Delta PMT-24V100W2BNJ 24V 4.5A 108W Panel Mount Power Supply, PMT2 ECO (High Line) Series

Brand
Delta
Model number
PMT-24V100W2BNJ

PMT2 ECO (High Line) panel mount power supply with 24V 4.5A output (108W) from 180-264 Vac. Aluminium and steel case and convection cooling, operating -40 to +70 °C.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-24V100W2BNJ 24V 4.5A 108W Panel Mount Power Supply, PMT2 ECO (High Line) Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • High line nominal input voltage 200-240 Vac
  • Low profile design: 30 mm height
  • OVC III, Pollution Degree 3
  • Wide operating temperature range of -40°C ~70°C
  • High MTBF > 700,000 hrs per Telcordia SR-332

Specifications

Product
SeriesPMT2 ECO (High Line) Series
MountingPanel mount
Output
Output Current4.5A
Output Voltage24V
Output Voltage Adjustment Range21.6-26.4 Vdc
Output Power108W
Line Regulation± 0.5% (@ 230 Vac input)
Load Regulation± 0.5% (@ 230 Vac input)
PARD< 150 mVpp @ 0°C to 70°C / 450 mVpp typ. @ -30°C to 0°C
Start-up Time500 ms typ. @ 230 Vac
Hold-up Time42 ms typ. @ 230 Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz)
Start-up with Capacitive Loads8,000µF Max
Rise Time30 ms typ. @ 230 Vac
Input
Nominal Input Voltage200-240 Vac
Input Voltage Range180-264 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
Input Current1.2 A typ. @ 230 Vac
Efficiency at 100% load89.0% typ.
Inrush Current55 A typ. @ 230 Vac
Leakage Current< 0.5 mA @ 240 Vac
Mechanical
Case Chassis / CoverSGCC / Aluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input TerminalM3.5 x 7 Pins (Rated 300 V / 20 A)
Noise Sound Pressure Level (SPL)< 25dBA
WireAWG 18-12 / Current rating can refer to page 6 “Wire AWG Table”
Unit Weight0.285 kg (0.63 lb)
Dimensions129 x 97 x 30 mm / 5.08” x 3.82” x 1.18”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 20 Hz to 500 Hz (5G); 10 min per cycle, 60 min for each axis (X, Y,Z)
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for each 3 directions
Operating Temperature-40°C to +70°C
Storage Temperature-40°C to +85°C
Power De-rating> 50°C de-rate power by 2% / °C
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree3
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Protections
Overvoltage26.4 V-33.6 V / SELV Output, Latch Mode
Overload / Overcurrent110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF> 700,000 hrs as per Telcordia SR-332 (I/P: 230Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time10 years (230Vac, 50% load @ 40°C)
Safety
Electrical SafetyCB scheme: IEC 62368-1 / CCC: GB 4943.1 / BIS: IS 13252 (Part 1)
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 1.25 KVac
Safety Entry Low VoltageSELV
EMC
Emission(CE & RE) / CISPR 32, EN 55032, Class A
ImmunityEN 55035
Harmonic Current EmissionsIEC/EN 61000-3-2, Class A

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.