Delta PMC-24V100W1AA 24V 4.17A 100W Panel Mount Power Supply, PMC Series
- Brand
- Delta
- Model number
- PMC-24V100W1AA
PMC panel mount power supply with 24V 4.17A output (100W) from 85-264Vac or 125-375Vdc. Aluminium case and convection cooling, operating -10 to +70 °C.
Price and availability on request
Key features
- Universal AC input range
- Power will not de-rate for the entire input voltage range
- Full corrosion resistant aluminium casing
- High MTBF > 700,000 hrs as per Telcordia SR-332
- Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1
- Also available: IP20 and Front Face connectors
Specifications
| Series | PMC Series |
|---|---|
| Mounting | Panel mount |
| Output Current | 4.17A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 22-28Vdc |
| Output Power | 100W |
| Line Regulation | < 0.5% typ. (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1% typ. (@ 85-264Vac input, 0-100% load) |
| PARD | < 150mVpp |
| Start-up Time | < 1000ms @ nominal input (100% load) |
| Hold-up Time | > 15ms @ 115Vac, / > 90ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 100Hz) |
| Start-up with Capacitive Loads | 8,000µF Max |
| Rise Time | < 30ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | 125-250Vdc |
| DC Input Voltage Range | 125-375Vdc |
| Input Current | < 2.0A @ 115Vac, < 1.1A @ 230Vac |
| Efficiency at 100% load | > 86% @ 115Vac & 230Vac |
| Inrush Current | < 50A @ 115Vac, < 100A @ 230Vac |
| Power Factor at 100% load | Conform to EN61000-3-2, Class A |
| Leakage Current | < 1mA @ 240Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Unit Weight | 0.41 kg (0.90 lb) |
| Dimensions | 158 x 97 x 38 mm / 6.22” x 3.82” x 1.50” |
| Operating Temperature | -10°C to +70°C |
|---|---|
| Storage Temperature | -25°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2.5% /°C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC60068-2-27, 30G (300m/S²) for a duration of 18ms 3 times per direction, 18 times in total |
| Vibration (Non-Operating) | IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction |
| Operating Altitude | 3,000 Meters (9,840 ft.) |
| Pollution Degree | 2 |
| Overvoltage | < 32V ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | > 120% of rated load current, Hiccup Mode, Non-Latching (Auto recovery) |
| Over Temperature | < 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-recovery). |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed). |
| Degree of Protection | IP20 (PMC-24V100W1AJ) |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | > 700,000 hrs, as per per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) |
| Electrical Safety | SIQ Bauart : EN 62368-1 / UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CCC : GB4943.1 / CB scheme : IEC 60950-1, IEC 62368-1 KC : KN32, KN35 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 3.0 KVac / Input to Ground: 1.5 KVac / Output to Ground: 0.5 KVac |
| Safety Entry Low Voltage | SELV (IEC 60950-1) |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and / The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| Emission | Generic Standards: CISPR 32, EN/BS EN 55032, KN 32, FCC Title 47: Class B, GB 9254.1 |
|---|---|
| Immunity | Generic Standard: EN/BS EN 55024, KN 35 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A; GB 17625.1 |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.