Delta PMT-12V350W2BMB 12V 29A 348W Panel Mount Power Supply, PMT2 Series

Brand
Delta
Model number
PMT-12V350W2BMB

PMT2 panel mount power supply with 12V 29A output (348W) from 90-132Vac or 180-264Vac or 127-375Vdc. Steel case and fan cooling, operating -40 to +70 °C.

Price and availability on request

Request a quote

Sent with the product details: Delta PMT-12V350W2BMB 12V 29A 348W Panel Mount Power Supply, PMT2 Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • AC input voltage range selectable by switch (90-132Vac, 180-264Vac)
  • No load power consumption < 0.75W
  • Low profile design: 30mm height
  • High MTBF > 700,000 hrs per Telcordia SR-332
  • 150% Peak power supported as option
  • Wide operating temp -40°C ~ 70°C

Specifications

Product
SeriesPMT2 Series
MountingPanel mount
Output
Output Current29A
Output Voltage12V
Output Voltage Adjustment Range10.8-13.2Vdc
Output Power348W
Line Regulation± 0.5% typ. @ 100-132Vac, 180-264Vac (Selectable by Switch)
Load Regulation±1% @ 100-132Vac, 180-264Vac (Selectable by Switch)
PARD< 150mVpp @ 0°C to 70°C / 450mVpp typ. @ -30°C to 0°C
Start-up Time1500ms typ. @ 115Vac & 230Vac
Hold-up Time20ms typ. @ 115Vac & 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
Start-up with Capacitive Loads8,000µF Max
Rise Time30ms typ. @ 115Vac & 230Vac
Input
Nominal Input Voltage100-120Vac, 200-240Vac (Selectable by Switch)
Input Voltage Range90-132Vac, 180-264Vac (Selectable by Switch)
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range127-375Vdc
Input Current6A typ. @ 115Vac, 3.4A typ. @ 230Vac
Efficiency at 100% load84.5% typ. @ 230Vac
Inrush Current60A typ. @ 230Vac (Cold Start)
Leakage Current< 0.75mA @ 240Vac/50Hz
Mechanical
Case Chassis / CoverSGCC
IndicatorGreen LED (DC OK)
Cooling SystemForce Cooling
WireAWG 18-12 / Current rating can refer to page 6 “Wire AWG Table”
Unit Weight0.833 kg (1.84 lb)
Dimensions215 x 115 x 30 mm / 8.46” x 4.53” x 1.18”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
Operating Temperature-40°C to +70°C
Storage Temperature-40°C to +85°C
Power De-rating> 50°C de-rate power by 2% / °C / < < 100Vac de-rate power by 2% / V / (80% load @ 90Vac)
Operating Humidity20 to 90% (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (0 to 16,400 ft)
Pollution Degree2
Over Voltage CategoryII
Protections
Overvoltage13.2V-17.4V SELV Output, Latch Mode
Overload / Overcurrent110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE* 6 connection
Reliability
MTBF> 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time10 years (230Vac, 50% load @ 40°C)
Safety
Electrical SafetyPMT-12V350W2BR: / TUV Bauart: EN 62368-1 / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60950-1 / KC: K 60950-1 / EAC: TP TC 004/2011 / BSMI: CNS 14336-1 / BIS: IS 13252 (Part 1) / CCC: GB 4943.1 / / PMT-12V350W2BM: / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60950-1 / EAC: TP TC 004/2011 / CQC: GB4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU / This power supply does not comply with the harmonic current emission requirements specified in BS EN/EN61000-3-2. Please ensure it is not used in applications where compliance with this standard is required.
Galvanic IsolationInput to Output: 3.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 0.5 KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
EMC
Emission(CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 / Compliance to FCC Title 47, EN/BS EN 61000-6-3 : Class B
ImmunityEN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 61000-6-1

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.