Delta PMT-24V350W1AG 24V 14.6A 350.4W Panel Mount Power Supply, PMT Series

Brand
Delta
Model number
PMT-24V350W1AG

PMT panel mount power supply with 24V 14.6A output (350.4W) from 90-132Vac or 180-264Vac. Aluminium case and fan cooling, operating -10 to +70 °C.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-24V350W1AG 24V 14.6A 350.4W Panel Mount Power Supply, PMT Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • AC input voltage range selectable by switch
  • Full Aluminium casing for light weight and corrosion resistant handling
  • Built-in automatic fan speed control circuit
  • MTBF > 700,000 hrs as per Telcordia SR-332
  • Short Circuit / Overvoltage / Overload / Over Temperature Protections

Specifications

Product
SeriesPMT Series
MountingPanel mount
Output
Output Current14.6A
Output Voltage24V
Output Voltage Adjustment Range20.0-26.4Vdc
Output Power350.4W
Line Regulation± 0.5% typ
Load Regulation± 0.5% typ.
PARD< 150mVpp @ 25°C
Start-up Time< 1000ms @ nominal input (100% load, 25°C)
Hold-up Time> 16ms @ 115Vac, / > 20ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 10-50% load and 50-100% load
Start-up with Capacitive Loads8,000µF Max
Rise Time< 50ms @ nominal input (100% load)
Input
Nominal Input Voltage100-120Vac, 200-240Vac (Selectable by Switch)
Input Voltage Range90-132Vac, 180-264Vac (Selectable by Switch)
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current< 7.00A @ 115Vac, / < 4.00A @ 230Vac
Efficiency at 100% load> 87.0% @ 230Vac
Inrush Current< 50A @ 115Vac, / < 60A @ 230Vac
Leakage Current< 3.5mA @ 240Vac
Mechanical
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK)
Cooling SystemForced Cooling
Noise Sound Pressure Level (SPL)< 52dBA
WireAWG 20-12
Unit Weight0.82 kg (1.81 lb)
Dimensions215 x 115 x 50 mm / 8.46” x 4.53” x 1.97”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S? (2.5G peak); 90 min per axis for all X, Y, Z direction
Operating Temperature-10°C to +70°C
Storage Temperature-25°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% / °C / < 100Vac de-rate power by 3% / V / < 200Vac de-rate power by 3% / V
Operating Humidity5-95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC60068-2-27, 50G for a duration of 11ms, / 3 times per direction, 18 times in total
Vibration (Non-Operating)IEC60068-2-6, Random: 5Hz to 500Hz @ 2.09G peak; 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII
Protections
Overvoltage< 32.4V, SELV Output, Latch Mode
Overload / Overcurrent< 25A of rated load current, Hicc-up Mode, / Non-Latching (Auto-Recovery)
Over TemperatureHicc-up Mode, Non-Latching / (Auto-Recovery when the fault is removed)
Short CircuitHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIPX0
Protection Against ShockClass I with PE connection
Reliability
MTBF> 700,000 Hrs. as per Telcordia SR-332
Safety
Electrical SafetyUL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881) / CB scheme: UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) IEC 60950-1, IEC 62368-1
Galvanic IsolationInput to Output: 3.0 KVac / Input to Ground: 1.5 KVac / Output to Ground: 0.5 KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016
EMC
Emission(CE & RE) / CISPR 32, EN/BS EN 55032, FCC Title 47: Class A (With Delta EMI filter P/N: 10DKAW5)
ImmunityEN/BS EN 55024
Harmonic Current EmissionsNA

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.