Delta mPSU-W1AC-24DC-1000 24V 41A 1000W Enclosed Power Supply, mPSU Series
- Brand
- Delta
- Model number
- mPSU-W1AC-24DC-1000
mPSU enclosed power supply with 24V 41A output (1000W) from 90-264Vac or 127-418V. Metal case and fan cooling, operating -20 to +70 °C. With power boost, medical safety design and battery backup.
Price and availability on request
Key features
- Scalable modular power platform / 150–1500 W modules in 1U design combine in stand-alone, series, parallel and mixed configurations to scale power, voltage and system architecture.
- Medical-Grade Reliability / Designed according to IEC 60601-1 & IEC 62368-1 requirements with low leakage current, supporting demanding medical and industrial applications requiring high safety standards.
- Digital configuration and monitoring / Adjust and monitor voltage, current limits, fan control and other system parameters via communication interfaces (CANopen, Modbus).
- User-friendly plug-and-play connectivity / Plug-and-play connector design eliminates complex wiring, reduces installation errors, and removes the need for specialized personnel, enabling faster commissioning and easier servicing.
- Flexible system configuration / Up to 16 modules in 4×4 rack configuration possible.
- Configurable battery charging / Supports CC-CV charging profiles for lithium-ion batteries and configurable battery applications.
- 10 sec. recurring 20% Power Boost / Provides additional power for 10 seconds with 50 seconds recovery time for dynamic load requirements.
- Standardized dimensions and easy service access / 1U design with front-access connections.
- Low acoustic noise / Optimized fan control and intelligent load-dependent cooling ensure exceptionally quiet operation while maintaining reliable thermal performance.
- Intelligent thermal management / Standard and customized fan speed control optimizes cooling performance according to system load.
- Outstanding EMC performance / Exceeds EMC Class B requirements by 6 dB across multiple operating points throughout the full power range, simplifying system integration and compliance.
Specifications
| Series | mPSU Series |
|---|---|
| Mounting | Enclosed |
| Output Current | 41A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Range | 19.2-28.8Vdc |
| Output Power | 1000W |
| Line Regulation | ± 0.5% |
| Load Regulation | ± 2.5% |
| PARD | < 200mVpp |
| Start-up Time | < 1500 ms |
| Hold-up Time | > 20ms @Poutnom, Voutnom |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | +2 / -3 peak @25% → 75% → 25% Iout |
| Start-up with Capacitive Loads | 50mF |
| Remote ON/OFF | Yes |
| Max. Power | 1200W |
| Power Boost Duration | 10s |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | 141-380Vdc |
| DC Input Voltage Range | 127-418V |
| Input Current | 12.5 A typ. @ 90 Vac |
| Input Power (Standby Mode) | off by INH_E, 1.2W max. off by INH_BUS or INH_T, 6.0W max. |
| Efficiency at 100% load | 93.0% typ @ 240Vac |
| Inrush Current | < 20Apeak @ 240Vac |
| Power Factor at 100% load | 0.99 |
| Efficiency @ 10% load | 80% typ. @ 230 Vac |
| Case Chassis / Cover | Metal |
|---|---|
| Indicator | Green LED: Power Good / Green LED: RXD Communciation |
| Cooling System | Forced dual Fan cooled / Variable speed control |
| Input Terminal | Wago X-Com PSU: 769-663/004-000 / Counterpart/Plug: 769-103 3 Pins Rated 500 V / 32 A |
| Output Terminal | Wago MCS Maxi6: PSU: 831-3622 / Counterpart/Plug: 831-3102 2 Pins Rated 500 V / 41 A |
| Signal Terminal | IX Industial Key B 10 Pins Rated 60 V / 1.5 A |
| Noise Sound Pressure Level (SPL) | <25 dBA @0% Fan PWM / < 68 dBA @100% Fan PWM |
| Unit Weight | 1.9 (2.20 lb) |
| Dimensions | 283 x 127 x 40.6 mm / 11.14” x 5.00” x 1.60” |
| Vibration (Operating) | IEC 60068-2-6 2.09 Grms, 5 - 500 Hz, 20 minutes per side (3 planes) |
|---|---|
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | operating, 50% Pout_nom, full performance @+70°C |
| Operating Humidity | 20 to 90% |
| Shock Test (Non-Operating) | IEC 60068-2-27 50 G, 11ms, 3 shocks in each direction |
| Operating Altitude | 3,000 Meters |
| Pollution Degree | II |
| Over Voltage Category | II |
| Overvoltage | < 32V, Latch mode |
|---|---|
| Overload / Overcurrent | 120% of rated load current |
| Over Temperature | Auto-recovery |
| Short Circuit | Output shutdown ,Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Reverse Polarity Protection | Yes |
| Internal Fuse | Dual 16A fuses |
| MTBF | With IEC 61709 > 700kh (Tamb. = 25°C), > 450k h (Tamb. = 40°C) |
|---|---|
| Expected Cap Life Time | 10 years (typ. input voltage, 80%load @ 40°C) |
| Electrical Safety | -IEC 62368-1:2018 / -UL 62368-1 ed.3 / -CSA C22.2 NO. 62368-1:19 / -CCC GB4943.1 / -BIS IS 13252(Part 1):2010 |
|---|---|
| CE | Yes |
| Medical Safety | -IEC 60601-1 / -ANSI/AAMI ES60601-1 / -CAN/CSA C22.2 No. 60601-1:14 |
| Galvanic Isolation | input to output & PMI 4.0kVac / input to PE 1.5kVac |
| UKCA | Yes |
| BIS | Yes |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.