Delta PMH-12V100WCLS 12V 8.5A 102W Panel Mount Power Supply, PMH Series

Brand
Delta
Model number
PMH-12V100WCLS

PMH panel mount power supply with 12V 8.5A output (102W) from 85-264Vac or 120-375Vdc. Aluminium case and convection cooling, operating -30 to +70 °C. With household appliance approvals.

Price and availability on request

Request a quote

Sent with the product details: Delta PMH-12V100WCLS 12V 8.5A 102W Panel Mount Power Supply, PMH Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Household appliance approvals for pollution degree 3 to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
  • Universal AC input voltage
  • Withstand line input voltage surge 300Vac up to 7 seconds
  • Full power from -25°C to +50°C operation @ 5000m or 16400 ft. altitude
  • Full corrosion resistant aluminium casing
  • No load power consumption < 0.3W @ 115Vac
  • Low earth leakage current < 0.75mA
  • Versatile connector options available: IP20, Front Face and Harness connectors
  • Certified according to IEC/EN/UL 62368-1

Specifications

Product
SeriesPMH Series
MountingPanel mount
Output
Output Current8.5A
Output Voltage12V
Output Voltage Adjustment Range12-14Vdc
Output Power102W
Line Regulation< 1.0% (@ 100-264Vac input, 100% load)
Load Regulation< 2.0% (@ 100-264Vac input, 0-100% load)
PARD< 120mVpp
Start-up Time< 2500ms @ 115Vac (100% load), / < 1500ms @ 230Vac (100% load)
Hold-up Time> 5ms @ 115Vac, > 50ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 100-264Vac input, 0-50%, 0-100%, 50-100% load / (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1kHz)
Start-up with Capacitive Loads3,000μF Max
Rise Time< 100ms @ nominal input (100% load)
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range120-375Vdc
Input Current< 1.90A @ 115Vac, < 1.20A @ 230Vac
Efficiency at 100% load> 83% @115Vac, > 85% @ 230Vac
Inrush Current(Cold Start) / < 30A @ 115Vac, < 60A @ 230Vac
Leakage Current< 0.75mA @ 240Vac
Power DissipationNo Load: < 0.3W @ 115Vac, < 0.5W @ 230Vac / 100% Load: < 19.0W @ 115Vac, < 17.0W @ 230Vac
Mechanical
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Noise Sound Pressure Level (SPL)< 25dBA
Unit Weight0.31 kg (0.68 lb)
Dimensions129 x 97 x 30 mm / 5.08” x 3.82” x 1.18”
Environment
Operating Temperature-30°C to +70°C
Storage Temperature-40°C to +85°C
Power De-ratingTemperature: / 120Vac / < -25°C de-rate power by 5.0% / °C / 120Vac and 240Vac / > 50°C de-rate power by 2.0% / °C / Input Voltage: / < 100Vac de-rate power by 1.33%/°C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree3
Over Voltage CategoryII
Protections
Overvoltage< 17.5V, SELV Output, Latch mode
Overload / Overcurrent115~150% of rated load current, Hiccup mode, Non-Latching (Auto recovery)
Over Temperature< 75°C Surrounding Air Temperature @ 100% load, Latch mode
Short CircuitHiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
Degree of ProtectionIP20 (PMH-12V100WCLU)
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF> 700,000 hrs. as per Telcordia SR-332 / I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety
Electrical SafetySIQ Bauart: EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16, EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16, IEC 62368-1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0KVac / Input to Ground: 2.0KVac / Output to Ground: 1.0KVdc
Safety Entry Low VoltageSELV (EN 60950-1)
EMC
Emission(CE & RE) / EN 55011, EN 55032, CISPR 32, FCC Title 47: Class B, EN 61000-6-3
ImmunityEN 55024, EN 61000-6-2
Harmonic Current EmissionsIEC/EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN 61000-3-3
Component Power Supply for General UseEN 61204-3

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.