Delta PMR-36V150W1AT 36V 4.3A 150W Panel Mount Power Supply, PMR Series
- Brand
- Delta
- Model number
- PMR-36V150W1AT
PMR panel mount power supply with 36V 4.3A output (150W) from 90-264 Vac or 127-375 Vdc. Aluminium and steel case and convection cooling, operating -40 to +70 °C. With active PFC and household appliance approvals.
Price and availability on request
Key features
- Universal AC input voltage
- Built-in active PFC and conforms to harmonic current IEC/EN 61000-3-2, Class A and Class D
- No load power consumption < 0.5 W
- Low profile design: 30 mm height
- Household appliance approvals according to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
- Wide operating temp -40°C ~70°C
Specifications
| Series | PMR Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 4.3A |
|---|---|
| Output Voltage | 36V |
| Output Voltage Adjustment Range | 32.4-39.6 Vdc |
| Output Power | 150W |
| Line Regulation | ± 0.5% typ. @ 115 Vac & 230 Vac |
| Load Regulation | ±0.5% typ. |
| PARD | < 150 mVpp @ 0°C to 70°C / 450 mVpp typ. @ -30°C to 0°C |
| Start-up Time | 500 ms typ. @ 115 Vac & 230 Vac |
| Hold-up Time | 30 ms typ. @ 115 Vac & 230 Vac |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 & 230 Vac input, 10-100% load / (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) |
| Start-up with Capacitive Loads | 6,000 µF Max |
| Max. Power | 154.8 W |
| Rise Time | 30 ms typ. @ 115 Vac & 230 Vac |
| Nominal Input Voltage | 100-240 Vac |
|---|---|
| Input Voltage Range | 90-264 Vac |
| Nominal Input Frequency | 50-60 Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 127-375 Vdc |
| Input Current | 1.5 A typ. @ 115 Vac / 0.8 A typ. @ 230 Vac |
| Input Power (Standby Mode) | 0.5 W max. @ 230 Vac |
| Efficiency at 100% load | 93.0% typ. @ 230 Vac |
| Inrush Current | 45 A typ. @ 230 Vac |
| Power Factor at 100% load | > 0.96 @ 115 Vac / > 0.93 @ 230 Vac |
| Leakage Current | < 0.5 mA @ 240 Vac |
| Case Chassis / Cover | Aluminum / SGCC |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Wire | AWG 18-12 |
| Terminal | M3.5 x 7 Pins (Rated 300 V / 20 A) |
| Unit Weight | 0.35 kg (0.77 lb) |
| Dimensions | 129 x 97 x 30 mm / 5.08” x 3.82” x 1.18” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2G;10Min per cycle,60min for X,Y,Z direction |
|---|---|
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2% / °C / < 100Vac de-rate power by 1% / V (90% load @ 90 Vac) |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Pollution Degree | 3 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
| Overvoltage | 39.6 V - 48.6 V / SELV Output / Latch Mode |
|---|---|
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching / (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with Protection Earth connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 / (I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
|---|---|
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1 / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60335-1, IEC/EN 61558-1/-2-16 / EAC: TP TC 004/2011 / BSMI: CNS 15598-1 / CCC: GB 4943.1 / BIS: IS 13252 (Part 1) |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 1.25 KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, KS C 9832, AS/NZS CISPR32 & Compliance to FCC Title 47, EN/BS EN 55014-1 , EN/BS 61000-6-3 , EN/BS EN 61000-6-4 : Class B |
|---|---|
| Immunity | EN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A & Class D |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.