Delta PMC-24V600W1RW 24V 25A 600W Panel Mount Power Supply, PMC Series

Brand
Delta
Model number
PMC-24V600W1RW

PMC panel mount power supply with 24V 25A output (600W) from 85-264Vac. Steel case and fan cooling, operating -20 to +70 °C. With a constant-current mode and conformal-coated boards.

Price and availability on request

Request a quote

Sent with the product details: Delta PMC-24V600W1RW 24V 25A 600W Panel Mount Power Supply, PMC Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input range
  • Active PFC with high PF value
  • Meet Surge Immunity IEC 61000-4-5, Level 4 (CM: 4kV, DM: 2kV)
  • Wide operating temperature range -20°C to 70°C
  • Compact Size
  • Conformal coating on PCBA to protect against chemical and dust pollutants
  • Built-in constant current circuit for reactive loads
  • Design compliance with Japan PSE (DENAN)

Specifications

Product
SeriesPMC Series
MountingPanel mount
Output
Output Current25A
Output Voltage24V
Output Voltage Adjustment Range21.6-27.6Vdc
Output Power600W
Line Regulation± 0.4% typ. (@ 115 & 240Vac input, 100% load)
Load Regulation± 0.5% typ. (@115 & 240Vac input, 100% load)
PARD< 150mVpp @ 0°C to 70°C, / 180mVpp typ. @ -20°C to 0°C
Start-up Time500ms typ. @ 230Vac (100% load)
Hold-up Time20ms typ. @ 115Vac & 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 50-100% load
Start-up with Capacitive Loads10,000μF Max
Rise Time< 50ms @ 115Vac & 230Vac (100% load)
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current6A typ. @ 115Vac, 3A typ. @ 230Vac
Efficiency at 100% load90.0% typ. @ 115Vac, 92.0% typ. @ 230Vac
Inrush Current40 A typ. @ 230 Vac
Power Factor at 100% load0.99 typ. @ 100Vac, 0.97 typ. @ 200Vac
Leakage Current< 0.75mA @ 240Vac
Mechanical
Case Chassis / CoverSGCC
Cooling SystemBuilt-in Fan
Input TerminalM3.5 x 3 Pins (Rated 300Vac/20A)
Output TerminalM4 x 4 Pins (Rated 300Vac/25A)
Signal TerminalSignal Connector: JST S8B-PHDSS(LF)(SN) / Mating connector: JST PHDR-08VS or equivalent
Noise Sound Pressure Level (SPL)< 60dBA
Unit Weight1.4 kg (3.09 lb)
Dimensions190 x 120 x 61 mm / 7.48” x 4.72” x 2.40”
Environment
Vibration (Operating)IEC60068‐2‐6, Sine Wave: 10Hz to 55Hz @19.6m/s2(2G peak); / 10min per cycle, 60min per axis for all X,Y,Z direction
Shock Test (Operating)IEC60068‐2‐27, Half Sine Wave: 10G for a duration of 11ms, 3 shocks for each 3 directions
Operating Temperature-20°C to +70°C
Storage Temperature-30°C to +75°C
Power De-rating> 50°C de-rate power by 2.5% / °C / < 110Vac de-rate power by 0.8% / 1V
Operating Humidity20-95% RH
Shock Test (Non-Operating)IEC60068‐2‐27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration (Non-Operating)IEC60068‐2‐6, Random: 5Hz to 500Hz (2.09Grms); / 20min per axis for all X,Y,Z direction
Operating Altitude5,000 Meters
Pollution Degree2
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Protections
Overvoltage27.6-33.6V, SELV Output, Latch-off Mode
Overload / Overcurrent105~160%; Constant current limit with automatic recovery
Over TemperatureLatch-off Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with PE connection
Reliability
MTBF> 700,000 hrs as per Telcordia SR-332 / I/P: 115Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time10 years (115 Vac, 50% load @ 40°C)
Safety
Electrical SafetyTUV Bauart: EN 62368-1 / UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 / CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1 / KC: K 60950-1 / CCC: 4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0KVac / Input to Ground: 1.8KVac / Output to Ground: 0.5KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
EMC
EmissionCISPR 32, EN/BS EN 55032 / Compliance to FCC Title 47, VCCI, EN 55011 : Class B
ImmunityEN/BS EN 55035, KN35 / Compliance to EN 61000-6-2
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2 Class A
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
ESD ImmunityIEC 61000-4-2: Level 4 Criteria A / Air Discharge: 15kV / Contact Discharge: 8kV
EFTIEC 61000-4-4: Level 3 Criteria A / 2kV
SurgeIEC 61000-4-5: Level 4 Criteria A / Common Mode: 4kV / Differential Mode: 2kV
Conducted ImmunityIEC 61000-4-6 : Level 3 Criteria A / 150kHz-80MHz, 10Vrms
Magnetic FieldIEC 61000-4-8 : Level 4 Criteria A / 30A/Meter
Voltage DipsIEC 61000-4-11 : / 0% residual; 1 cycle, Criteria B / 40% residual; 10 cycle, Criteria C / 70% residual; 25 cycle, Criteria C