Delta PMF-24V320WCGB 24V 13.33A 320W Panel Mount Power Supply, PMF Series

Brand
Delta
Model number
PMF-24V320WCGB

PMF panel mount power supply with 24V 13.33A output (320W) from 85-264Vac. Aluminium case and fan cooling, operating -10 to +70 °C. With active PFC.

Price and availability on request

Request a quote

Sent with the product details: Delta PMF-24V320WCGB 24V 13.33A 320W Panel Mount Power Supply, PMF Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage
  • Built-in active PFC and fan speed control
  • Full corrosion resistant aluminium chassis
  • Conforms to harmonic current IEC/EN/BS EN 61000-3-2, Class A and Class D
  • Cold start -20°C at 100% load (320W)
  • Remote ON/OFF is available as an option

Specifications

Product
SeriesPMF Series
MountingPanel mount
Output
Output Current13.33A
Output Voltage24V
Output Voltage Adjustment Range21.6-26.4Vdc
Output Power320W
Line Regulation± 0.2% typ. (@ 115Vac & 230Vac)
Load Regulation± 1.0% typ. (@ 115Vac & 230Vac)
PARD< 150mVpp @ 25°C / < 300mVpp @ -10°C
Start-up Time2500ms typ. @ 115Vac, / 800ms typ. @ 230Vac (100% load)
Hold-up Time20ms typ. @ 115Vac & 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% (2.4V pk-pk) @ 115Vac & 230Vac (0-100% load)
Start-up with Capacitive Loads8,000µF Max
Remote ON/OFFCN102 / Output ON: 5-12.5 V / Output OFF: 0-0.5 V
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Input Frequency Range47-63Hz
Input Current< 5.00A @ 115Vac, / < 2.50A @ 230Vac
Efficiency at 100% load87.0% typ. @ 230Vac
Power Factor at 100% load0.98 typ. @ 115Vac, / 0.95 typ. @ 230Vac
Leakage Current< 1mA @ 240Vac
Mechanical
Case Chassis / CoverAluminium
Cooling SystemForced Cooling
Unit Weight0.84 kg (1.85 lb)
Dimensions215 x 115 x 50 mm / 8.46” x 4.53” x 1.97”
Environment
Operating Temperature-10°C to +70°C (Cold start at -20°C)
Storage Temperature-25°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% / °C / < 100Vac de-rate power by 1.33% / 1V
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
Protections
Overvoltage27.6-32.4V, Latch Mode (AC power is recycled)
Overload / Overcurrent105-150%, Hiccup Mode, Non-Latching (Auto-Recovery)
Over TemperatureHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE(Primary Earth) connection
Reliability
MTBF> 700,000 hrs. as per Telcordia SR-332 / I/P: 100Vac, O/P: 100% load, Ta: 35°C
Safety
Electrical SafetyTUV Bauart:EN 60950-1, EN 62368-1 / UL/cUL recognized:UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) / UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme:IEC 60950-1, IEC 62368-1 / CCC: GB4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 0.5 KVac
Safety Entry Low VoltageSELV (EN 60950-1)
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 / and Electrical Equipment (Safety) Regulations 2016
EMC
EmissionCISPR 22, EN/BS EN 55022, FCC Title 47: Class B
ImmunityEN/BS EN 55024
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A and Class D
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.