PMR panel mount power supply with 12V 60A output (720W) from 90-264 Vac or 127-375 Vdc. Steel case and fan cooling, operating -40 to +70 °C. With active PFC, remote on/off and current sharing.
Price and availability on request
Key features
- Built-in active PFC and conforms to harmonic current IEC/EN 61000-3-2, Class A
- Active current sharing up to 4 units in parallel
- Built-in Remote ON/OFF and Remote Sense
- Compact 1U low-profile design
- Terminal block cover and conformal coating available
- Certified for industrial and household applications (IEC/EN 62368-1, 60335-1, 61558-1, 61558-2-16)
- Over voltage category III (OVC III)
- Wide operating temp -40°C ~70°C
Specifications
| Series | PMR Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 60A |
|---|---|
| Output Voltage | 12V |
| Output Voltage Adjustment Range | 10.8-13.2 Vdc |
| Output Power | 720W |
| Line Regulation | ± 0.5% typ. @ 115 Vac & 230 Vac |
| Load Regulation | ±1.0% typ. |
| PARD | < 150 mVpp @ 0°C to 70°C / 450 mVpp typ. @ -30°C to 0°C |
| Start-up Time | 500 ms typ. @ 115 Vac & 230 Vac |
| Hold-up Time | 20 ms typ. @ 115 Vac & 230 Vac |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 & 230 Vac input, 10-100% load / (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) |
| Start-up with Capacitive Loads | 8,000 µF Max |
| Max. Power | 720 W |
| Rise Time | 50 ms typ. @ 115 Vac & 230 Vac |
| Nominal Input Voltage | 100-240 Vac |
|---|---|
| Input Voltage Range | 90-264 Vac |
| Nominal Input Frequency | 50-60 Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 127-375 Vdc |
| Input Current | 7.5 A typ. @ 115 Vac, 3.5 A typ. @ 230 Vac |
| Input Power (Standby Mode) | 1.5 W typ. @ 230 Vac |
| Efficiency at 100% load | 92.0% typ. @ 230 Vac |
| Inrush Current | 45 A typ. @ 230 Vac |
| Power Factor at 100% load | > 0.96 @ 115 Vac & 230 Vac |
| Leakage Current | < 0.15 mA typ. @ 240 Vac, measured at 264 Vac / 50 Hz |
| Case Chassis / Cover | SGCC / SGCC |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Force Cooling |
| Input Terminal | M3.5 x 9 Pins (Rated 300 V / 20 A) |
| Output Terminal | M3.5 x 9 Pins (Rated 300 V / 20 A) |
| Signal Terminal | CN400 / Signal Connector: CVILUX CP3506P1H00-NH / Mating connector: CVILUX CP3506S0010 or equivalent |
| Wire | AWG 14-10 |
| Unit Weight | 1.45 kg (3.20 lb) |
| Dimensions | 225 x 124 x 41 mm / 8.86” x 4.88” x 1.61” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2G ; 10 min per cycle, 60 min for each axis (X,Y,Z) |
|---|---|
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2% / °C / < 100Vac de-rate power by 1% / V / (90% load @ 90 Vac) |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) |
| Pollution Degree | 3 |
| Over Voltage Category | II (Meet EN 62477-1 OVC III with 2000 meters altitude) |
| Overvoltage | 13.2 V - 16.8 V / SELV Output / Latch Mode |
|---|---|
| Overload / Overcurrent | 150% of rated load current, Auto-recovery / Continuous current limit Mode (Vo > 80%) |
| Over Temperature | Auto-recovery |
| Short Circuit | Auto-Recovery, Non-Latching / (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with Protection Earth connection |
| Internal Fuse | T20 A / 420 V |
| MTBF | > 700,000 hrs as per Telcordia SR-332 / (I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
|---|---|
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1 / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60335-1, IEC/EN 61558-1/-2-16 / EAC: TP TC 004/2011 / BSMI: CNS 15598-1 / CCC: GB4943.1-2022 / BIS: IS 13252 (Part 1) |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 1.25 KVac |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, KS C 9832, AS/NZS CISPR32 & Compliance to FCC Title 47, EN/BS EN 55014-1 , EN/BS 61000-6-3 , EN/BS EN 61000-6-4 : Class B |
|---|---|
| Immunity | EN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.