Delta VFD015EL21A VFD-EL Micro AC Drive, 1.5 kW / 2 HP, 1-Phase 230 V, Built-in EMC Filter

Brand
Delta
Model number
VFD015EL21A

VFD-EL micro drive for a 1.5 kW (2.0 HP) motor on a single-phase 230 V supply, 7.5 A rated output, 0.1 to 599 Hz, built-in EMC filter, PID control and RS-485 Modbus; frame B.

Price and availability on request

Request a quote

Sent with the product details: Delta VFD015EL21A VFD-EL Micro AC Drive, 1.5 kW / 2 HP, 1-Phase 230 V, Built-in EMC Filter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 3 points adjustable V/f curve
  • Built-in PID feedback control
  • RFI-switch for IT mains
  • Built-in EMI filter (for models 230V 1-phase and 460V 3-phase)
  • Use RS-485 communication interface (RJ-45) with Modbus protocol
  • Optional communication modules for multiple communication protocols, such as Profibus, DeviceNet, LonWorks and CANopen
  • Complete protection function

Specifications

Product
SeriesVFD-EL
Rating
Max. applicable motor output1.5 kW (2.0 HP)
Rated output capacity2.9 kVA
Rated output current7.5 A
Output
Maximum output voltage3-phase proportional to input voltage
Output frequency0.1 ~ 599 Hz
Carrier frequency2 ~ 12 kHz
Input
Rated input current15.7 A
Rated voltage / frequencySingle-phase, 200 ~ 240 V, 50 / 60 Hz
Voltage tolerance±10 % (180 ~ 264 V)
Frequency tolerance±5 % (47 ~ 63 Hz)
Design
Built-in EMC filterYes (230 V 1-phase and 460 V 3-phase models)
Cooling methodFan cooling
FrameB
Dimensions W × H × D100.0 × 174.0 × 136.0 mm
Weight1.7 kg
Control
Control systemSPWM (Sinusoidal Pulse Width Modulation) control (V/F control)
Torque characteristicsIncluding the auto-torque/auto-slip compensation; starting torque can be 150 % at 5.0 Hz
Overload endurance150 % of rated current for 1 minute
Accel/decel time0.1 to 600 seconds (2 independent settings for accel/decel time)
Regenerated braking torqueApprox. 20 % (up to 125 % possible with optional brake resistor)
Frequency setting (external signal)Potentiometer 5 k / 0.5 W, 0 to +10 VDC, 4 to 20 mA, RS-485 interface; multi-function inputs 3 to 6 (15 steps, Jog, up/down)
CommunicationRS-485 serial interface (Modbus)
Protection functionsOver voltage, over current, under voltage, external fault, overload, ground fault, overheating, electronic thermal, IGBT short circuit, PTC
Environment
Enclosure ratingIP20
Ambient temperature-10 °C ~ 50 °C (40 °C for side-by-side mounting), non-condensing and not frozen
Installation locationAltitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Ordering
Delta India price listInbuilt EMC filter, Non detachable display unit (Delta price list 2026-27, July edition)
Applications
Typical applicationsSmall size pump & fan, blowing machine, conveyer belt, simple DIY processing equipment

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.