Masibus MAS-AI-U-08-D 8 Channel Linearized RTD / TC Input

Brand
Masibus
Model number
MAS-AI-U-08-D

Masibus MAS-AI-U-08-D 8 channel linearized RTD / TC input: output Voltage / current (Factory set). For reduce cost/channel for RTD / TC input, eliminate ground loop problems.

Price and availability on request

Request a quote

Sent with the product details: Masibus MAS-AI-U-08-D 8 Channel Linearized RTD / TC Input.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal input (RTD, thermocouple)
  • 1.5 KV AC RMS Isolation between Input, Output and Power
  • Linearized Output
  • Fast Response time: <500 ms
  • Fully Programmable for Input type & Range
  • Optional Windows mTRAN software for Configuration, Calibration & Monitoring
  • Reverse polarity protection
  • Direct/Reverse output settable
  • Sensor break detection
  • Universal DIN Rail Mounting

Specifications

Input
No. of Channels8 Po
Input typeRTD: PT 100 3-wire (0.1 °C) Fu (Automatic 3 wire compensation) Po TC: E, J, K, T, B, R, S, N (ANSI standard) LE As per table - 1
Input Range
Input Impedance>1M Ω
Input Resolution16 bits Di
Burnout Current for TC<1uA Mo
CJC Error+/-2.0 °C Pro
RTD Excitation Current0.3048 mA Ter
CMRR> 120 dB Ter
NMRR> 40 dB We
Temp Co≤150 PPM
Max I/P Voltage20 V Op TC: 5mV; Pt100: 50 °C Hu
Min Spans
LED IndicationRed LED ON for sensor open status En
Input TerminalsScrew terminals (2.5mm² conductor size)
Output
Output TypeVoltage / current (Factory set)
Sensor Break OutputUpscale or downscale*
Output DirectionDirect or reverse*
Response Time≤ 500ms at full load
Ordering Code Cable Ordering Code
MAS-AI-U-08-DX
Power Supply
wer Supply24VDC ±10%
se Rating2 Amp (Fast blown)
wer Consumption<10VA
D IndicationGreen LED - Healthy status Red LED - Fault status
Physical
mension (in mm)225(L) x 90(W) x 92(D)
untingDIN Rail (35 mm width)
file MaterialPVC
minal BlockUL, CSA standard
minal Cable SizeUpto 2.5mm² conductor
ightApproximately 400 gms.
Environmental
erating Temperature0 to 50 °C
midity30 to 95% RH non-condensing
vironmental ProtectionConformal coating on PCB Table - 1
Input Type Input Range
E-200 to 1000 °C
J-200 to 1200 °C
K-200 to 1370 °C
T-200 to 400 °C
B450 to 1820 °C
R0 to 1750 °C
S0 to 1750 °C
N-200 to 1300 °C
Product
ApplicationsReduce cost/channel for RTD / TC input, Eliminate Ground Loop problems, Protect Expensive control systems against field faults, Isolate and Translate Field Signals, Eliminate Common Mode Voltages, Industrial process control, Factory automation, SCADA and DAS
IndustriesSystem Integrators, Power Stations, Cement Industries, Waste Water Treatment plants, Sugar Industries, Pulp & Paper Industries, Metal Industries

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.