PMH panel mount power supply with 24V 4.16A output (100W) from 85-264Vac or 120-375Vdc. Aluminium case and convection cooling, operating -30 to +70 °C. With household appliance approvals.
Price and availability on request
Key features
- Household appliance approvals IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
- Universal AC input voltage
- Full power from -20°C to +50°C operation @ 5000m or 16400 ft. altitude
- Full corrosion resistant aluminium casing
- No load power consumption < 0.5W
- High MTBF > 700,000 hrs as per Telcordia SR-332
- Versatile connector options available: IP20, Front Face and Harness connectors
- Certified according to IEC/EN/UL 62368-1
Specifications
| Series | PMH Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 4.16A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 22-28Vdc |
| Output Power | 100W |
| Line Regulation | < 0.5% (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 85-264Vac input, 0-100% load) |
| PARD | < 100mVpp |
| Start-up Time | < 1300ms @ 100Vac (100% load) / < 750ms @ 240Vac (100% load) |
| Hold-up Time | > 15ms @ 115Vac, > 100ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1KHz) |
| Start-up with Capacitive Loads | 8,000μF Max |
| Rise Time | < 20ms @ nominal input (@ -20°C to 70°C) / < 30ms @ nominal input (@ < -20°C to -30°C) |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | 125-250Vdc |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 1.90A @ 115Vac, < 1.10A @ 230Vac |
| Efficiency at 100% load | > 87.0% @ 115Vac, > 89.0% @ 230Vac |
| Inrush Current | (Cold Start) / < 50A @ 115Vac, < 100A @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Power Dissipation | No Load: < 0.5W @ 115Vac & 230Vac / 100% Load: 15.0W typ. @ 115Vac & 12.2W typ. @ 230Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Unit Weight | 0.43 kg (0.95 lb) |
| Dimensions | 158 x 97 x 38 mm / 6.22” x 3.82” x 1.50” |
| Operating Temperature | -30°C to +70°C |
|---|---|
| Storage Temperature | -30°C to +85°C |
| Power De-rating | -20°C to -30°C de-rate power by 2.0% / °C > 50°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,1 times per direction, 2 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 3 |
| Bump Test (Operating) | IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000 times per direction, 6000 times in total |
| Over Voltage Category | II |
| Overvoltage | 28.8-35.2V range, Hiccup Mode, Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | > 120% of rated load current, Hiccup Mode, Non-Latching (Auto recovery) |
| Over Temperature | < 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed). |
| Degree of Protection | IP20 (PMH-24V100WC☐U and PMH-24V100WC☐J) |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 / I/P: 115Vac, O/P: 100% load, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) |
| Electrical Safety | SIQ Bauart: EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16, EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16, IEC 62368-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.2KVac / Input to Ground: 1.5KVac / / Output to Ground: / Output non-isolated to PE (common pins connect to PE) (PMH-24V100WC☐A, PMH-24V100WC☐J, PMH-24V100WC☐L, PMH-24V100WC☐H) / 1.5KVdc (Output isolated to PE) (PMH-24V100WC☐S, PMH-24V100WC☐U, PMH-24V100WC☐V, PMH-24V100WC☐T) |
| Safety Entry Low Voltage | Output non-isolated to PE: PELV (EN 60335), SELV (EN 60950) / Output isolated to PE: SELV (EN 60335), SELV (EN 60950) |
| Emission | (CE & RE) / EN 55011, EN 55032, CISPR 32, FCC Title 47: Class B, EN 55014-1, EN 61000-6-3 |
|---|---|
| Immunity | EN 55024, EN 61000-6-2, EN 55014-2 |
| Harmonic Current Emissions | IEC/EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN 61000-3-3 |
| Tags | Pollution Degree 3 |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.