Delta PMT-24V35W1AA 24V 1.46A 35W Panel Mount Power Supply, PMT Series

Brand
Delta
Model number
PMT-24V35W1AA

PMT panel mount power supply with 24V 1.46A output (35W) from 85-264Vac. Aluminium and steel case and convection cooling, operating -10 to +50 °C.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-24V35W1AA 24V 1.46A 35W Panel Mount Power Supply, PMT Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage range
  • Power will not de-rate from input voltage 90Vac to 264Vac
  • High MTBF > 700,000 hrs per Telcordia SR-332
  • Short Circuit / Overvoltage / Overload / Over Temperature Protections
  • Versatile connector options (Terminal Block, Front Face, Harness)

Specifications

Product
SeriesPMT Series
MountingPanel mount
Output
Output Current1.46A
Output Voltage24V
Output Voltage Adjustment Range22-28Vdc
Output Power35W
Line Regulation< 0.5%typ. (@ 85-264Vac input, 100%load)
Load Regulation< 1%typ. (@ 85-264Vac input, 0 to 100% load)
PARD< 100mVpp @ 0°C to 50°C, / < 150mVpp @ -10°C to 0°C
Start-up Time< 2500ms @ nominal input (100% load)
Hold-up Time> 16.7ms @ 115Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 0-100% load (Slew Rate: 0.1A/µS)
Start-up with Capacitive Loads8,000µF Max
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current< 0.75A @ 115Vac, / < 0.50A @ 230Vac
Efficiency at 100% load> 85.0% @ 115Vac & 230Vac
Inrush Current< 30A @ 115Vac, / < 60A @ 230Vac
Leakage Current< 1mA @ 240Vac
Mechanical
Case Chassis / CoverSGCC / Aluminium
Cooling SystemConvection
Unit Weight0.22 kg (0.49 lb)
Dimensions98 x 98 x 38 mm / 3.86” x 3.86” x 1.50”
Environment
Operating Temperature-10°C to +50°C
Storage Temperature-25°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% /°C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII
Protections
Overvoltage< 32V, ±10%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
Over TemperatureNon-Latching (Auto-Recovery)
Short CircuitHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE* connection
Reliability
MTBF> 700,000 hrs. as per Telcordia SR-332 / (I/P: 100Vac, O/P: 100% Load, Ta: 35°C)
Safety
Electrical SafetyTUV Bauart :EN 60950-1, EN 62368-1 / UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme :IEC 60950-1, IEC 62368-1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0 KVac / Input to Ground: 1.5 KVac / Output to Ground: 0.5 KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
EMC
Emission(CE & RE) / CISPR 32, EN/BS EN 55032, FCC Title 47: Class B
ImmunityEN/BS EN 55024

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.