Delta IMA-S400-12-ZNPLY 12V 0-33.3A 400W Enclosed Power Supply, IMA Series
- Brand
- Delta
- Model number
- IMA-S400-12-ZNPLY
IMA enclosed power supply with 12V 0-33.3A output (400W) from 80-275Vac or 120-300Vdc. Convection cooling, operating -20 to +70 °C. With medical safety design and current sharing.
Price and availability on request
Key features
- Safety approval for Medical (IEC 60601-1-2), Industrial (IEC 62368) and IT
- Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc
- Wide adjustable output voltage range (+/- 20%)
- 5 Vdc standby output
- High efficiency: up to 94%
- Size: 4 x 6.96 x 1.6 in (1U design)
- Low acoustic noise level of less than 30 dB(A)
- Active current sharing
- 2 × MOPP
- PMBus™compatible for control, programming and monitoring
- 500,000 hour MTBF
- Optional conformal coating
Specifications
| Series | IMA Series |
|---|---|
| Mounting | Enclosed |
| Output Current | 0-33.3A |
|---|---|
| Output Voltage | 12V |
| Output Voltage Adjustment Range | 9.6-14.4Vdc |
| Output Power | 400W |
| PARD | < 1% peak to peak |
| Start-up Time | < 2.5 s (@ AC OFF to ON, max. load) / < 150 ms (@ REMOTE OFF to ON, max. load) |
| Hold-up Time | 20 msec nominal |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | < 5% |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 80-275Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-300Vdc |
| Input Current | 6A @ 80Vac / 3.8A @ 120Vdc |
| Efficiency at 100% load | 90% @ 115Vac / 92% @ 230Vac |
| Inrush Current | < 20A |
| Power Factor at 100% load | 0.9 (typical) |
| Cooling System | System airflow cooling/natural convection cooling |
|---|---|
| Unit Weight | 0.960 kg (2.12 lb) |
| Dimensions | 176.8 x 101.6 x 40.6 mm / 6.96” x 4.00” x 1.60” |
| Operating Temperature | -20°C to +70°C |
|---|---|
| Storage Temperature | -40°C to +85°C |
| Power De-rating | When AC input voltage is < 90 Vac, the output power will be reduced by 4 W per 1 V. |
| Operating Humidity | < 95% (non-condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27 compliant, 50 g, 11 msec, 3 shocks for each direction |
| Vibration (Non-Operating) | IEC 60068-2-6 compliant, 2.09 Grms, 5 Hz to 500 Hz, 20 minutes per side (3 planes) |
| Overvoltage | YES, latch mode / 15V to 17.5V |
|---|---|
| Overload / Overcurrent | YES, at 108% to 140% of nominal output current; auto recovery |
| Over Temperature | YES, auto recovery |
| Short Circuit | YES, auto recovery |
| MTBF | 500,000 hours (Telecordia SR-332, Issue 3, 25 °C, 90% confidence level) |
|---|
| Electrical Safety | IEC 62368-1 (2014) Edition 2 / UL 60950-1/CSA 22.2 No 60950-1, Edition 2 |
|---|---|
| Medical Safety | IEC 60601-1(2005), EN60601-1(2006) / ANSI/AAMI ES 60601-1(2005) / CAN/CSA C22.2 No. 60601-1 (2008) |
| Galvanic Isolation | Input to Output (Reinforced): 4000 Vac; 2 x MOPP / Input to Case (Basic): 1500 Vac; 1 x MOPP / Output to Case (Basic): 1500 Vac; 1 x MOPP |
| Emission | EN 55011, EN 55022 and FCC, Class B |
|---|---|
| Harmonic Current Emissions | EN 61000-3-2, Class A |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.