Delta PMT-D2V75W2CA 5V / 24V 75.4W Dual Output Panel Mount Power Supply, PMT2 Series

Brand
Delta
Model number
PMT-D2V75W2CA

PMT2 panel mount power supply with 5V and 24V output (75.4W) from 90-264Vac. Aluminium and steel case and convection cooling, operating -30 to +70 °C. With household appliance approvals.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-D2V75W2CA 5V / 24V 75.4W Dual Output Panel Mount Power Supply, PMT2 Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Isolated & non-isolated Output & Ground for CH1 & CH2
  • Household appliance approvals to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
  • Universal AC input voltage range
  • No load power consumption < 0.3W
  • Low profile design : 30mm height
  • OVC III, Pollution Degree 3
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • High MTBF > 700,000 hrs per Telcordia SR-332

Specifications

Product
SeriesPMT2 Series
MountingPanel mount
Output
Output Current5A,2.1A
Output Voltage5V,24V
Output Voltage Adjustment RangeV1: Fixed; V2: 21.6 – 26.4V
Output Power75.4W
Line RegulationV1 & V2: ±0.5% typ. (@ 115Vac & 230Vac input)
Load RegulationV1: ±1.5% typ. V2: ±0.5% typ. (@ 115Vac & 230Vac input)
PARDV1: < 100mVpp, V2: < 150mVpp @ 0°C to 70°C / V1: 300mVpp,V2:450mVpp typ @ -30°C to 0°C
Start-up Time500ms typ. @ 115Vac & 230Vac
Hold-up Time10ms typ. @ 115Vac, 50ms typ. @ 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
Start-up with Capacitive LoadsV1 & V2: 8000uF Max
Rise Time30ms typ. @ 115Vac & 230Vac
Input
Nominal Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current1.4A typ. @ 115Vac, 0.85A typ. @ 230Vac
Efficiency at 100% load85% typ. @ 230Vac
Inrush Current55A typ. @ 230Vac
Leakage Current< 0.5mA @ 240Vac/50Hz
Mechanical
Case Chassis / CoverAluminium / SGCC
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input TerminalM3.5 x 7 Pins (Rated 300V/20A)
Noise Sound Pressure Level (SPL)< 25dBA
WireAWG 18-12 / Current rating can refer to page6 “Wire AWG Table”
Unit Weight0.276 kg (0.61 lb)
Dimensions129 x 97 x 30 mm / 5.08” x 3.82” x 1.18”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
Operating Temperature-30°C to +70°C (-40°C Cold Start)
Storage Temperature-40°C to +85°C
Power De-rating> 40°C de-rate power by 1.67% / °C / < 100Vac de-rate power by 1.33% / V / (86.67% load @ 90Vac)
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (0 to 16,400 ft)
Pollution Degree3
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Protections
OvervoltageV1: 5.5 - 7.5V; / V2: 26.4 - 33.6V ; / Latch Mode
Overload / OvercurrentV1 > 110% of rate load current, Hiccup Mode, Non-Latching (Auto-Recovery) / V2 >110% of rate load current, Hiccup Mode, Non-Latching (Auto-Recovery) / (when V2 auto-recovery, V1 auto-recovery)
Over TemperatureV1: Hiccup Mode, Non-Latching (Auto-Recovery) / V2: Latch (when V2 latch, V1 latch)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery) / (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE connection
Reliability
MTBF> 700,000 hrs as per Telcordia SR-332 / I/P: 230Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time10 years (230Vac, 50% load @ 40°C)
Safety
Electrical SafetyTUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 / cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 / KC: K 60950-1 / EAC: TP TC 004/2011 / BSMI: CNS 14336-1 / BIS: 13252 (Part 1) / CCC: GB 4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground:1.25 KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
EMC
Emission(CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32 / Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B
ImmunityEN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 / Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.