Delta PMT-5V350W1AM 5V 60A 300W Panel Mount Power Supply, PMT Series

Brand
Delta
Model number
PMT-5V350W1AM

PMT panel mount power supply with 5V 60A output (300W) from 90-132Vac or 180-264Vac. Aluminium case and fan cooling, operating -20 to +70 °C.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-5V350W1AM 5V 60A 300W Panel Mount Power Supply, PMT Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • AC input range selectable by switch
  • Full Aluminum casing for light weight and corrosion resistant handling
  • Built-in automatic fan speed control circuit
  • Wide operating temperature range from -20°C to +70°C and cold start at -40°C
  • MTBF > 700,000 hrs as per Telcordia SR-332
  • Short Circuit / Overvoltage / Overload / Over Temperature Protections

Specifications

Product
SeriesPMT Series
MountingPanel mount
Output
Output Current60A
Output Voltage5V
Output Voltage Adjustment Range4.50-5.50Vdc
Output Power300W
Line Regulation± 0.5% typ
Load Regulation± 2.5% typ
PARD< 150mVpp
Start-up Time< 1000ms @ nominal input (100% load)
Hold-up Time> 16ms @ 115Vac, / > 20 ms @ 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 1000mVpp @ 10-50% load and 50-100% load
Start-up with Capacitive Loads8,000µF Max
Input
Nominal Input Voltage100-120Vac, 200-240Vac (Selectable by Switch)
Input Voltage Range90-132Vac, 180-264Vac (Selectable by Switch)
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current< 7.00A @ 115Vac, / < 4.00A @ 230Vac
Efficiency at 100% load> 76.0% @ 230Vac
Inrush Current< 40A @ 115Vac, / < 60A @ 230Vac
Leakage Current< 3.5mA @ 240Vac
Mechanical
Case Chassis / CoverAluminium
Cooling SystemForced Cooling
Unit Weight0.81 kg (1.79 lb)
Dimensions215 x 115 x 50 mm / 8.46” x 4.53” x 1.97”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S? (2.5G peak); 90 min per axis for all X, Y, Z direction
Operating Temperature-20°C to +70°C
Storage Temperature-40°C to +85°C
Power De-rating> 50°C de-rate power by 4% /°C / > 60°C de-rate power by 1% /°C / < 100Vac de-rate power by 3%/V, / < 200Vac de-rate power by 1.5%/V
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms peak; 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (0 to 16,400 ft)
Pollution Degree2
Over Voltage CategoryII
Protections
Overvoltage< 5.75~7.50V, SELV Output, Latch Mode
Overload / Overcurrent> 105~175% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
Over TemperatureHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
Short CircuitHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF> 700,000 hrs. as per Telcordia SR-332
Safety
Electrical SafetyUL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File no. E131881), CB scheme to IEC 60950-1
Galvanic IsolationInput to Output: 3.0KVac / Input to Ground: 1.5KVac / Output to Ground: 0.5KVac
Safety Entry Low VoltageSELV (EN 60950-1)
Material and PartsRoHS Directive 2011/65/EU Compliant
EMC
EmissionCISPR32, EN55032, FCC Title 47: Class A (Test with Delta EMI filter P/N: 10DKAW5)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.