Delta PMT-D1V75W2CA 5V / 12V 73W Dual Output Panel Mount Power Supply, PMT2 Series
- Brand
- Delta
- Model number
- PMT-D1V75W2CA
PMT2 panel mount power supply with 5V and 12V output (73W) from 90-264Vac. Aluminium and steel case and convection cooling, operating -30 to +70 °C. With household appliance approvals.
Price and availability on request
Key features
- Isolated & non-isolated Output & Ground for CH1 & CH2
- Household appliance approvals to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
- Universal AC input voltage range
- No load power consumption < 0.3W
- Low profile design : 30mm height
- OVC III, Pollution Degree 3
- Conforms to harmonic current IEC/EN 61000-3-2, Class A
- High MTBF > 700,000 hrs per Telcordia SR-332
Specifications
| Series | PMT2 Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 5A,4A |
|---|---|
| Output Voltage | 5V,12V |
| Output Voltage Adjustment Range | V1: Fixed; V2: 10.8 – 13.2V |
| Output Power | 73W |
| Line Regulation | V1 & V2: ±0.5% typ. (@ 115Vac & 230Vac input) |
| Load Regulation | V1: ±1.5% typ. V2: ±0.5% typ. (@ 115Vac & 230Vac input) |
| PARD | V1: <100mVpp, V2: <120mVpp @ 0°C to 70°C / V1: 300mVpp,V2:360mVpp typ @ -30°C to 0°C |
| Start-up Time | 500ms typ. @ 115Vac & 230Vac |
| Hold-up Time | 10ms typ. @ 115Vac, 50ms typ. @ 230Vac |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
| Start-up with Capacitive Loads | V1 & V2 : 8000uF Max |
| Rise Time | 30ms typ. @ 115Vac & 230Vac |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | 1.4A typ. @ 115Vac, 0.85A typ. @ 230Vac |
| Efficiency at 100% load | 83% typ. @ 230Vac |
| Inrush Current | 55A typ. @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac/50Hz |
| Case Chassis / Cover | Aluminium / SGCC |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | M3.5 x 7 Pins (Rated 300V/20A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Wire | AWG 18-12 / Current rating can refer to page6 “Wire AWG Table” |
| Unit Weight | 0.276 kg (0.61 lb) |
| Dimensions | 129 x 97 x 30 mm / 5.08” x 3.82” x 1.18” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
|---|---|
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30°C to +70°C (-40°C Cold Start) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 40°C de-rate power by 1.67% / °C / < 100Vac de-rate power by 1.33% / V / (86.67% load @ 90Vac) |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Pollution Degree | 3 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
| Overvoltage | V1: 5.5 - 7.5V; / V2: 13.2 - 17.4V ; / Latch Mode |
|---|---|
| Overload / Overcurrent | V1 > 110% of rate load current, Hiccup Mode, Non-Latching (Auto-Recovery) / V2 >110% of rate load current, Hiccup Mode, Non-Latching (Auto-Recovery) / (when V2 auto-recovery, V1 auto-recovery) |
| Over Temperature | V1: Hiccup Mode, Non-Latching (Auto-Recovery) / V2: Latch (when V2 latch, V1 latch) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery) / (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with PE connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 / I/P: 230Vac, O/P: 100% Load, Ta: 25°C) |
|---|---|
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16 / UL/cUL: UL 62368-1, and CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16, / KC: K 60950-1 / EAC: TP TC 004/2011 / BIS: 13252 (Part 1) / CCC: GB 4943.1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground:1.25 KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32 / Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
|---|---|
| Immunity | EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 / Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.