Delta PMC-24V100W1AA 24V 4.17A 100W Panel Mount Power Supply, PMC Series

Brand
Delta
Model number
PMC-24V100W1AA

PMC panel mount power supply with 24V 4.17A output (100W) from 85-264Vac or 125-375Vdc. Aluminium case and convection cooling, operating -10 to +70 °C.

Price and availability on request

Request a quote

Sent with the product details: Delta PMC-24V100W1AA 24V 4.17A 100W Panel Mount Power Supply, PMC Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input range
  • Power will not de-rate for the entire input voltage range
  • Full corrosion resistant aluminium casing
  • High MTBF > 700,000 hrs as per Telcordia SR-332
  • Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1
  • Also available: IP20 and Front Face connectors

Specifications

Product
SeriesPMC Series
MountingPanel mount
Output
Output Current4.17A
Output Voltage24V
Output Voltage Adjustment Range22-28Vdc
Output Power100W
Line Regulation< 0.5% typ. (@ 85-264Vac input, 100% load)
Load Regulation< 1% typ. (@ 85-264Vac input, 0-100% load)
PARD< 150mVpp
Start-up Time< 1000ms @ nominal input (100% load)
Hold-up Time> 15ms @ 115Vac, / > 90ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 100Hz)
Start-up with Capacitive Loads8,000µF Max
Rise Time< 30ms @ nominal input (100% load)
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Nominal DC Input Voltage125-250Vdc
DC Input Voltage Range125-375Vdc
Input Current< 2.0A @ 115Vac, < 1.1A @ 230Vac
Efficiency at 100% load> 86% @ 115Vac & 230Vac
Inrush Current< 50A @ 115Vac, < 100A @ 230Vac
Power Factor at 100% loadConform to EN61000-3-2, Class A
Leakage Current< 1mA @ 240Vac
Mechanical
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Noise Sound Pressure Level (SPL)< 40dBA
Unit Weight0.41 kg (0.90 lb)
Dimensions158 x 97 x 38 mm / 6.22” x 3.82” x 1.50”
Environment
Operating Temperature-10°C to +70°C
Storage Temperature-25°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% /°C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC60068-2-27, 30G (300m/S²) for a duration of 18ms 3 times per direction, 18 times in total
Vibration (Non-Operating)IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction
Operating Altitude3,000 Meters (9,840 ft.)
Pollution Degree2
Protections
Overvoltage< 32V ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent> 120% of rated load current, Hiccup Mode, Non-Latching (Auto recovery)
Over Temperature< 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-recovery).
Short CircuitHiccup Mode, Non-Latching (Auto-recovery when the fault is removed).
Degree of ProtectionIP20 (PMC-24V100W1AJ)
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF> 700,000 hrs, as per per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety
Electrical SafetySIQ Bauart : EN 62368-1 / UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CCC : GB4943.1 / CB scheme : IEC 60950-1, IEC 62368-1 KC : KN32, KN35
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0 KVac / Input to Ground: 1.5 KVac / Output to Ground: 0.5 KVac
Safety Entry Low VoltageSELV (IEC 60950-1)
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and / The Electromagnetic Compatibility Regulations 2016 No. 1091
EMC
EmissionGeneric Standards: CISPR 32, EN/BS EN 55032, KN 32, FCC Title 47: Class B, GB 9254.1
ImmunityGeneric Standard: EN/BS EN 55024, KN 35
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A; GB 17625.1
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.