Delta PMT-15V100W2BA 15V 7A 105W Panel Mount Power Supply, PMT2 Series

Brand
Delta
Model number
PMT-15V100W2BA

PMT2 panel mount power supply with 15V 7A output (105W) from 90-264Vac. Aluminium and steel case and convection cooling, operating -30 to +70 °C. With SEMI F47 compliance and household appliance approvals.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-15V100W2BA 15V 7A 105W Panel Mount Power Supply, PMT2 Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Household appliance approvals according to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
  • Universal AC input voltage range
  • No load power consumption < 0.3W
  • Low profile design : 30mm height
  • OVC III, Pollution Degree 3
  • Wide operating temp -30°C ~ 70°C (Support -40°C cold start)
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • High MTBF > 700,000 hrs per Telcordia SR-332
  • Compliance with SEMI-F47

Specifications

Product
SeriesPMT2 Series
MountingPanel mount
Output
Output Current7A
Output Voltage15V
Output Voltage Adjustment Range13.5-16.5Vdc
Output Power105W
Line Regulation± 0.5% (@ 115Vac & 230Vac input)
Load Regulation± 0.5% (@ 115Vac & 230Vac input)
PARD< 120mVpp @ 0°C to 70°C, / 360mVpp typ. @ -30°C to 0°C
Start-up Time500ms typ. @ 115Vac & 230Vac (100% load)
Hold-up Time9ms typ. @ 115Vac, 42ms typ. @ 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
Start-up with Capacitive Loads8,000µF Max
Rise Time30ms typ. @ 115Vac & 230Vac
Input
Nominal Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current1.9A typ. @ 115Vac, 1.2A typ. @ 230Vac
Efficiency at 100% load88.0% typ. @ 230Vac
Inrush Current55A typ. @ 230Vac (Cold Start)
Leakage Current< 0.5mA @ 240Vac
Mechanical
Case Chassis / CoverAluminium / SGCC
IndicatorGreen LED (DC OK)
Cooling SystemConvection
WireWire AWG 18-12 / Current rating can refer to page 6 “Wire AWG Table”
Unit Weight0.285 kg (0.63 lb)
Dimensions129 x 97 x 30 mm / 5.08” x 3.82” x 1.18”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); / 10min per cycle, 60min for each axis (X, Y,Z)
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
Operating Temperature-30°C to +70°C (-40°C Cold Start)
Storage Temperature-40°C to +85°C
Power De-rating> 50°C de-rate power by 2% / °C / < 115Vac de-rate power by 0.6% / V / (85% load @ 90Vac)
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); / 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree3
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Protections
Overvoltage16.5V-21.0V SELV Output, Latch Mode
Overload / Overcurrent110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE*4 connection
Reliability
MTBF> 700,000 hrs as per Telcordia SR-332 / I/P: 230Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time10 years (230Vac, 50% load @ 40°C)
Safety
Electrical SafetyTUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 / cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 / KC: K 60950-1 / EAC: TP TC 004/2011 / BSMI: CNS 14336-1 / BIS: 13252 (Part 1) / CCC: GB 4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output:4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground:1.25 KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
EMC
Emission(CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 / Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B
ImmunityEN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 / Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.