Delta PMR-4V320WDBA 4.2V 60A 252W Panel Mount Power Supply, PMR Series
- Brand
- Delta
- Model number
- PMR-4V320WDBA
PMR panel mount power supply with 4.2V 60A output (252W) from 88-264Vac. Aluminium case and convection cooling, operating -20 to +70 °C. With a DC OK signal and active PFC.
Price and availability on request
Key features
- Universal AC input voltage
- Full corrosion resistant aluminium case and chassis
- Built-in active PFC and conforms to harmonic current IEC/EN 61000-3-2, Class A and Class D
- Low profile design for 1U installation
- High reliability with fanless design
- Built-in DC OK relay contact and redundancy operation (PMR-4V320WDBA and PMR-4V320WDCA)
Specifications
| Series | PMR Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 60A |
|---|---|
| Output Voltage | 4.2V |
| Output Power | 252W |
| Line Regulation | ± 0.5% typ. (@ 115Vac & 230Vac, 100% load) |
| Load Regulation | ± 1.0% typ. (@ 115Vac & 230Vac, 0-100% load) / For PMR-4V320WDAA and PMR-4V320WDGA |
| PARD | < 150mVpp @ 25°C / < 300mVpp @ -20°C |
| Start-up Time | 3000ms typ. @ 115Vac / 1500ms typ. @ 230Vac (100% load) |
| Hold-up Time | 8ms typ. @ 115Vac & 230Vac |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 1500mVpp @ 10-50% load and 50-100% load |
| Start-up with Capacitive Loads | 8,000μF Max |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 88-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | < 4.50A@115Vac, < 2.50A @ 230Vac |
| Efficiency at 100% load | 84.5% typ. @ 115Vac, 86.5% typ. @ 230Vac |
| Inrush Current | < 20A @ 115Vac, < 40A @ 230Vac |
| Power Factor at 100% load | 0.98 typ. @ 115Vac, 0.95 typ. @ 230Vac |
| Leakage Current | < 1mA @ 240Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.86 kg (1.90 lb) |
| Dimensions | 215 x 115 x 30 mm / 8.46” x 4.53” x 1.18” |
| Operating Temperature | -20°C to +70°C |
|---|---|
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 40°C de-rate power by 1% / °C, > 50°C de-rate power by 1.5% / °C / < 110Vac de-rate power by 1% / 1V |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 shocks for each 3 directions |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction |
| Overvoltage | 5.00-6.00V, Hiccup Mode, Non-Latching / (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | 105-150%, Hiccup Mode, Non-Latching / (Auto-Recovery) |
| Over Temperature | Hiccup Mode, Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery) |
| Protection Against Shock | Class I with PE connection |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 |
|---|
| CE | In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC |
|---|
| Emission | CISPR 22, EN 55022, FCC Title 47: Class B |
|---|---|
| Immunity | EN 55024 |
| Harmonic Current Emissions | IEC/EN 61000-3-2, Class A and Class D |
| Voltage Fluctuation and Flicker | IEC/EN 61000-3-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.