Delta PMT-15V50W1AG 15V 3.4A 51W Panel Mount Power Supply, PMT Series
- Brand
- Delta
- Model number
- PMT-15V50W1AG
PMT panel mount power supply with 15V 3.4A output (51W) from 85-264Vac. Aluminium and steel case and convection cooling, operating -10 to +70 °C.
Price and availability on request
Key features
- Universal AC input voltage range
- Power will not de-rate from input voltage 100Vac to 264Vac
- High MTBF > 700,000 hrs per Telcordia SR-332
- Short Circuit / Overvoltage / Overload / Over Temperature Protections
- Versatile connector options (Terminal Block, Front Face, Harness)
Specifications
| Series | PMT Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 3.4A |
|---|---|
| Output Voltage | 15V |
| Output Voltage Adjustment Range | 13.5-16.5Vdc |
| Output Power | 51W |
| Line Regulation | < 0.5% typ. (@ 115Vac & 230Vac input, 100% input) |
| Load Regulation | < 0.5% typ. (@ 115Vac & 230Vac input, 0-100% input) |
| PARD | < 150mVpp @ 25°C to 50°C, / < 300mVpp @ -10°C to 0°C |
| Start-up Time | 1,200ms typ.@ 115Vac, / 500ms typ. @ 230Vac (100% load) |
| Hold-up Time | 20ms typ. @ 115Vac, 100ms typ. @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% (1000mVp-p)@ 0-100% load (Slew Rate: 0.1A/µS) |
| Start-up with Capacitive Loads | 8,000μF Max |
| Rise Time | < 30ms @ 115Vac & 230Vac (100% load) |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | < 1.10A @ 115Vac, < 0.65A @ 230Vac |
| Efficiency at 100% load | 85.5% typ. @ 230Vac |
| Inrush Current | 45A typ. @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Case Chassis / Cover | Aluminium / SGCC |
|---|---|
| Cooling System | Convection |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Unit Weight | 0.23 kg (0.51 lb) |
| Dimensions | 98 x 98 x 38 mm / 3.86” x 3.86” x 1.50” |
| Operating Temperature | -10°C to +70°C |
|---|---|
| Storage Temperature | -25°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2.5% / °C / < 100Vac de-rate power by 1.33% / V / (80% load @ 85Vac) |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Pollution Degree | 2 |
| Over Voltage Category | II |
| Overvoltage | 17.25-20.25V, SELV Output, Hiccup Mode, / Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | 110-150% of rated load current, Hiccup Mode, / Non-Latching (Auto-Recovery) |
| Over Temperature | Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching / (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 100Vac, O/P: 100% Load, Ta: 35°C) |
|---|---|
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart:EN 60950-1, EN/BS EN 62368-1 / UL/cUL recognized:UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme:IEC 60950-1, IEC 62368-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 3.0KVac / Input to Ground: 1.5KVac / Output to Ground: 0.5KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN /BS EN 55032, FCC Title 47: Class B |
|---|---|
| Immunity | EN/BS EN 55024 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.