Delta PMS-24V2K5W1BTD 24V 0-104.2A 2500W Panel Mount Power Supply, PMS Series

Brand
Delta
Model number
PMS-24V2K5W1BTD

PMS panel mount power supply with 24V 0-104.2A output (2500W) from 85-264 Vac. Steel case and fan cooling, operating -20 to +70 °C. With remote on/off, current sharing and SEMI F47 compliance.

Price and availability on request

Request a quote

Sent with the product details: Delta PMS-24V2K5W1BTD 24V 0-104.2A 2500W Panel Mount Power Supply, PMS Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage
  • Up to 2,500 Watt in 10.67" x 5" x 1.59" package
  • Peak power supported
  • Full power up to 50°C ambient
  • Option for constant current
  • 5 V / 2 A standby output
  • Active current sharing
  • Conformal coating
  • Class B Conducted and Radiated EMI
  • Remote On/Off and Power Good Signal
  • Support Ver 1.3 PMBus
  • Intelligent fan speed control
  • Optional USB/RS232/RS485 adapter for communication
  • Compliance to SEMI F47 @ 200Vac

Specifications

Product
SeriesPMS Series
MountingPanel mount
Output
Output Current0-104.2A
Output Voltage24V
Output Voltage Adjustment Range24-28 Vdc
Output Power2500W
Line Regulation±0.5% typ.
Load Regulation±1% typ.
PARD< 1% Vrated pk-pk @ rated load
Start-up Time2,000 ms with AC turn on
Hold-up Time16 ms @ 2000 W load, with 230 Vac input
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 115 & 230 Vac input with 0-50% or 50-100% load change / ± 10% @ 115 & 230 Vac input with 5-100% load change
Start-up with Capacitive Loads12,000 uF
Rise Time<50 ms
Peak Power3,200 W peak for 3 sec, @ 180~264 Vac
Input
Nominal Input Voltage100-240 Vac
Input Voltage Range85-264 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
Input Current16 A max.
Efficiency at 100% load93.4% typ. @ 230 Vac
Inrush Current40 A @ 264 Vac, cold start
Power Factor at 100% load0.95 @ 115 V / 50 Hz, 230 V / 50 Hz
Leakage Current< 0.3 mA @ 240Vac
Power Dissipation0.75 W typ. @ remote off status
Mechanical
Case Chassis / CoverSGCC
Cooling SystemForce Cooling
Input TerminalM3.5 x 3 Pins, CN1 / AC Input
Output TerminalM6 x 2 Pins, CN101 / DC Output
Unit Weight1.95 kg (4.30 lb)
Dimensions271 x 127 x 40.5 mm / 10.67” x 5.00” x 1.59”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 5 Hz to 500 Hz @ 2G;10 Min per cycle,60min for X, Y, Z direction
Operating Temperature-20°C to +70°C
Storage Temperature-40°C to +85°C
Power De-ratingTemperature: > 50°C de-rate power by 2.5% / °C / Input: 132-180 Vac, de-rate power by 0.83% / Vac from 2,500 W to 1,500 W @ 132 Vac / 100-110 Vac, de-rate power by 0.6% / Vac from 1,500 W to 1,350 W @ 100 Vac / 85-90 Vac, de-rate power by 2.8% / Vac from 1,350 W to 1,000 W @ 85 Vac
Operating Humidity5-95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
Operating Altitude0 to 5,000 Meters (0 to 16,400 ft)
Pollution Degree2
Acoustic Noise< 45dB @ 80% load @ 25°C (Tolerance: ±2dB)
Protections
OvervoltageMain output 145% max of rated normal voltage, Latch Mode / Standby 125% max of rated voltage, Latch Mode
Overload / OvercurrentMain output 130% max of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) / Standby 3.2A max with Hiccup Mode (Auto-Recovery)Main output 130% max of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) / Standby 3.2A max with Hiccup Mode (Non-Latching, Auto-Recovery)
Over TemperatureAuto-Recovery
Short CircuitHiccup Mode to Main output / Standby (Non-Latching, Auto-Recovery when the fault is removed)
Protection Against ShockClass I with Protection Earth connection
Reliability
MTBF500K hrs based on Telcordia SR-332 (@ 230 Vac, 100% Load, 35°C)
Expected Cap Life Time5 years, (@ 230 Vac, 100% load @ 25°C)
Safety
Electrical SafetyTUV Bauart: EN 62368-1 / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1 / CQC: GB 4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 1.5 KVac
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
EMC
Emission(CE & RE) / EN 55032, KS C 9832, Comply to FCC Title 47: Class B
Harmonic Current EmissionsIEC/EN 61000-3-2 Meet Class A limit
Voltage Fluctuation and FlickerEN 61000-3-3

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.