Delta VFD022C43A-21 C2000 Plus Vector Control AC Drive, 2.2 kW / 3 HP, 3-Phase 460 V

Brand
Delta
Model number
VFD022C43A-21

C2000 Plus vector drive for 2.2 kW (3 HP) on 3-phase 460 V, 6 A heavy duty, with IM / PM / SynRM motor control, built-in 10k-step PLC and Safe Torque Off; frame A.

Price and availability on request

Request a quote

Sent with the product details: Delta VFD022C43A-21 C2000 Plus Vector Control AC Drive, 2.2 kW / 3 HP, 3-Phase 460 V.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Heavy-duty overload capability up to 150% / 60 sec. and 180% / 3 sec. at rated current; sensorless vector control of IM / PM / SynRM motors
  • IP55 fans, efficient heat sink and Class 3C3 conformal PCB coating
  • Built-in PLC (10k steps) and remote I/O integration for CANopen / Modbus master stations
  • Positioning control, master / slave torque control, electromagnetic energy traction control, and more
  • Communication cards (optional): EtherCAT, EtherNet/IP, DeviceNet, PROFINET, PROFIBUS DP, Modbus TCP, CANopen

Specifications

Product
SeriesC2000 Plus
Rating
Heavy duty (HD) motor power2.2 kW (3 HP)
Heavy duty (HD) rated output current6 A
Super heavy duty (SHD) motor power1.5 kW (2 HP)
Super heavy duty (SHD) rated output current4 A
Overload, heavy duty150% of rated output current for 1 min. in every 5 mins.; 180% for 3 secs. in every 30 secs.
Overload, super heavy duty150% of rated output current for 1 min. in every 5 mins.; 200% for 3 secs. in every 30 secs.
Input
Rated input current (HD / SHD)8.7 A / 5.9 A
Power supply capacity (HD / SHD)7.2 kVA / 4.9 kVA
Rated input voltage3Ø, 380 ~ 480 VAC (-15% ~ +10%), 50 / 60 Hz
Permissible power frequency variation±5% (47 ~ 63 Hz)
Displacement power factor (cosϕ)> 0.98
Design
FrameA
Efficiency97.8%
Cooling methodForced air-cooling
Braking chopperBuilt-in
DC reactorOptional
EMC filterOptional
EMC-COP01 (CANopen)Optional
Protection levelIP20 / UL Type 1 / NEMA 1 with top cover (IP20 / UL Open Type with top cover removed)
Environment
Operation temperature-10 °C ~ 40 °C (-10 °C ~ 50 °C with top cover removed)
Installation locationIEC60364-1 / IEC60664-1 Pollution degree 2, indoor use only
Storage / transportation temperature-25 ~ 70 °C
Altitude0 ~ 1000 m normal operation; 1000 ~ 2000 m: decrease 1% of rated current or lower 0.5 °C of temperature for every 100 m increase
Control
Control modesIMVF, IMVF + PG, IM/PM SVC, IMFOC + PG, PMFOC + PG, IMFOC Sensorless, PM Sensorless, IPM Sensorless, SynRM Sensorless, IM / PM TQCPG, IM TQC Sensorless, SynRM TQC Sensorless
Torque limitHeavy Duty: up to 180% torque current; Super Heavy Duty: up to 220% torque current
Speed control rangeIMVF, IMVF + PG, IMSVC: 1:50; IMFOC Sensorless: 1:100; IMFOC + PG: 1:1000
Starting torqueIMVF, IMVF + PG, IMSVC: 150% / 3 Hz; IMFOC Sensorless: 200% / 0.5 Hz; IMFOC + PG: 200% / 0 Hz
Motor overheat protectionSupports electronic thermal relay protection, PTC, KTY84-130 and PT100
Short-circuit current rating (SCCR)Per UL508C, the C2000 Plus with a fuse is suitable for power systems with less than 100kA short-circuit capacity
SafetySafe Torque Off (STO, EN/IEC61800-5-2); IEC62061/IEC61508, SIL CL2; EN ISO13849-1, Cat.3/PL d
Output
Max. output frequency0 ~ 599 Hz
Ordering
Delta India price listInbuilt PLC, Braking chopper, LCD Display unit (Delta price list 2026-27, July edition)
Applications
Typical applicationsExtruders, rubber millers, injection molding machines, pipe bending machines, conveyance systems, winding machines, bridge cranes, stage lifting systems, glass tempering furnaces, electromagnetic stirrers

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.