Automation, Drives & PLC
Drives, controllers, panel meters, relays and accessories for control panels and machines. Choose a category, or send us your panel requirement and we will suggest suitable models.
All products in Automation, Drives & PLC
-
Enquire about Proton NETS STP
Proton NETS STP NETS STP Controller
Controller for automatic sewage treatment plant (STP) process control.
-
Enquire about Lutron RSC-801
Lutron RSC-801 8-to-1 RS232 Converter
Converter that combines the RS232 outputs of up to 8 Lutron meters into one RS232 port, for multi-meter logging with SW-U801 or SW-808 software.
-
Enquire about JiGO JG-GP18-10(30)
JiGO JG-GP18-10(30) Photoelectric Sensor, 18 mm, Diffuse / Through Beam
Jigo JG-GP18-10(30) photoelectric sensor, 18 mm, diffuse / through beam, IP67, for detecting objects and levels on machines and conveyors.
-
Enquire about Kusam Meco TDA(C)
Kusam Meco TDA(C) AC Current Transducer, Compact
Isolated AC current transducer: 0 – 1, 0 – 5, 0 – 10 A or dual 1 / 5 A input to 4 – 20 mA, 0 – 20 mA or 0 – 10 V DC output, ≤ 400 ms, DIN rail. Class 0.2%.
-
Enquire about Autonics ATM4-55S
Autonics ATM4-55S W 21.5 × H 28 mm Analog Timer ATM4-55S
Autonics ATM4-55S W 21.5 × H 28 mm analog timer (ATM Series): Relay output, 220 VAC 50 / 60 Hz supply. Order code note: 200-230VAC.
-
Enquire about Selec 800XA
Selec 800XA Analog Timer, 22.5 mm DIN Rail 800XA
Selec 800XA analog timer, 22.5 mm DIN rail: output 2 C/O SPDT, 20 to 240V AC, 12 to 240V DC supply, 22.5mm, DIN rail mount.
-
Enquire about Delta DOP-103BQ
Delta DOP-103BQ Basic Touch Panel HMI 4.3", 480 x 272, 2 COM Ports
Delta DOP-103BQ 4.3-inch basic touch screen HMI (B Type) with 480 x 272 display, Cortex-A8 CPU, 2 serial ports, for machine and panel operator control.
-
Enquire about Rishabh 252-PVZ
Rishabh 252-PVZ Single Phase Under Voltage Relay, Adjustable Time Delay
Single phase AC under voltage relay with user-adjustable time delay up to 10 s and 75 - 100% setpoint, for 57 - 480 V systems; DPDT contacts, auto reset.
-
Enquire about Unison UNI 803 PHT 24 50 420
Unison UNI 803 PHT 24 50 420 Phase Angle Control SSR 803, Slim, Analog Input, 50 A
Slim phase-angle thyristor controller (803 series) that varies the power to 50 A AC loads at 230 or 440 V AC in proportion to a 4-20 mA or 0-10 V DC signal.
-
Enquire about Veritek VIPS 44
Veritek VIPS 44 4-Channel DC Energy Meter
4-channel DC energy meter for shunt inputs (50 – 100 mV, up to 20 kA): current, watts, Wh and Ah, import and export; class 0.5.
-
Enquire about Multispan DMR-162
Multispan DMR-162 Demand Controller
Class 0.5 maximum demand controller and multifunction meter for single and three-phase systems, with THD up to the 32nd order, pulse output and RS-485 Modbus, to keep load within the contract demand.
-
Enquire about Meco DVM72x144533-TRMS
Meco DVM72x144533-TRMS 5-Digit 3-Phase VAR Meter with RS485, TRMS
5-digit (99999 count) 3-phase TRMS digital VAR meter with 25.4 mm display, 3P3W / 3P4W, SMPS supply; RS485 Modbus optional.
-
Enquire about Adi-Artech 60920
Adi-Artech 60920 Side Mount Bending Beam Load Cell
Adi-Artech strain gauge side mount bending beam load cell, 20 Kgf to 50 Kgf for tension and compression, in stainless steel, IP65 sealed. For web tension sensor, force gage, check weigher.
-
Enquire about Minilec D5 MPR1
Minilec D5 MPR1 Motor / Pump Protection Relay
Minilec D5 MPR1 motor / pump protection relay with 2 CO output, for 380 - 440 V AC ± 20%, 45 - 55 Hz. supply. Typical uses: crane motors, AHU fan /pump motors, heavy duty motors.
-
Enquire about EAPL ETR Series
EAPL ETR Series Slim Electronic Timer, 17.5 mm
Ultra-slim 17.5 mm EAPL timer for crowded panels, with finger-guard terminals and an LED that shows timing in progress. Pictured: ETRE-X and ETRCS-X.
-
Enquire about Masibus MAS-AI-U-08-D
Masibus MAS-AI-U-08-D 8 Channel Linearized RTD / TC Input
Masibus MAS-AI-U-08-D 8 channel linearized RTD / TC input: output Voltage / current (Factory set). For reduce cost/channel for RTD / TC input, eliminate ground loop problems.
-
Enquire about Proton OLR 1P
Proton OLR 1P Overload Protection Relay, Single Phase
Protection unit that trips a motor or load on a current fault (Proton OLR 1P). Runs on 230 V AC 1-phase, relay output rated 7 A at 230 V.
-
Enquire about Lutron RSW-914
Lutron RSW-914 Direct WiFi Converter for Lutron RS232 Meters
Converter that shares the readings of one Lutron RS232 meter (up to 12 channels) over WiFi to phone or tablet apps, with no setup needed.
-
Enquire about JiGO JG-GP18M-2S
JiGO JG-GP18M-2S Photoelectric Sensor, 18 mm, Reflector Type
Jigo JG-GP18M-2S photoelectric sensor, 18 mm, reflector type, IP67, for detecting objects and levels on machines and conveyors.
-
Enquire about Kusam Meco TDA3
Kusam Meco TDA3 AC Current Transducer, 3-phase, average to RMS
Isolated 3-phase AC current transducer (average to RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.2%.
-
Enquire about Autonics ATM4-61S
Autonics ATM4-61S W 21.5 × H 28 mm Analog Timer ATM4-61S
Autonics ATM4-61S W 21.5 × H 28 mm analog timer (ATM Series): Relay output, 110 VAC 50 / 60 Hz supply. Order code note: 100-120VAC.
-
Enquire about Selec 800XC
Selec 800XC Analog Timer, 22.5 mm DIN Rail 800XC
Selec 800XC analog timer, 22.5 mm DIN rail: output 2 C/O (DPDT), 20 to 240V AC, 12 to 240V DC supply, 22.5 mm, DIN rail mount.
-
Enquire about Delta DOP-103WQ
Delta DOP-103WQ Advanced Touch Panel HMI 4.3", 480 x 272, 2 COM Ports, Ethernet
Delta DOP-103WQ 4.3-inch advanced touch screen HMI (W Type) with 480 x 272 display, Cortex-A8 CPU, 2 serial ports and 1 Ethernet port, for machine and panel operator control.
-
Enquire about Rishabh 253-EFR
Rishabh 253-EFR Earth Fault Relay
Earth fault relay for CBCT, neutral or summation CTs with 1 A or 5 A secondary: trip setting 10 - 90%, delay 1 - 10 s or instantaneous, manual / remote reset, 230 V AC aux.