Delta VFD2500CP43A-00 CP2000 Fan and Pump AC Drive, 250 kW / 340 HP, 3-Phase 460 V, IP00 / IP20 Open Type

Brand
Delta
Model number
VFD2500CP43A-00

CP2000 drive for fans and pumps, 250 kW (340 HP) on 3-phase 460 V, 481 A light duty and 395 A normal duty, with multi-pump control, fire mode, built-in 10k-step PLC, Modbus and BACnet; frame G1.

Price and availability on request

Request a quote

Sent with the product details: Delta VFD2500CP43A-00 CP2000 Fan and Pump AC Drive, 250 kW / 340 HP, 3-Phase 460 V, IP00 / IP20 Open Type.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • With a built-in 10K steps Delta PLC allows user to execute distributional control and independent control when connecting to a network system. Delta CP2000 series drives provide you the intelligent control possibility beyond your imagination.
  • The calendar function allows user to program the PLC procedure, the ON/OFF in chronological order, the daylight saving time and etc.
  • A wide range of models to fulfill the demands of different industries.
  • The modularized design eases the maintenance and expansion.
  • High-speed communication interfaces with Modbus protocol and BACnet protocol built in. Diverse communication options are available for you: the BACnet IP, PROFINET, ProfiBUS-DP, the DeviceNet, the Modbus TCP, the Ethernet-IP and the CANopen Cards.
  • Special PCB coating design (Printed Circuit Board) for enhancing environmental tolerance.
  • Complied with global safety standards: CE, UL and cUL
  • Run fire mode while emergency to have uninterrupted smoke releasing and pressure adding
  • Multi pumps control at fixed amount, fixed time circulating control. Able to control 8 pumps at the same time. (Optional multi-control relay card is required.)

Specifications

Product
SeriesCP2000
Rating
Light duty motor output250 kW (340 HP)
Light duty rated output current481 A
Light duty rated output capacity383 kVA
Normal duty motor output200 kW (270 HP)
Normal duty rated output current395 A
Normal duty rated output capacity315 kVA
Overload toleranceLight duty: 120% of rated current for 1 minute during every 5 minutes; normal duty: 120% for 1 minute during every 5 minutes and 160% for 3 seconds during every 25 seconds
Input
Input current (light / normal duty)481 A / 390 A
Power supply capacity (light / normal duty)399.9 kVA / 324.2 kVA
Rated voltage / frequency3 phase, 380 ~ 480 VAC (-15% ~ +10%), 50/60 Hz
Operating voltage range323 ~ 528 VAC
Frequency tolerance47 ~ 63 Hz
Power factor> 0.98
Output
Carrier frequency2 ~ 9 kHz (default 4)
Max. output frequency599.00 Hz
Design
FrameG1
Efficiency98.2%
Weight134 ±4 kg
Cooling methodFan cooling
Braking chopperOptional
DC chokeBuilt-in reactor, comply with IEC61000-3-12
EMC filterOptional
Protection levelIP20 / UL Open Type (IP00 for the terminal area), no conduit box
Environment
Operation temperature-10 ~ 50 °C
Control
Control methodV/F, SVC, PM Sensorless, SynRM Sensorless
Starting torqueUp to 150% or above at 0.5 Hz
V/F curve4 point adjustable V/F curve and square curve
Frequency setting signal0–+10 V, 4–20 mA, 0–20 mA
Accel./decel. time0.00–600.00 / 0.0–6000.0 seconds
CommunicationModbus communication (RS-485 RJ45) built in
STOSafe Torque Off (STO per EN 61800-5-2); EN IEC 62061 maximum SIL 2; EN 61508 SIL 2; EN ISO 13849-1, Cat.3/PL d
Restart after instantaneous power failureParameter setting up to 20 seconds
Ordering
Delta India price listDC Choke, Inbuilt PLC, LCD Display unit (Delta price list 2026-27, July edition)
Applications
Typical applicationsFixed-displacement pumps (fix flow and fix time), building automation, factory automation, HVAC drives, cooling pumps, cooling towers and general motor applications.