PMT2 panel mount power supply with 48V 12.5A output (600W) from 90-132Vac or 180-264Vac. Steel case and fan cooling, operating -40 to +70 °C.
Price and availability on request
Key features
- AC input voltage range selectable by switch (90-132Vac, 180-264Vac)
- 300 Vac input surge resilience (5s)
- Built-in 200% peak power supported
- Low profile design: 41mm height
- Certified to IEC/EN 62368-1
- Wide operating temp -40°C ~ 70°C
Specifications
| Series | PMT2 Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 12.5A |
|---|---|
| Output Voltage | 48V |
| Output Voltage Adjustment Range | 43.2-54Vdc |
| Output Power | 600W |
| Line Regulation | ± 0.5% typ. @ 100-132Vac, 200-264Vac (Selectable by Switch) |
| Load Regulation | ±0.5% @ 100-132Vac, 200-264Vac (Selectable by Switch) |
| PARD | < 360mVpp @ 0°C to 70°C / 1080mVpp typ. @ -30°C to 0°C |
| Start-up Time | 500 ms typ. @ 115 Vac & 230 Vac |
| Hold-up Time | 16 ms typ. @ 115 Vac & 20 ms typ. @ 230 Vac |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 & 230Vac input, 50-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 120Hz & 1KHz) |
| Start-up with Capacitive Loads | 5,000µF Max |
| Rise Time | 30ms typ. @ 115Vac & 230Vac |
| Nominal Input Voltage | 100-120Vac, 200-240Vac (Selectable by Switch) |
|---|---|
| Input Voltage Range | 90-132Vac, 180-264Vac (Selectable by Switch) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | 12A typ. @ 115Vac, 7.5A typ. @ 230Vac |
| Efficiency at 100% load | 92% typ. @ 230Vac |
| Inrush Current | 60A typ. @ 230Vac (Cold Start) |
| Leakage Current | < 0.75mA @ 240Vac |
| Case Chassis / Cover | SGCC |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Force Cooling |
| Wire | AWG 18-12 / Current rating can refer to page 6 “Wire AWG Table” |
| Unit Weight | 1.10 kg (2.43 lb) |
| Dimensions | 225 x 124 x 41 mm / 8.86” x 4.88” x 1.61” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz (2G); 10min per cycle, 60min for each axis (X, Y, Z) |
|---|---|
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2% / °C / < 100Vac de-rate power by 2% / V / <200 Vac de-rate power by 1% / V / (80% load @ 90 Vac & 180 Vac) |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Pollution Degree | 3 |
| Over Voltage Category | II |
| Overvoltage | 54.2-64.8V SELV Output, Latch Mode |
|---|---|
| Overload / Overcurrent | 110-175% of rated load current, >5s into latch mode / (200% peak power for 5 seconds) |
| Over Temperature | Hiccup Mode, Non-Latching (Auto-Recovery) |
| Short Circuit | Latch mode |
| Protection Against Shock | Class I with PE* 6 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 100Vac, O/P: 100% Load, Ta: 25°C) |
|---|---|
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) |
| Electrical Safety | PMT-48V350W2BR: / TUV Bauart: EN 62368-1 / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1; AS/NZS 62368-1 RCM / CQC: GB4943.1 / BIS: IS 13252 (Part 1) / BSMI: CNS 15598-1 / EAC: TP TC 004/2011 / UKCA: BS EN 62368-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU / This power supply does not comply with the harmonic current emission requirements specified in BS EN/EN61000-3-2. / Please ensure it is not used in applications where compliance with this standard is required. |
| Galvanic Isolation | Input to Output: 3.75 KVac / Input to Ground: 2.0 KVac / Output to Ground: 0.5 KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Emission | (CE & RE) / EN/BS EN 55032, AS/NZS CISPR 32 Class A, KS C 9832 / Compliance to FCC Part 15 Title 47 class A, ASNI C63.4 |
|---|---|
| Immunity | EN/BS EN 55035, KS C 9835 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.