Delta PMT-12V50W1AA 12V 4.17A 50W Panel Mount Power Supply, PMT Series
- Brand
- Delta
- Model number
- PMT-12V50W1AA
PMT panel mount power supply with 12V 4.17A output (50W) from 90-264Vac. Aluminium and steel case and convection cooling, operating -10 to +70 °C.
Price and availability on request
Key features
- Universal AC input voltage range
- Power will not de-rate from input voltage 90Vac to 264Vac
- High MTBF > 700,000 hrs per Telcordia SR-332
- Short Circuit / Overvoltage / Overload / Over Temperature Protections
- Versatile connector options (Terminal Block, Front Face, Harness)
Specifications
| Series | PMT Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 4.17A |
|---|---|
| Output Voltage | 12V |
| Output Voltage Adjustment Range | 11-14Vdc |
| Output Power | 50W |
| Line Regulation | < 0.5%typ. (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1%typ. (@ 85-264Vac input, 0-100% load) |
| PARD | < 100mVpp @ 0°C to 50°C, / < 150mVpp @ -10°C to 0°C |
| Start-up Time | < 2500ms @ nominal input (100% load) |
| Hold-up Time | > 16.7ms @ 115Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 0-100% load (Slew Rate: 0.1A/µS) |
| Start-up with Capacitive Loads | 8,000µF Max |
| Rise Time | < 30ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | < 1.10A @ 115Vac, / < 0.70A @ 230Vac |
| Efficiency at 100% load | > 83.0% @ 115Vac & 230Vac |
| Inrush Current | < 30A @ 115Vac, / < 60A @ 230Vac |
| Power Factor at 100% load | Conform to EN61000-3-2 |
| Leakage Current | < 1mA @ 240Vac |
| Case Chassis / Cover | SGCC / Aluminium |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.23 kg (0.51 lb) |
| Dimensions | 98 x 98 x 38 mm / 3.86” x 3.86” x 1.50” |
| Operating Temperature | -10°C to +70°C |
|---|---|
| Storage Temperature | -25°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2.5% /°C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
| Vibration (Non-Operating) | IEC60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II |
| Overvoltage | 16V, +10% / -5%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | > 120% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Non-Latching (Auto-Recovery) |
| Short Circuit | Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Degree of Protection | IPX0 |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 / (I/P: 100Vac, O/P: 100% Load, Ta: 35°C) |
|---|---|
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart :EN 60950-1, EN 62368-1 / UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme :IEC 60950-1, IEC 62368-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 3.0 KVac / Input to Ground: 1.5 KVac / Output to Ground: 0.5 KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, FCC Title 47: Class B |
|---|---|
| Immunity | EN/BS EN 55024 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.