PMT panel mount power supply with 24V 14.6A output (350.4W) from 90-132Vac or 180-264Vac. Aluminium case and fan cooling, operating -10 to +70 °C.
Price and availability on request
Key features
- AC input voltage range selectable by switch
- Full Aluminium casing for light weight and corrosion resistant handling
- Built-in automatic fan speed control circuit
- MTBF > 700,000 hrs as per Telcordia SR-332
- Short Circuit / Overvoltage / Overload / Over Temperature Protections
Specifications
| Series | PMT Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 14.6A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 20.0-26.4Vdc |
| Output Power | 350.4W |
| Line Regulation | ± 0.5% typ. |
| Load Regulation | ± 0.5% typ. |
| PARD | < 150mVpp |
| Start-up Time | < 1000ms @ nominal input (100% load) |
| Hold-up Time | > 16ms @ 115Vac, / > 20ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 10-50% load and 50-100% load |
| Start-up with Capacitive Loads | 8,000µF Max |
| Rise Time | < 50ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-120Vac, 200-240Vac (Selectable by Switch) |
|---|---|
| Input Voltage Range | 90-132Vac, 180-264Vac (Selectable by Switch) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | < 7.00A @ 115Vac, / < 4.00A @ 230Vac |
| Efficiency at 100% load | > 87.0% @ 230Vac |
| Inrush Current | < 50A @ 115Vac, / < 60A @ 230Vac |
| Leakage Current | < 3.5mA @ 240Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Forced Cooling |
| Noise Sound Pressure Level (SPL) | < 52dBA |
| Wire | AWG 20-12 |
| Unit Weight | 0.82 kg (1.81 lb) |
| Dimensions | 215 x 115 x 50 mm / 8.46” x 4.53” x 1.97” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S? (2.5G peak); 90 min per axis for all X, Y, Z direction |
|---|---|
| Operating Temperature | -10°C to +70°C |
| Storage Temperature | -25°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2.5% / °C / < 100Vac de-rate power by 3% / V / < 200Vac de-rate power by 3% / V |
| Operating Humidity | 5-95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms peak; 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II |
| Overvoltage | < 32.4V, SELV Output, Latch Mode |
|---|---|
| Overload / Overcurrent | < 25A of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Short Circuit | Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 |
|---|---|
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart: EN 60950-1, EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme: IEC 60950-1, IEC 62368-1 / BIS IS 13252 (for PMT-24V3501AK) |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 3.0KVac / Input to Ground: 1.5KVac / Output to Ground: 0.5KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 55011, FCC Title 47: Class B |
|---|---|
| Immunity | EN/BS EN 55024 |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.