Delta VFD037CP43B-21 CP2000 Fan and Pump AC Drive, 3.7 kW / 5 HP, 3-Phase 460 V

Brand
Delta
Model number
VFD037CP43B-21

CP2000 drive for fans and pumps, 3.7 kW (5 HP) on 3-phase 460 V, 8.5 A light duty and 6.0 A normal duty, with multi-pump control, fire mode, built-in 10k-step PLC, Modbus and BACnet; frame A.

Price and availability on request

Request a quote

Sent with the product details: Delta VFD037CP43B-21 CP2000 Fan and Pump AC Drive, 3.7 kW / 5 HP, 3-Phase 460 V.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • With a built-in 10K steps Delta PLC allows user to execute distributional control and independent control when connecting to a network system. Delta CP2000 series drives provide you the intelligent control possibility beyond your imagination.
  • The calendar function allows user to program the PLC procedure, the ON/OFF in chronological order, the daylight saving time and etc.
  • A wide range of models to fulfill the demands of different industries.
  • The modularized design eases the maintenance and expansion.
  • High-speed communication interfaces with Modbus protocol and BACnet protocol built in. Diverse communication options are available for you: the BACnet IP, PROFINET, ProfiBUS-DP, the DeviceNet, the Modbus TCP, the Ethernet-IP and the CANopen Cards.
  • Special PCB coating design (Printed Circuit Board) for enhancing environmental tolerance.
  • Complied with global safety standards: CE, UL and cUL
  • Run fire mode while emergency to have uninterrupted smoke releasing and pressure adding
  • Multi pumps control at fixed amount, fixed time circulating control. Able to control 8 pumps at the same time. (Optional multi-control relay card is required.)

Specifications

Product
SeriesCP2000
Rating
Light duty motor output3.7 kW (5 HP)
Light duty rated output current8.5 A
Light duty rated output capacity6.8 kVA
Normal duty motor output2.2 kW (3 HP)
Normal duty rated output current6.0 A
Normal duty rated output capacity4.8 kVA
Overload toleranceLight duty: 120% of rated current for 1 minute during every 5 minutes; normal duty: 120% for 1 minute during every 5 minutes and 160% for 3 seconds during every 25 seconds
Input
Input current (light / normal duty)12.4 A / 8.7 A
Power supply capacity (light / normal duty)10.3 kVA / 7.2 kVA
Rated voltage / frequency3 phase, 380 ~ 480 VAC (-15% ~ +10%), 50/60 Hz
Operating voltage range323 ~ 528 VAC
Frequency tolerance47 ~ 63 Hz
Power factor> 0.98
Output
Carrier frequency2 ~ 15 kHz (default 8)
Max. output frequency599.00 Hz
Design
FrameA
Efficiency97.8%
Weight2.6 ±0.3 kg
Cooling methodFan cooling
Braking chopperBuilt-in
DC chokeOptional
EMC filterNo built-in (optional)
Protection levelIP20 / UL Type 1 / NEMA 1 with top cover (IP20 / UL Open Type with top cover removed)
Environment
Operation temperature-10 ~ 40 °C (-10 ~ 50 °C with top cover removed)
Ordering
VersionVersion B (rated output current values marked * in the catalog apply)
Delta India price listInbuilt PLC, Braking chopper, LCD Display unit (Delta price list 2026-27, July edition)
Control
Control methodV/F, SVC, PM Sensorless, SynRM Sensorless
Starting torqueUp to 150% or above at 0.5 Hz
V/F curve4 point adjustable V/F curve and square curve
Frequency setting signal0–+10 V, 4–20 mA, 0–20 mA
Accel./decel. time0.00–600.00 / 0.0–6000.0 seconds
CommunicationModbus communication (RS-485 RJ45) built in
STOSafe Torque Off (STO per EN 61800-5-2); EN IEC 62061 maximum SIL 2; EN 61508 SIL 2; EN ISO 13849-1, Cat.3/PL d
Restart after instantaneous power failureParameter setting up to 20 seconds
Applications
Typical applicationsFixed-displacement pumps (fix flow and fix time), building automation, factory automation, HVAC drives, cooling pumps, cooling towers and general motor applications.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.