Delta IMA-S2000-24-YV 24V 83.3A 2000W Enclosed Power Supply, IMA Series

Brand
Delta
Model number
IMA-S2000-24-YV

IMA enclosed power supply with 24V 83.3A output (2000W) from 80 - 275 Vac or 120 - 300 Vdc. Fan cooling, operating -20 to +70 °C. With medical safety design and current sharing.

Price and availability on request

Request a quote

Sent with the product details: Delta IMA-S2000-24-YV 24V 83.3A 2000W Enclosed Power Supply, IMA Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Safety approval for Medical (IEC 60601-1-2 and 3rd+A1 edition CB report) TUV EN60601-1:2006
  • CAN/CSA-C22.2 NO.60601-1 + ANSI/AAMI, ES 60601-1, 3000m altidude, 100-240Vac only
  • Industrial (IEC 62368) and IT IEC60950-1 CB report, IEC62368-1 CB report, TUV EN62368-1, UL62368-1 and CAN/CSA C22.2 No. 62368-1
  • 3000 Watt peak power (up to 5s)
  • Standby power < 2 Watt
  • Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc
  • Wide adjustable output voltage range (+/- 20%)
  • Standby output 5 Vdc / 2 A
  • High efficiency: up to 94%
  • Size: 309.6 x 127 x 40.6 mm (12.2 x 5 x 1.6 in) (1U design)
  • Low acoustic noise level of less than 39 dB(A), variable speed fan control
  • Active current sharing
  • 2 × MOPP and BF appliances
  • PMBus™ compatible for control, programming and monitoring
  • 500,000 hour MTBF
  • Optional conformal coating
  • 3 years warranty

Specifications

Product
SeriesIMA Series
MountingEnclosed
Output
Output Current83.3A
Output Voltage24V
Output Voltage Range24Vdc
Output Voltage Adjustment Range19.2 V – 28.8 V
Output Power2000W
Hold-up Time20 ms
Start-up with Capacitive Loads10,000 μF
Residual Ripple/PARD (20MHz)TBD
Rise Time< 200 ms
Input
Nominal Input Voltage100 - 240 Vac
Input Voltage Range80 - 275 Vac
Nominal Input Frequency50 - 60 Hz
Input Frequency Range47-63Hz
DC Input Voltage Range120 - 300 Vdc
Input Current17.2 A @ 80 Vac / 12 A @ 120 Vdc
Inrush Current< 25 A
Power Factor at 100% load> 0.97 (typical)
Leakage CurrentAC Leakage current from Input to earth ground / AC Leakage current from Output to earth ground
Mechanical
IndicatorGreen LED
Cooling System2 fans with variable speed control
Input TerminalBlock M4 x 3 pins
Output TerminalBlock M5 x 2 pins
Signal TerminalConnector x 14 pins
Noise Sound Pressure Level (SPL)< 39 dB(A)
Unit Weight2 kg (4.41 lb)
Dimensions309.6 x 127 x 40.6 mm / 12.19” x 5.00” x 1.60”
Environment
Operating Temperature-20 °C to +70 °C (-4°F to +158 °F)
Storage Temperature-40 °C to +85 °C (-40 °F to +185 °F)
Power De-ratingWhen AC input voltage is < 110 Vac, the output power is reduced by 20 W per 1 V.
Shock Test (Non-Operating)IEC 60068-2-27 compliant, 50 g, 11 ms, 3 shocks for each direction
Vibration (Non-Operating)IEC 60068-2-6 compliant, 2.09 Grms, 5 - 500 Hz, 20 minutes per side (3 planes)
Operating Altitude5000 m (54kPa)
Pollution Degree2
Protections
OvervoltageYES, latch mode / 30 V to 35 V
Overload / Overcurrent3000 W for over 750 ms max / Standby 3.2 A max with Hiccup Mode (Non-Latching, Auto-Recovery)
Over TemperatureYES, auto recovery
Short CircuitYES, auto recovery
Reliability
MTBF500,000 hours
Expected Cap Life Time10 years
Safety
Safety CertificateIEC 62368 Edition 2: / IEC 62368-1 (2014) Edition 2 / 5000 m (16,400 ft) altitude, 120 V to 300 Vdc and 100 V to 240±10% Vac / / IEC/EN 60950-1, Edition 2 and all national deviations: / UL 60950-1/CSA 22.2 No 60950-1, Edition 2; UL 62368-1 / 5000 m (16,400 ft) altitude, 120 V to 300 Vdc and 100 V to 240 ±10% Vac (UL File E135494) / / IEC/EN 60601-1, Edition 3: / IEC 60601-1(2005), EN60601-1(2006) / ANSI/AAMI ES 60601-1(2005) / CAN/CSA C22.2 No. 60601-1 (2008); 3,000 m (9,800 ft) altitude, 100 V
EMC
EmissionEN 55032, EN 55032 and FCC, Class B
Harmonic Current EmissionsEN 61000-3-2, Class A
Voltage Fluctuation and FlickerEN 61000-3-3
ESD ImmunityEN 61000-4-2, level 4, 8 kV contact, 15 kV air
Radiated ImmunityEN 61000-4-3, level 3, 12 V/m
EFTEN 61000-4-4, level 4, ±2 kV
SurgeEN 61000-4-5, level 4, 1 kV DM, 2 kV CM
Conducted ImmunityEN 61000-4-6, level 3, 10 Vrms
Magnetic FieldEN 61000-4-8, level 3, 10 A/m
Voltage DipsEN 61000-4-11, 30%, 20 ms - R&D / EN 61000-4-11, 60%, 100 ms / EN 61000-4-11, 100%, 500 ms / EN 60601-1-2:2015 (4th edition), 30%, 500 ms / EN 60601-1-2:2015 (4th edition), 60%, 100 ms / EN 60601-1-2:2015 (4th edition), 100%, 20 ms / EN 60601-1-2:2015 (4th edition), 100%, 5000 ms

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.