V
6.000 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±⁠(1% + 3)
6.000 VAccuracy 60 Hz to 5000 Hz ±⁠(% of Rdg + Counts); ±⁠(2% + 3)
60.00 V, Resolution0.01 V
60.00 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±⁠(1% + 3)
60.00 VAccuracy 60 Hz to 5000 Hz ±⁠(% of Rdg + Counts); ±⁠(2% + 3)
600.0 V, Resolution0.1 V
600.0 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±⁠(1% + 3)
600.0 VAccuracy 60 Hz to 5000 Hz ±⁠(% of Rdg + Counts); ±⁠(2% + 3)¹
1000 V, Resolution1 V
1000 V, Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±⁠(2% + 3)
1000 VAccuracy 60 Hz to 5000 Hz ±⁠(% of Rdg + Counts); ±⁠(2% + 3)¹
600.0 mV, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
6.000 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
60.00 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
600.0 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
1000 V, Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
DC Voltage Measurement
6.000 V dcResolution 0.001 V; Accuracy ±⁠(% of Rdg + Counts) ±⁠(0.09% + 2)
60.00 V dcResolution 0.01 V; Accuracy ±⁠(% of Rdg + Counts) ±⁠(0.09% + 2)
600.0 V dcResolution 0.1 V; Accuracy ±⁠(% of Rdg + Counts) ±⁠(0.09% + 2)
1000 V dcResolution 1 V; Accuracy ±⁠(% of Rdg + Counts) ±⁠(0.09% + 2)
Input impedance10 MΩ (nominal), <100 pF
Normal mode rejection ratio>60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
DC Millivolts Measurement
600.0 mVdcResolution 0.1 mV; Accuracy ±⁠(% of Rdg + Counts) ±⁠(0.1% + 1)
AC 45 Hz to 1000 Hz
Range400 mA; 60 mA
Resolution0.1 mA; 0.01 mA
Accuracy ±(% of Rdg+Counts)±⁠(1.5% + 2)¹
Burden voltage (Typical)2 mV/mA
DC
Range400 mA; 60 mA
Resolution0.1 mA; 0.01 mA
Accuracy ±(% of Rdg+Counts)±⁠(0.2% + 2)
Burden voltage (Typical)2 mV/mA
Overload600 mA for 2 minutes maximum
Fuse protection for mA input0.44 mA, 1000 V, IR 10 kA
AC conversionInputs are ac-coupled and calibrated to the rms value of sine wave input
Ohms Measurement
600.0 ΩResolution 0.1 Ω; Accuracy +(% of Rdg+Counts)¹ ±⁠(0.9% + 2)
6.000 kΩResolution 0.001 kΩ; Accuracy +(% of Rdg+Counts)¹ ±⁠(0.9% + 2)
60.00 kΩResolution 0.01 kΩ; Accuracy +(% of Rdg+Counts)¹ ±⁠(0.9% + 2)
600.0 kΩResolution 0.1 KΩ; Accuracy +(% of Rdg+Counts)¹ ±⁠(0.9% + 2)
6.000 MΩResolution 0.001 MΩ; Accuracy +(% of Rdg+Counts)¹ ±⁠(0.9% + 2)
50.0 MΩ ²Resolution 0.01 MΩ; Accuracy +(% of Rdg+Counts)¹ ±⁠(1.5% + 3)
Overload protection1000 V rms or dc
Open circuit test voltage<8.0 V dc
Short circuit current<1.1 mA
Diode Test
Diode test indicationDisplay voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy±⁠(2% + 3)
Continuity Test
Continuity indicationContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage<8.0 V
Short circuit current1.0 mA typical
Overload protection1000 V rms
Response time>1 m sec
Frequency Measurement
99.99 HzResolution 0.01 Hz; Accuracy ±⁠(% of Rdg+Counts) ±⁠(0.1% + 1)
999.9 HzResolution 0.1 Hz; Accuracy ±⁠(% of Rdg+Counts) ±⁠(0.1% + 1)
9.999 kHzResolution 0.001 kHz; Accuracy ±⁠(% of Rdg+Counts) ±⁠(0.1% + 1)
99.99 kHzResolution 0.01 kHz; Accuracy ±⁠(% of Rdg+Counts) ±⁠(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV acV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 100.0 mV; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz; 150.0 mV
6.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 1.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz; 1.5 V
6.0 V, DC Trigger Levels¹ to 20 kHz²-400.0 mV and 2.5 V
60.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 10.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz; 36.0 V
60.0 V, DC Trigger Levels¹ to 20 kHz²1.2 V and 4.0 V
600.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 100.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz
600.0 V, DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V
1000.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz; 300.0 V; V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz
1000.0 V, DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V
Capacitance
1000 nFResolution 1 nF; Accuracy ±⁠(% of Rdg+Counts) ±⁠(1.2% + 2)
10.00 μFResolution 0.01 μF; Accuracy ±⁠(% of Rdg+Counts) ±⁠(1.2% + 2)
100.0 μFResolution 0.1 μF; Accuracy ±⁠(% of Rdg+Counts) ±⁠(1.2% ±90 counts)
9999 μFResolution 1 μF; Accuracy ±⁠(% of Rdg+Counts) ±⁠(1.2% ±90 counts)
Temperature Measurement
-40 ° C to 537 ° CResolution 0.1 °C; Accuracy ±⁠(% of Rdg+Counts)¹ ±⁠(1% + 10 counts)
-40 ° F to 998 ° FResolution 0.1 °F; Accuracy ±⁠(% of Rdg+Counts)¹ ±⁠(1% + 18 counts)
Insulation Specifications
Measurement range0.01 MΩ to 2 GΩ
Test voltages50, 100, 250, 500, 1000 V
Test voltage accuracy+20%, -0%
Short-circuit test current1 mA nominal
Auto dischargeDischarge time <0.5 second for C = 1 μF or less
Live circuit detectionInhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive loadOperable with up to 1 μF load
Output Voltage
50 V (0% to +20%), Display range0.01 to 6.00 MΩ; 6.0 to 50.0 MΩ
50 V (0% to +20%), Resolution0.01 MΩ; 0.1 MΩ
50 V (0% to +20%), Test current1 mA @ 50 kΩ
50 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts)±⁠(3% + 5 counts)
100 V (0% to +20%), Display range0.01 to 6.00 MΩ; 6.0 to 60.0 MΩ; 60 to 100 MΩ
100 V (0% to +20%), Resolution0.01 MΩ; 0.1 MΩ
100 V (0% to +20%), Test current1 mA @ 100 kΩ
100 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts)±⁠(3% + 5 counts)
250 V (0% to +20%), Display range0.1 to 60.0 MΩ; 60 to 250 MΩ
250 V (0% to +20%), Resolution0.1 MΩ
250 V (0% to +20%), Test current1 mA @ 250 kΩ
250 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts)±⁠(1.5% + 5 counts)
500 V (0% to +20%), Display range0.1 to 60.0 MΩ; 60 to 500 MΩ
500 V (0% to +20%), Resolution0.1 MΩ
500 V (0% to +20%), Test current1 mA @ 500 kΩ
500 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts)±⁠(1.5% + 5 counts)
1000 V (0% to +20%), Display range0.1 to 60.0 MΩ; 60 to 600 MΩ; 0.6 to 2.0 GΩ
1000 V (0% to +20%), Resolution0.1 MΩ; 100 MΩ
1000 V (0% to +20%), Test current1 mA @ 1 MΩ
1000 V (0% to +20%), Resistance accuracy ±(% of Rdg + Counts)±⁠(1.5% + 5 counts); ±⁠(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common1000 V
Storage temperature-40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidityNoncondensing; 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F); 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F); 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Safety
IEC 61010-1Pollution Degree 2
IEC 61010-2-033CAT IV 600 V; CAT III 1000 V
BatteriesFour AA batteries (IEC LR6)
Battery lifeMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight550 g (1.2 lb)
Altitude, Operating2000 m
Altitude, Storage12,000 m
Over-range capability110% of range except for capacitance which is 100%
Frequency overload protection<107 V Hz
Fuse protection for mA input0.44A, 1000 V, IR 10 kA

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 1587 FC

The Fluke 1587 FC combines an insulation tester and a true-rms multimeter, and works with the Fluke Connect app so you can monitor insulation tests from a distance and share results. A K-type thermocouple is supplied for temperature measurement.