Delta PMU-13V155WCCA 13.8V 151W Panel Mount Power Supply with Battery Backup, PMU Series

Brand
Delta
Model number
PMU-13V155WCCA

PMU panel mount power supply with battery charging and backup with 13.8V output (151W) from 90-132Vac or 180-264Vac. Aluminium and steel case and convection cooling, operating -20 to +70 °C. With a DC OK signal and battery backup.

Price and availability on request

Request a quote

Sent with the product details: Delta PMU-13V155WCCA 13.8V 151W Panel Mount Power Supply with Battery Backup, PMU Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • AC input voltage range selectable by switch
  • LED indicators for DC OK (Green) and Battery Reverse Polarity Connection (Red)
  • Zero switch-over time from loss of AC, to battery operation
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • High MTBF > 700,000 hrs per Telcordia SR-332
  • Monitoring Signals for AC OK, DC OK and Battery Low indication
  • Overvoltage / Overcurrent / Over temperature / Short circuit protections
  • Built-in over current and short circuit protection in Buffering (battery discharging) mode operation
  • Certified according to IEC/EN/UL 62368-1

Specifications

Product
SeriesPMU Series
MountingPanel mount
Output
Output Current9.5A,1.5A
Output Voltage13.8V
Output Voltage Adjustment Range12-14Vdc
Output Power151W
Line Regulation< 0.5% (90-132Vac @ 90% load,180-264Vac @ 100% load)
Load Regulation< 1.0% (90-132Vac @ 0-90% load,180-264Vac @ 0-100% load)
PARD< 150mVpp @ 0°C to -20°C / < 100mVpp @ > 0°C to 70°C
Start-up Time< 1,000ms (115Vac @ 90% load, 230Vac @ 100% load)
Hold-up Time> 20ms (115Vac @ 90% load, 230Vac @ 100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5%, 0-50% & 50-100% & 10-100% load / (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1KHz)
Start-up with Capacitive Loads3,600μF at 13.8V/11A
Voltage Drop Between Input and OutputNormal Mode: 0.5V typ. / Buffering Mode: 0.2V typ.
Rise Time< 50ms (100Vac @ 90% load, 200Vac @ 100% load)
Input
Nominal Input Voltage100-120Vac, 200-240Vac (Selectable by Switch)
Input Voltage Range90-132Vac, 180-264Vac (Selectable by Switch)
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current< 2.5A @ 115Vac, < 1.5A @ 230Vac
Efficiency at 100% load> 85.0% @ 115Vac / > 86.0% @ 230Vac
Inrush Current(Cold Start) / < 25A @ 115Vac & 230Vac
Leakage Current< 0.5mA @ 264Vac
Power DissipationNo Load: < 0.4W @ 115Vac, < 0.5W @ 230Vac / 100% Load: < 23W @ 115Vac & 230Vac
Mechanical
Case Chassis / CoverAL / SGCC
IndicatorLED Indicator: / Green LED: DC OK / Red LED: Battery Connected in Reverse Polarity
Cooling SystemConvection
Unit Weight0.60 kg (1.32 lb)
Dimensions178 x 97 x 38 mm / 7.01” x 3.82” x 1.50”
Environment
Operating Temperature-20°C to +70°C
Storage Temperature-40°C to +85°C
Power De-ratingI/P: 90-132Vac: / < 0°C to -20°C de-rate power by 2.25% / °C / 50°C to 70°C de-rate power by 2.25% / °C / I/P: 180-264Vac: / < 0°C to -20°C de-rate power by 2.5% / °C / 50°C to 70°C de-rate power by 2.5% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Bump Test (Operating)IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000 times per direction, 3000 times in total
Over Voltage CategoryII
Protections
OvervoltageV1: <18.5V, SELV Output, Hiccup mode, Non-latching (auto-recovery) / B+: 15Vdc Max will not cause damage to the unit
Overload / OvercurrentNormal Mode: 105-150% of rated load current, Hiccup mode, Non-Latching (Auto recovery) / Buffering Mode: 11.5-19.0A, Latch mode
Over TemperatureLatch mode
Short CircuitNormal Mode: Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed) / Buffering Mode: Latch mode
Protection Against ShockClass I with Primary Earth connection
Battery Polarity ProtectionYes (RED LED = ON)
Wrong Battery Voltage ProtectionYes, 15Vdc Max will not cause damage to the unit
Deep Discharge Protection9.0V ± 0.5V
Reliability
MTBF> 700,000 hrs. as per Telcordia SR-332 / I/P: 115Vac, Ta: 25°C / O/P: 13.8V/9.9A for 13V model and 27.6V/4.95A for 27V model
Expected Cap Life Time10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety
Electrical SafetySIQ Bauart: EN 60950-1, EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1, UL 62368-1 and CSA C22.2 No. 62368-1 / CB scheme: IEC 60950-1, IEC 62368-1 / CCC: GB/T 9254, GB 17625.1 and GB 4943.1 / BIS: IS 13252 (Part 1)
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0 KVac / Input to Ground: 1.5 KVac / Output to Ground: 0.5 KVac
Safety Entry Low VoltageSELV (IEC 60950-1)
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and / The Electromagnetic Compatibility Regulations 2016 No. 1091
BISIEC 60950-1, IS 13252 (Part 1)
EMC
EmissionGeneric Standards: CISPR 22, CISPR 32, EN/BS EN 55022, EN/BS EN 55032, FCC Title 47: Class B
ImmunityGeneric Standards: EN/BS EN 55024
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A, GB17625.1
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Battery Input / Output
Nominal Battery Voltage(Batteries not included with power supply) / 12Vdc / SLA Sealed lead acid battery
Battery Voltage RangeContinuously Operating: 11.0 to 13.8Vdc (nominal at 12V) / Maximum Allowed Voltage: 16Vdc Max / Minimum Voltage: 8.5Vdc
Battery Capacity3.3AH/ 7AH/ 12AH/ 15AH
Battery Charging Mode(Normal Mode) / CC-CV mode (constant current-constant voltage) at 0 to 1.5A
End of Charge VoltageThe unit always charges battery to a fixed voltage value

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.